Artigo Revisado por pares

Microemulsion determination of lead and cadmium in Saudi Arabian petroleum products by inductively coupled plasma mass spectrometry (ICP/MS)

1994; Elsevier BV; Volume: 145; Issue: 1-2 Linguagem: Inglês

10.1016/0048-9697(94)90306-9

ISSN

1879-1026

Autores

Hassan M. Al-Swaidan,

Tópico(s)

Heavy metals in environment

Resumo

The concentrations of lead and cadmium were determined in Saudi Arabian petroleum products by inductively coupled plasma mass spectrometry (ICP/MS). A microemulsion procedure was used for sample pretreatments while the standard addition method was used for sample analysis. Detection limits were 0.006–0.160 μg/g lead and 0.015–0.170 μg/g cadmium in petroleum product samples. Recoveries of added lead and cadmium as oil soluble salts were made and found to be in the 99–103% and 100–101%) ranges, respectively. The mean lead and cadmium levels in aviation turbine oil were 0.16 and 0.17 μg/g, and in diesel fuel oil were 0.35 and 0.01 μg/g, respectively whereas in leaded motor gasoline, the concentrations were 901.00 and 0.085 μg/g, respectively. The percentage relative standard deviations for five replicate samples were < 5% in all cases. The results are discussed in relation to the sources of the metals, and the possible environmental impact and health risks.

Referência(s)