Osseointegration: a reality
1998; Wiley; Volume: 17; Issue: 1 Linguagem: Inglês
10.1111/j.1600-0757.1998.tb00120.x
ISSN1600-0757
Autores Tópico(s)Orthodontics and Dentofacial Orthopedics
ResumoPeriodontology 2000Volume 17, Issue 1 p. 22-35 Osseointegration: a reality Robert K. Schenk, Robert K. SchenkSearch for more papers by this authorDaniel Buser, Daniel BuserSearch for more papers by this author Robert K. Schenk, Robert K. SchenkSearch for more papers by this authorDaniel Buser, Daniel BuserSearch for more papers by this author First published: 23 February 2007 https://doi.org/10.1111/j.1600-0757.1998.tb00120.xCitations: 177AboutPDF ToolsRequest permissionExport citationAdd to favoritesTrack citation ShareShare Give accessShare full text accessShare full-text accessPlease review our Terms and Conditions of Use and check box below to share full-text version of article.I have read and accept the Wiley Online Library Terms and Conditions of UseShareable LinkUse the link below to share a full-text version of this article with your friends and colleagues. Learn more.Copy URL References 1 Albrektsson T, Brånemark PI, Hansson HA, Lindström J. Osseointegrated titanium implants. Acta Orthop Scand 1981: 52: 155– 170. 2 Babbush CA, Kent JN, Misiek DJ. Titanium plasma-sprayed (TPS) screw implants for the reconstruction of the edentulous mandible. J Oral Maxillofac Surg 1986: 44: 274– 282. 3 Becker W, Becker BE, Israelson H, Lucchini JP, Handelsman M, Ammons W, Rosenberg E, Rose L, Tucker LM, Lekholm U. One-step surgical placement of Brånemark implants. A prospective multicenter clinical study. Int J Oral Maxillofac Implants 1997: 12: 454– 462. 4 Bereiter H, Huggler AH, Jacob HAC. Künstliche Hüftgelenke. Probleme und Fortschritte. Swiss Med 1989: 4: 7– 18. 5 Bernard JP, Belser UC, Martinet JP, Borgis SA. Osseointegration of Brånemark fixtures using a single-step operating system. A preliminary prospective one-year study in the edentulous mandible. Clin Oral Implants Res 1995: 6: 122– 129. 6 Biesbrock AR, Edgerton M. Evaluation of the clinical predictability of hydroxyapatite-coated endosseous dental implants: a review of the literature. Int J Oral Maxillofac Implants 1995: 10: 712– 720. 7 Bobyn JD, Engh CA. Biologic fixation of hip prostheses: review of the clinical status and current concepts. Asv Orthop Surg 1983: 7: 137– 150. 8 Brånemark P-I, Breine U, Adell R, Hansson O, Lindström J Ohlsson Å Intra-osseous anchorage of dental prostheses. I. Experimental studies. Scand J Plast Reconstr Surg Hand Surg 1969: 3: 81– 100. 9 Brånemark P-I, Hansson B-O, Adell R, Breine U, Lindström J, Hallén OÖhman A Osseointegrated implants in the treatment of the edentulous jaw. Experience from a 10-year period. Scand J Plast Reconstr Surg Hand Surg 1977: 11: suppl 16. 10 Buchs AU, Hahn J, Vassos DM. Efficacy of threaded hydroxyapatite-coated implants placed in the anterior mandible. Implant Dent 1995: 4: 272– 275. 11 Buchs AU, Hahn J, Vassos DM. Efficacy of threaded hydroxyapatite-coated implants in the anterior mandible supporting overdentures. Implant Dent 1996: 5: 188– 192. 12 Buser D, Schenk RK, Steinemann S, Fiorellini JP, Fox CH, Stich H. Influence of surface characteristics on bone integration of titanium implants. A histometric study in miniature pigs. J Biomed Mater Res 1991: 25: 889– 902. 13 Buser D, Weber HP, Donath K, Fiorellini JP, Paquette DW, Williams RC. Soft tissue reactions to non-submerged unloaded titanium implant in beagle dogs. J Periodontol 1992: 63: 225– 235. 14 Buser D, Mericske-Stern R, Bernard JP, Behneke A, Behneke N, Hirt HP, Belser UC, Lang NP. Long-term evaluation of non-submerged ITI implants. I. 8-year life table analysis of a prospective multi-center study with 2359 implants. Clin Oral Implants Res 1997: 8: 161– 172. 15 Callaghan JJ. The clinical results and basic science to total hip arthroplasty with porous-coated prostheses. J Bone Joint Surg 1993: 75A: 299– 310. 