Titanium — the material of choice?
1998; Wiley; Volume: 17; Issue: 1 Linguagem: Inglês
10.1111/j.1600-0757.1998.tb00119.x
ISSN1600-0757
Autores Tópico(s)Dental materials and restorations
ResumoPeriodontology 2000Volume 17, Issue 1 p. 7-21 Titanium — the material of choice? Samuel G. Steinemann, Samuel G. SteinemannSearch for more papers by this author Samuel G. Steinemann, Samuel G. SteinemannSearch for more papers by this author First published: 23 February 2007 https://doi.org/10.1111/j.1600-0757.1998.tb00119.xCitations: 279AboutPDF ToolsRequest permissionExport citationAdd to favoritesTrack citation ShareShare Give accessShare full text accessShare full-text accessPlease review our Terms and Conditions of Use and check box below to share full-text version of article.I have read and accept the Wiley Online Library Terms and Conditions of UseShareable LinkUse the link below to share a full-text version of this article with your friends and colleagues. Learn more.Copy URL Share a linkShare onEmailFacebookTwitterLinkedInRedditWechat References 1 Albrektsson T, Brånemark PI, Hansson HA, Lindström J. Osseointegrated titanium implants. Acta Orthop Scand 1981: 52: 155–170. 2 Albrektsson T, Hansson HA, Ivarsson B. Interface analysis of titanium and zirconium bone implants. Biomaterials 1985: 6: 97–101. 3 Atkins PW, Beran JA. General chemistry. New York : Scientific American Books. 1992: 887–917. 4 Baes CF, Mesmer RE. The hydrolysis of cations. New York : John Wiley & Sons, 1976. 5 Boehm HP. Acidic and basic properties of hydroxylated metal oxide surfaces. Disc Faraday Soc 1971: 52: 264–275. 6 T Albrektsson, ed. Tissue-integrated prostheses. Osseo-integration in clinical dentistry. Carol Stream , IL : Quintessence Publishers, 1985: 11–76, 129–143. 7 Brunski JB. Biomechanics of dental implants: future research directions. J Dent Educ 1988: 52: 775–787. 8 Brunski JB, Skalak R. Biomechanical considerations. In: PI Brånemark, ed. Advanced osseointegration surgery: applications in the maxillofacial region. Carol Stream , IL : Quintessence Publishers, 1992: 15–39. 9 Cornell RM, Posner AM, Quirk JP. A titrimetric and electrophoretic investigation of the PZC and the IEP of pigment rutile. J Colloid Interface Sci 1975: 53: 6–13. 10 Curtis ASG, Forrester JV, Clark P. Substrate hydroxylation and cell adhesion. J Cell Sci 1986: 86: 9–24. 11 Ernst KH, Christmann K. The interaction of glycine with a platinum (III) surface. Surface Sci 1989: 222: 277–310. 12 Frey N, Buchillier T, Lê VD, Steinemann SG. Properties of surface oxides on titanium. In: I Caplan, ed. Titanium 92 Science and Technology. Warrendale , PA : Minerals, Metals & Materials Society, 1993: 2135–2141. 13 Gerber HW, Moosmann A, Steinemann S. Bioactivity of metals – tissue tolerance of soluble or solid metal, tested on organ cultured embryonic bone rudiments. In: HG Willert, ed. Technical principles, design and safety of joint implants. Seattle : Hogrefe & Huber, 1994: 248–254. 14 Gisler A. Die Adsorption von Aminosäuren an Grenzflächen Oxyd-Wasser Dissertation. Berne : University of Berne, 1981. 15 Gold JM, Schmidt M, Steinemann SG. XPS study of amino acid adsorption to titanium surfaces. Helv Phys Acta 1989: 62: 246–249. 16 Gold JM, Schmidt M, Steinemann SG. XPS study of retrieved titanium and Ti alloy implants. In: AJC Lee, ed. Clinical implant materials. Amsterdam : Elsevier Science Publishers, 1990: 69–74. 17 Gotfredsen K, Nimb L, Hjörting-Hansen E, Jensen JS, Holmen A. Histomorphometric and removal torque analysis for TiO2-blasted titanium implants. An experimental study on dogs. Clin Oral Implants Res 1992: 3: 77–84. 18 Gwynn Iolo AP Cell biology at interfaces. J Mater Sci Mater Med 1994: 5: 357–360. 19 Hanawa T, Asaoka K, Ukai H, Murakami K. Calcium phosphate precipitation on titanium in electrolyte and its acceleration by calcium-ion-implantation. In: NS Istephanous, ed. Compatibility of biomedical implants. Corrosion and organic and biological electrochemistry divisions. Proc Vol. 94–15. Pennington , NJ : The Electrochemical Society, 1994: 126–137. 20 Hillmann G, Donath K. Licht- und elektronenmikroskopische Untersuchung zur Biostabilität dentaler Titanimplantate. Z Zahnärztl Implantol 1991: 7: 170–177. 