Artigo Revisado por pares

Characterization of SU-8 for electrokinetic microfluidic applications

2005; Royal Society of Chemistry; Volume: 5; Issue: 8 Linguagem: Inglês

10.1039/b503016a

ISSN

1473-0197

Autores

Tiina Sikanen, Santeri Tuomikoski, Raimo A. Ketola, Risto Kostiainen, Sami Franssila, Tapio Kotiaho,

Tópico(s)

Electrowetting and Microfluidic Technologies

Resumo

The characterization of SU-8 microchannels for electrokinetic microfluidic applications is reported. The electroosmotic (EO) mobility in SU-8 microchannels was determined with respect to pH and ionic strength by the current monitoring method. Extensive electroosmotic flow (EOF), equal to that for glass microchannels, was observed at pH ≥4. The highest EO mobility was detected at pH ≥7 and was of the order of 5.8 × 10−4 cm2 V−1 s−1 in 10 mM phosphate buffer. At pH ≤3 the electroosmotic flow was shown to reverse towards the anode and to reach a magnitude of 1.8 × 10−4 cm2 V−1 s−1 in 10 mM phosphate buffer (pH 2). Also the zeta-potential on the SU-8 surface was determined, employing lithographically defined SU-8 microparticles for which a similar pH dependence was observed. SU-8 microchannels were shown to perform repeatably from day to day and no aging effects were observed in long-term use.