16 Cameron HU. The results of early clinical trials with a microporous coated metal hip prosthesis. Clin Orthop 1982: 165: 188– 190. 17 Carlsson L, Röstlund T, Albrektsson B, Albrektsson T. Removal torques for polished and rough titanium implants. Int J Oral Maxillofac Surg 1988: 3: 21– 24. 18 Carr AB, Beals DW, Larsen PE. Reverse-torque failure of screw-shaped implants in baboons after 6 months of healing. Int J Oral Maxillofac Implants 1997: 12: 598– 603. 19 Claes L, Hutzschenreuter P, Pohler O. Lösemomente von Corticalisschrauben in Abhängigkeit von Implantationszeit und Oberflächenbeschaffenheit. Arch Orthop Unfall-Chir 1976: 85: 155– 159. 20 Cochran DL, Schenk RK, Lussi A, Higginbottom FL, Buser D. Bone response to unloaded and loaded titanium implants with a sandblasted and acid-etched surface. A histometric study in the canine mandible. J Biomed Mater Res (in press). 21 Cook SD, Thomas KA, Dalton JE, Volkman TK, Whitecloud TS, Kay JF. Hydroxylapatite coating of porous implants improves bone ingrowth and interface attachment strength. J Biomed Mater Res 1992: 26: 989– 1001. 22 Ericsson I, Randow K, Glantz PO, Lindhe J, Nilner K. Clinical and radiographical features of submerged and nonsubmerged titanium implants. Clin Oral Implants Res 1994: 5: 185– 189. 23 Ericsson I, Nilner K, Klinge, B, Glantz, PO Radiographical and histological characteristics of submerged and nonsubmerged titanium implants. An experimental study in the labrador dog. Clin Oral Implants Res 1996: 7: 20– 26. 24 Frost HM. Micropetrosis. J Bone Joint Surg 1960: 42A: 144– 150. 25 Frost HM. Bone remodeling dynamics. Springfield , IL : CC Thomas, 1963. 26 Frost HM. Bone dynamics in osteoporosis and osteomalacia. Springfield , IL CC Thomas, 1966. 27 Gasser AR, Makek M, Strub JR. Histologische Untersuchungen der Grenzflächen zwischen Knochen und zwei oralen Implantaten beim Menschen. Schweiz Monatsschr Zahnheilkd 1982: 92: 10– 17. 28 Gotfredsen K, Rostrup E, HjØrting-Hansen E, Stoltze K, Budtz-Jörgensen E. Histological and histomorphometrical evaluation of tissue reactions adjacent to endosteal implants in monkeys. Clin Oral Implants Res 1991: 2: 30– 37. 29 Gotfredsen K, Nimb L, HjØrting-Hansen E, Jensen JS, Holmen A. Histomorphometric and removal torque analysis for smooth and TiO2-blasted titanium implants in dogs. Clin Oral Implants Res 1992: 3: 77– 84. 30 Gotfredsen K, Wennerberg A, Johansson C, Skovgaard LT, HjØrting-Hansen E. Anchorage of TiO2-blasted, HA-coated, and machined implants: an experimental study with rabbits. J Biomed Mater Res 1995: 29: 1223– 1231. 31 Jaffin RA, Berman CL. The excessive loss of Brånemark fixtures in type IV bone: a 5-year analysis. J Periodontol 1991: 62: 2– 4. 32 Jemt T. Implant treatment in resorbed edentulous upper jaws. A three-year follow-up study in 70 patients. Clin Oral Implants Res 1993: 4: 187– 194. 33 Jemt T, Chai J, Harnett J, Heath MR, Hutton JE, Johns RB, McKenna S, McNamara DC, Van Steenberghe D, Taylor R, Watson RM, Hermann I. A 5-year prospective multicenter follow-up report on overdentures supported by osseointegrated implants. Int J Oral Maxillofac Implants 1996: 11: 291– 298. 34 Johansson C, Albrektsson T. Integration of screw implants in the rabbit: a 1-yr follow-up of removal torque of titanium implants. Int J Oral Maxillofac Implants 1987: 2: 69– 75. 35 Johnson BW. HA-coated dental implants: long-term consequences. Symposium 1992: 20: 33– 41. 36 Ledermann PD, Kallenberger A, Rahn BA. Analyse eines dreijährigen Implantatfalls. III. Histologie. Quintessenz Zahnärztl Lit 1985: 3: 25– 35. 37 Ledermann PD. Über 20jährige Erfahrung mit der sofortigen funktionellen Belastung von Implantatstegen in der regio interforaminalis. Z Zahnärztl Implantol 1996: 12: 123– 136. 38 Ledermann PD, Schenk RK, Buser D. Longlasting osseointegration of immediately loaded, bar-connected TPS screws after 12 years of function. A histologic case report of a 95-year-old patient. Int J Periodontics Restorative Dent (in press). 