21 Johansson C, Jacobsson M, Albrektsson T. Removal forces for osseointegrated titanium implants. In: K Groot, ed. Implant materials in biofunction: advances in biomaterials. Amsterdam: Elsevier Science Publishers 1988: 8: 87–92. 22 Johansson CB, Albrektsson T, Thomsen P. Removal torques of screw-shaped c.p. titanium and Ti6Al4V implants in rabbit bone. In: AJC Lee, ed. Clinical implant materials: advances in biomaterials. Amsterdam: Elsevier Science Publishers 1990: 9: 87–92. 23 Johansson CB, Hansson HA, Albrektsson T. Qualitative interfacial study between bone and tantalum, niobium or commercially pure titanium. Biomaterials 1990: 11: 277–280. 24 Johansson CB, Sennerby L, Albrektsson T. A removal torque and histomorphometric study of bone tissue reactions to commercially pure titanium and vitallium implants. Int J Oral Maxillofac Implants 1991: 6: 437–441. 25 Johansson CB, Albrektsson T. A removal torque and histomorphometric study of commercially pure niobium and titanium implants in rabbit bone. Clin Oral Implants Res 1991: 2: 24–29. 26 Johansson CB, Wennerberg A, Albrektsson T. Quantitative comparison of screw-shaped commercially pure titanium and zirconium implants in rabbit tibia. J Mater Sci Mater Med 1994: 5: 340–344. 27 Kothari S, Hatton PV, Douglas CWI. Protein adsorption to titanium surfaces. J Mater Sci Mater Med 1995: 6: 695–698. 28 Lehninger AL. Biochemistry. New York : Worth Publishers, 1975. 29 Leventhal GS. Titanium, a metal for surgery. J Bone Joint Surg 1951: 33A: 473. 30 Linder L, Alberktsson T, Brånemark PI, Hansson HA, Ivarsson B, Jönsson U, Lundström I. Electron microscopic analysis of the bone-titanium interface. Acta Orthop Scand 1983: 54: 45–52. 31 Listgarten MA, Buser D, Steinemann SG, Donath K, Lang NP, Weber HP. Light and transmission electron microscopy of the intact interfaces between non-submerged titaniumcoated epoxy resin implants and bone or gingiva. J Dent Res 1992; 71: 364–371. 32 Luckey TD, Venugopal B. Metal toxicity in mammals. Physiological and chemical basis. New York: Plenum Press 1977: 1: 103–128. 33 Maurer AM, Lê VD, Steinemann SG, Guenther H, Bille J. Surface chemistry and cell reactions. 10th Eur Conf Biomaterials. Davos : in press. 34 Mäusli PA, Bloch PR, Geret V, Steinemann SG. Surface characterisation of titanium and Ti-alloys. In: AJC Lee, ed. Biological and biomechanical performance of biomaterials. Amsterdam : Elsevier Science Publishers, 1986: 57–62. 35 Mäusli PA, Steinemann SG, Simpson JP. Properties of surface oxides on titanium and some titanium alloys. In: G Béranger, ed. 6th World Conference on Titanium. Les Ulis : Les éditions de physique, 1988: 1759–1764. 36 Mericske-Stern R, Geering AH, Bürgin WB, Graf H. Three-dimensional force measurements on mandibular implants supporting overdentures. Int J Oral Maxillofac Implants 1992: 7: 185–194. 37 Mericske-Stern R, Assal P, Buergin W. Simultaneous force measurements in 3 dimensions on oral endosseous implants in vitro and in vivo. Clin Oral Implants Res 1996: 7: 378–386. 38 Mericske-Stern R, Piotti M, Sirtes G. 3-D in vivo force measurements on mandibular implants supporting overdentures. Clin Oral Implants Res 1996: 7: 387–396. 39 Parfitt GD. The surface of titanium dioxide. Progr Surface Membr Sci 1976: 11: 181–226. 40 Parks GA. The isoelectric points of solid oxides, solid hydroxides, and aqueous hydroxo complex systems. Chem Rev 1965: 65: 177–198. 41 Patthey L. Photoelectron diffraction and photoemission studies of some semiconductor and oxide surfaces. PhD thesis. Lausanne : University of Lausanne, 1995. 42 Pierschbacher MD, Ruoslahti E. Cell attachment activity of fibronectin can be duplicated by small synthetic fragments of the molecule. Nature 1984: 309: 30–33. 43 Pourbaix M, de Zoubov N, Van Muylder J, Deltombe E, Schmets J, van Leugenhaghe C, Moussard M, Besson J, Brenet JP, Burgers WG, Charlot G, Carrels RM, Hoar TP, Jolas F, Kunz W, Maraghini M, Piontelli R, Schwabe K, Valensi G, Van Rysselberche P, Pitman AL. Atlas d'équilibres électrochimiques. Paris : Gauthier-Villars, 1963. 44 Pröbster L, Voigt C, Fuhrmann G, Gross VM. Tensile and torsional shear strength of the bone implant interface of titanium implants in the rabbit. J Mater Sci Mater Med 1994: 5: 314–319. 