Value of Mitral Valve Tenting Volume Determined by Real-Time Three-Dimensional Echocardiography in Patients With Functional Mitral Regurgitation
2006; Elsevier BV; Volume: 98; Issue: 8 Linguagem: Inglês
10.1016/j.amjcard.2006.05.036
ISSN1879-1913
AutoresJong‐Min Song, Shota Fukuda, Takashi Kihara, Mi‐Seung Shin, Mario J. García, James D. Thomas, Takahiro Shiota,
Tópico(s)Mechanical Circulatory Support Devices
ResumoThis study sought to evaluate mitral valve tenting volume (TnV) as a clinical parameter using real-time 3-dimensional echocardiography in patients with functional mitral regurgitation (MR). In 27 patients with functional MR and 4 controls without mitral disease, real-time 3-dimensional echocardiographic images were obtained to measure TnV frame by frame from presystole to end-systole. The maximal and minimal TnVs during systole were identified in each patient, and mitral annular areas and tenting heights were also measured. Using 2-dimensional echocardiography, tenting area (TnA) was measured from the apical long-axis, apical 4-chamber, and apical 2-chamber views. The regurgitant orifice area was measured by the proximal isovelocity surface area method. Maximal and minimal TnVs occurred at the time of 2 ± 6% and 78 ± 6% of whole systolic duration, respectively, and the systolic percentage change of TnV was related to that of tenting height but not to that of mitral annular area. TnA on the long-axis images was significantly larger than that on the 4- and 2-chamber images (2.5 ± 1.4 vs 1.7 ± 1.3 and 1.9 ± 1.4 cm2, respectively, p <0.001). Regurgitant orifice area was significantly correlated with maximal TnV (r = 0.90), minimal TnV (r = 0.86), and TnA on the long-axis (r = 0.79), 4-chamber (r = 0.75), and 2-chamber (r = 0.73) images. Among minimal TnV and 3 TnAs, minimal TnV was the only independent determinant of regurgitant orifice area (p <0.001). Minimal TnV ≥3.90 ml identified significant functional MR with a sensitivity of 86% and a specificity of 100%. In conclusion, TnV derived from real-time 3-dimensional echocardiography is a preferable novel single index for assessing mitral valve tethering in functional MR to TnA that is dependent on the location of 2-dimensional planes. This study sought to evaluate mitral valve tenting volume (TnV) as a clinical parameter using real-time 3-dimensional echocardiography in patients with functional mitral regurgitation (MR). In 27 patients with functional MR and 4 controls without mitral disease, real-time 3-dimensional echocardiographic images were obtained to measure TnV frame by frame from presystole to end-systole. The maximal and minimal TnVs during systole were identified in each patient, and mitral annular areas and tenting heights were also measured. Using 2-dimensional echocardiography, tenting area (TnA) was measured from the apical long-axis, apical 4-chamber, and apical 2-chamber views. The regurgitant orifice area was measured by the proximal isovelocity surface area method. Maximal and minimal TnVs occurred at the time of 2 ± 6% and 78 ± 6% of whole systolic duration, respectively, and the systolic percentage change of TnV was related to that of tenting height but not to that of mitral annular area. TnA on the long-axis images was significantly larger than that on the 4- and 2-chamber images (2.5 ± 1.4 vs 1.7 ± 1.3 and 1.9 ± 1.4 cm2, respectively, p <0.001). Regurgitant orifice area was significantly correlated with maximal TnV (r = 0.90), minimal TnV (r = 0.86), and TnA on the long-axis (r = 0.79), 4-chamber (r = 0.75), and 2-chamber (r = 0.73) images. Among minimal TnV and 3 TnAs, minimal TnV was the only independent determinant of regurgitant orifice area (p <0.001). Minimal TnV ≥3.90 ml identified significant functional MR with a sensitivity of 86% and a specificity of 100%. In conclusion, TnV derived from real-time 3-dimensional echocardiography is a preferable novel single index for assessing mitral valve tethering in functional MR to TnA that is dependent on the location of 2-dimensional planes.
Referência(s)