Revisão Revisado por pares

Light-intensity distribution in eccentric photorefraction crescents

1998; Optica Publishing Group; Volume: 15; Issue: 6 Linguagem: Inglês

10.1364/josaa.15.001500

ISSN

1520-8532

Autores

R. Kusel, Ulrich Oechsner, W. Wesemann, Stephan Russlies, Eva M. Irmer, B. Rassow,

Tópico(s)

Optical Coherence Tomography Applications

Resumo

We try to improve the accuracy of eccentric photorefraction by taking more information into account than just the size and tilt of the crescent. Based on Gaussian optics and the assumption of an isotropic scattering retina, a theoretical analysis of the light-intensity distribution in the pupils of astigmatic eyes is presented. The method is applied to different photorefractor setups (point light source, long linear light source, knife-edge aperture, and circular aperture). In the case of a knife-edge aperture the crescent structure can be formulated analytically. In the case of a circular aperture an analytic description is possible only for spherical refractive errors, but astigmatic refractive errors can be determined from crescent parameters with neural networks.

Referência(s)