Artigo Produção Nacional Revisado por pares

Electroanalytical Performance of (SiPy+Cl−/CuTsPc)5 LbL Film for Detecting Promethazine Hydrochloride

2011; Wiley; Volume: 23; Issue: 8 Linguagem: Inglês

10.1002/elan.201100202

ISSN

1521-4109

Autores

Cliciane Guadalupe de Jesus, Cristiane Maria Sampaio Forte, Karen Wohnrath, Christiana Andrade Pessôa, Janete E. Soares, Sérgio Toshio Fujiwara, Pedro de Lima‐Neto, Adriana N. Correia,

Tópico(s)

Electrochemical sensors and biosensors

Resumo

Abstract A (SiPy + Cl − /CuTsPc) 5 layer‐by‐layer film was employed for the electroanalytical determination of promethazine hydrochloride in BR buffer pH 5.0 with peaks at 0.48 and 0.79 V. After optimisation of the square‐wave parameters ( f =100 s −1 , a =40 mV and Δ E s =2 mV), the peak at 0.79 V was used for quantification and a detection limit of 8.71×10 −9 mol L −1 and a quantification limit of 9.31×10 −8 were calculated. The applicability of this procedure was tested on commercial formulations of promethazine hydrochloride by observing the stability, specificity, recovery and precision of the procedure in complex samples, without any preliminary treatment.