45 Reilly RT, Burstein AH. The elastic and ultimate properties of compact bone tissue. J Biomech 1975: 8: 393–405. 46 Ruoslahti E, Hayman EG, Pierschbacher MD. Extracellular matrices and cell adhesion. Arteriosclerosis 1985: 5: 581–594. 47 Schindler PW. Surface complexation. In: H Sigel, ed. Metal ions in biological systems. New York: Dekker 1984: 18: 105–135. 48 Schindler PW. Co-adsorption of metal ions and organic ligands: formation of ternary surface complexes. In: AF White, ed. Mineral-water interface geochemistry. Reviews in mineralogy. Washington, DC: Mineralogical Society of America 1990: 23: 281–307. 49 Shelton JC, Loukota RA. Pull-out strength of screws from cortical bone in the maxillofacial region. J Mater Sci Mater Med 1996: 7: 231–235. 50 Somasundaran P, Wang YHC. Surface chemical characteristics and adsorption properties of apatite. In: DN Misra, ed. Adsorption on and surface chemistry of hydroxyapatite. New York : Plenum Press, 1984: 129–149. 51 Steflik DE, Sisk AL, Parr GR, Lake RT, Hanes PJ, Berkery DJ, Brewer P. Transmission electron and high-voltage electron microscopy of osteocyte cellular processes extending to the dental implant surface. J Biomed Mater Res 1994: 28: 1095–1107. 52 Steinemann SG. Corrosion of titanium and titanium alloys for surgical implants. In: W Bunk, ed. Proc 5th Int Conf Titanium. Oberursl : Deutsche Ges Metallk, 1985: 1373–1379. 53 Steinemann SG, Perren SM. Titanium alloys as metallic biomaterials. In: W Bunk, ed. Proc 5th Int Conf Titanium. Oberursl : Deutsche Ges Metallk, 1985: 1327–1334. 54 Steinemann SG, Eulenberger J, Maeusli PA, Schroeder A. Adhesion of bone to titanium: biological and biomechanical performance of biomaterials. In: AJC Lee, ed. Advances in biomaterials. Amsterdam: Elsevier Science Publishers 1986: 6: 409–414. 55 Steinemann SG, Mäusli PA. Titanium alloys for surgical implants – biocompatibility from physicochemical principles. Proc 6th World Conf Titanium. In: G Béranger, ed. Les Ulis : Les éditions de physique, 1988: 535–540. 56 Steinemann SG. Tissue compatibility of metals from physicochemical principles. In: NS Istephanous, ed. Compatibility of biomedical implants. Corrosion and organic and biological electrochemistry divisions. Proc Vol. 94–15. Pennington , NJ : The Electrochemical Society, 1994: 1–13. 57 Sukenik CN, Balachander N, Culp LA, Lewandowska K, Merritt K. Modulation of cell adhesion by modification of titanium surfaces with covalently attached self-assembled monolayers. J Biomed Mater Res 1990: 24: 1307–1323. 58 Taylor JL, Brunski JB, Hoshaw SJ, Cochran GVB, Higuchi KW. Interfacial bond strengths of Ti6Al4V and hydroxyapatite-coated Ti6Al4V implants in cortical bone. In: DE Tolman, ed. Tissue Integration in Oral, Orthopedic and Maxillofacial Reconstruction. Proc 2nd Intern Congr Tissue Integration. Carol Stream , IL : Quintessence Publishers Co., 1992: 125–132. 59 Thomsen P, Larsson C, Ericsson LE, Sennerby L, Lausmaa J, Kasemo B. Structure of the interface between rabbit cortical bone and implants of gold, zirconium and titanium. J Mater Sci Mater Med 1997: 8: 653–665. 60 Wennerberg A, Albrektsson T, Andersson B. An animal study of c.p. titanium screws with different surface topographies. J Mater Sci Mater Med 1995: 6: 302–309. 61 Wennerberg A, Albrektsson T, Lausmaa J. Torque and histomorphometric evaluation of c.p. titanium screws blasted with 25 and 75 μm sized particles of Al2O3. J Biomed Mater Res 1996: 30: 251–260. 62 Wilke HJ, Claes L, Steinemann S. The influence of various titanium surfaces on the interface shear strength between implants and bone. In: AJC Lee, ed. Clinical implant materials, Advances in Biomaterials, vol. 9. Amsterdam : Elsevier Science Publishers 1990: 309–314. 63 Wirz UE. Die Adsorption proteinogener Aminosäuren an TiO2 (Anatas). Dissertation University of Berne 1984. 64 Wong M, Eulenberger J, Schenk R, Hunziker E. Effect of surface topology on the osseointegration of implant materials in trabecular bone. J Biomed Mater Res 1995: 29: 1567–1575. Citing Literature Volume17, Issue1June 1998Pages 7-21 ReferencesRelatedInformation
Referência(s)