Artigo Revisado por pares

Hybrid electron cyclotron emission imaging array system for Texas experimental tokamak upgrade

1997; American Institute of Physics; Volume: 68; Issue: 1 Linguagem: Inglês

10.1063/1.1147614

ISSN

1527-2400

Autores

R. P. Hsia, B. H. Deng, W. R. Geck, Liang Cheng, C. W. Domier, Neville C. Luhmann, D. L. Brower, G. Cima,

Tópico(s)

Superconducting Materials and Applications

Resumo

A novel wide bandwidth, low-cost, 20 channel hybrid Schottky diode mixer array-based imaging system has been developed, tested and implemented for electron cyclotron emission diagnostics on the Texas experimental tokamak upgrade (TEXT-U). The array has been successfully utilized to measure 1D and 2D electron temperature profiles, to study sawteeth and magnetohydrodynamic phenomena, and to make measurements of the poloidal/radial correlation lengths and wave-number spectra of electron temperature fluctuations. Fabrication and laboratory characterization results are presented, together with details and test results from the actual implementation on TEXT-U.

Referência(s)
Altmetric
PlumX