The prediction of intraocular pressure rise following argon laser trabeculoplasty
1987; Springer Nature; Volume: 1; Issue: 5 Linguagem: Inglês
10.1038/eye.1987.88
ISSN1476-5454
AutoresS J Keightley, Peng T. Khaw, A R Elkington,
Tópico(s)Corneal surgery and disorders
ResumoForty-five patients with poorly controlled chronic open angle glaucoma underwent pneumotonography immediately prior to argon laser trabeculoplasty. The coefficient of facility of outflow (c-value) was calculated from the pneumotonography and correlated with the intraocular pressure rise one hour after the argon laser trabeculoplasty. It appeared that there was a strong relationship between a low c-value indicating a poor outflow facility and a large intraocular pressure rise following argon laser trabeculoplasty. The implications of being able to predict the intraocular pressure rise after argon laser trabeculoplasty are discussed.
Referência(s)