Artigo Revisado por pares

Determination of trace Cd, Cu, Fe, Pb and Zn in diesel and gasoline by inductively coupled plasma mass spectrometry after sample clean up with hollow fiber solid phase microextraction system

2014; Elsevier BV; Volume: 98; Linguagem: Inglês

10.1016/j.sab.2014.06.001

ISSN

1873-3565

Autores

Philiswa N. Nomngongo, Jane Catherine Ngila,

Tópico(s)

Ion-surface interactions and analysis

Resumo

This study reports a simple and efficient method for the determination of trace Cd, Cu, Fe, Pb and Zn in diesel and gasoline samples by inductively coupled plasma mass spectrometry after matrix removal and analyte pre-concentration using hollow fiber-solid phase microextraction (HF–SPME). The optimization of HF-SPME procedure was carried out using two-level full factorial and central composite designs. Four factors (variables), that are, sample solution pH, acceptor phase amount, extraction time and eluent concentration were optimized. Under the optimized experimental conditions, the precision was ≤ 3% (C = 10 μg L− 1, n = 15), limits of detection and quantification ranged from 0.1 to 0.3 μg L− 1 and 0.3–0.9 μg L− 1, respectively, and the maximum preconcentration factor was 30. The HF-SPME method was applied for the determination of trace metals in real gasoline and diesel samples.

Referência(s)