39 Listgarten MA, Lang NP, Schroeder HE, Schroeder A. Periodontal tissues and their counterpart around endosseous implants. Clin Oral Implants Res 1991: 21: 1– 19. 40 Piatelli A, Cosci F, Scarano A, Trisi P. Localized chronic suppurative bone infection as a sequel of peri-implantitis in a hydroxyapatite-coated dental implant. Biomaterials 1995: 16: 917– 920. 41 Quirynen M, Naert I, Van Steenberghe D, Schepers E, Calberson L, Theuniers G, Ghyselen J, de Mars G. The cumulative failure rate of the Brånemark system in the overdenture, the fixed partial, and the fixed full prostheses design: a prospective study on 1273 fixtures. J Head Neck Pathol 1991: 10: 43– 53. 42 Schenk RK, Wehrli U. Zur Reaktion des Knochens auf eine zementfreie SL-Femur-Revisionsprothese. Orthopade 1989: 18: 454– 462. 43 Schenk RK. Biology of fracture repair. In: PG Traften, ed. Philadelphia : Saunders, 1992: 31– 75. 44 Schenk RK, Felix R, Hofstetter W. Morphology of connective tissue: Bone. In: E Steinmann, ed. Connective tissue and its heritable disorders. New York : Wiley-Liss, 1993: 85– 101. 45 Schenk RK. Bone regeneration: Biologic basis. In: RK Schenk, ed. Guided bone regeneration in implant dentistry. Carol Stream , IL : Quintessence Publishing Co., 1994: 49– 100. 46 Schenk RK. Osseointegration of sulmesh coatings. In: EW Morscher, ed. Endoprosthetics. Berlin : Springer-Verlag, 1995: 60– 71. 47 Schroeder A, Pohler O, Sutter F. Gewebereaktion auf ein Titan-Hohlzylinderimplantat mit Titan-Spritzschichtoberfläche. Schweiz Monatsschr Zahnheilkd 1976: 86: 713– 727. 48 Schroeder Avan der Zypen E, Stich H, Sutter F. The reaction of bone, connective tissue and epithelium to endosteal implants with sprayed titanium surfaces. J Maxillofac Surg 1981: 9: 15– 25. 49 Steinemann S. The properties of titanium. In: G Krekeler, ed. Oral implantology. Basics, ITI Dental Implant System. 2nd edn. New York : Thieme Medical Publishers, 1996: 37– 59. 50 Strunz V, Gross UM. Histologische Untersuchungen an einem belasteten intramobilen Zylinderimplantat. Dtsch Z Mund Kiefer-Gesichts-Chir 1982: 2: 129– 135. 51 Thomas KA, Kay JF, Cook SD, Jarcho M. The effect of surface macrotexture and hydroxylapatite coating on the mechanical strengths and histologic profiles of titanium implant materials. J Biomed Mater Res 1987: 21: 1395– 1414. 52 Weber HP, Buser D, Donath K, Fiorellini JP, Doppalapudi V, Paquette DW, Williams RC. Comparison of healed tissues adjacent to submerged and non-submerged unloaded titanium dental implants. A histometric study in beagle dogs. Clin Oral Implants Res 1996: 7: 11– 19. 53 Weehler SL. Eight-year clinical retrospective study of titanium plasma-sprayed and hydroxyapatite-coated cylinder implants. Int J Oral Maxillofac Implants 1996: 11: 340– 350. 54 Wennerberg A, Albrektsson T, Andersson B, Krol JJ. A histometric and removal torque study on screw-shaped titanium implants with three different surface topographies. Clin Oral Implants Res 1995: 6: 24– 30. 55 Wennerberg A, Albrektsson T, Lausmaa J. A torque and histomorphometric evaluation of c.p. titanium screws, blasted with 25 and 75 μm sized particles of Al2O3. J Biomed Mater Res 1996: 30: 251– 260. 56 Wennerberg A, Ektessabi A, Albrektsson T, Johansson C, Andersson B. A 1-year follow-up of implants of differing surface roughness placed in rabbit bone. Int J Oral Maxillofac Implants 1997: 12: 486– 494. 57 Wilke HJ, Claes L, Steinemann S. The influence of various titanium surfaces on the interface shear strength between implants and bone. In: AJC Lee, ed. Clinical implant materials. Advances in Biomaterials, Vol. 9. Amsterdam , Elsevier Science Publishers, 1990: 309– 314. 58 Wong M, Eulenberger J, Schenk RK, Hunziker E. Effect of surface topography on the osseointegration of implant materials in trabecular bone. J Biomed Mater Res 1995: 29: 1567– 1575. Citing Literature Volume17, Issue1June 1998Pages 22-35 ReferencesRelatedInformation
Referência(s)