Artigo Acesso aberto Revisado por pares

Air pollution studies using PIXE and ICP methods

2006; IOP Publishing; Volume: 41; Linguagem: Inglês

10.1088/1742-6596/41/1/070

ISSN

1742-6596

Autores

Claudia Stihi, Anca Bancuta, I. Popescu, Marian Vîrgolici, V. Cimpoca, M. Gugiu, Gh. Vlaicu,

Tópico(s)

Radioactive contamination and transfer

Resumo

In the present work the moss biomonitoring technique and the combination of two analytical techniques - Particle Induced X-ray Emission (PIXE) [3] and Inductively Coupled Plasma (ICP) [4] - were applied for assessing environmental situation from the point of view of air polluting along the transect from north to south of the Dambovita County. PIXE analysis at the Tandem Accelerator FN-8 of the National Institute of Nuclear Physics - Horia Hulubei of Magurele, Bucharest, allowed determination of P, S, Cl, K, Ca, Mn, Fe, Ni, Cu, Zn, As, Sr, Cd and Pb in samples. ICP analyses were made using a Baird ICP2070 - Sequential Plasma Spectrometer in Targoviste and we determined in samples the concentration of Li, B, Na, and Mg together with Cd and Pb. The obtained results will permit to determine the regional extent of heavy metals and toxic elements atmospheric pollution and to identify specially affected areas and local sources of

Referência(s)