Device-Measured Physical Activity Versus Six-Minute Walk Test as a Predictor of Reverse Remodeling and Outcome After Cardiac Resynchronization Therapy for Heart Failure

2014; Elsevier BV; Volume: 113; Issue: 9 Linguagem: Inglês

10.1016/j.amjcard.2014.01.430

ISSN

1879-1913

Autores

É. Végh, Jagdesh Kandala, Mary Orencole, Gaurav A. Upadhyay, Ajay Sharma, Alexandra Miller, Béla Merkely, Kimberly A. Parks, Jagmeet P. Singh,

Tópico(s)

Muscle activation and electromyography studies

Resumo

Implanted devices can provide objective assessment of physical activity over prolonged periods. The purpose of this study was to investigate the prognostic value of device-measured physical activity data compared with a six-minute walk test (6MWT) in predicting clinical response to cardiac resynchronization therapy (CRT). This was a single-center study in which patients who underwent CRT for standard indications were evaluated. Daily physical activity and 6MWT were evaluated postimplant at 1, 3, and 6 months. The primary end point was a composite of heart failure hospitalization, transplant, left ventricular (LV) assist device, and all-cause death at 3 years. Echocardiographic response, defined as a ≥10% improvement in LV ejection fraction (LVEF), at 6 months was the secondary end point. About 164 patients were included: average age was 67.3 ± 12.9 years, 77% were men, baseline LVEF was 25% ± 7%. Kaplan-Meier curves showed superior freedom from the composite end point in the highest tertile of both 6MWT and physical activity compared with the lowest tertile (41 vs 23 cases, respectively, p <0.001) for 6MWT and for activity (22 vs 7 cases, respectively, p = 0.001). In an adjusted multivariate model, independent predictors of improved clinical outcome included 1-month physical activity (hazard ratio 0.546, 95% confidence interval [CI] 0.361 to 0.824, p = 0.004) and 6MWT (hazard ratio 0.581, 95% CI 0.425 to 0.795, p = 0.001). An additional hour of higher activity at 1 month translated to a 1.38 times (95% CI 1.075 to 1.753, p = 0.011) higher likelihood of improved echocardiographic response. In conclusion, device-based measures of physical activity may be useful in predicting echocardiographic reverse remodeling and long-term clinical outcome in patients receiving CRT. Implanted devices can provide objective assessment of physical activity over prolonged periods. The purpose of this study was to investigate the prognostic value of device-measured physical activity data compared with a six-minute walk test (6MWT) in predicting clinical response to cardiac resynchronization therapy (CRT). This was a single-center study in which patients who underwent CRT for standard indications were evaluated. Daily physical activity and 6MWT were evaluated postimplant at 1, 3, and 6 months. The primary end point was a composite of heart failure hospitalization, transplant, left ventricular (LV) assist device, and all-cause death at 3 years. Echocardiographic response, defined as a ≥10% improvement in LV ejection fraction (LVEF), at 6 months was the secondary end point. About 164 patients were included: average age was 67.3 ± 12.9 years, 77% were men, baseline LVEF was 25% ± 7%. Kaplan-Meier curves showed superior freedom from the composite end point in the highest tertile of both 6MWT and physical activity compared with the lowest tertile (41 vs 23 cases, respectively, p <0.001) for 6MWT and for activity (22 vs 7 cases, respectively, p = 0.001). In an adjusted multivariate model, independent predictors of improved clinical outcome included 1-month physical activity (hazard ratio 0.546, 95% confidence interval [CI] 0.361 to 0.824, p = 0.004) and 6MWT (hazard ratio 0.581, 95% CI 0.425 to 0.795, p = 0.001). An additional hour of higher activity at 1 month translated to a 1.38 times (95% CI 1.075 to 1.753, p = 0.011) higher likelihood of improved echocardiographic response. In conclusion, device-based measures of physical activity may be useful in predicting echocardiographic reverse remodeling and long-term clinical outcome in patients receiving CRT.

Referência(s)