Artigo Revisado por pares

Boxer Knuckle (Injury of the Extensor Hood with Extensor Tendon Subluxation): Diagnosis with Dynamic US—Report of Three Cases

2003; Radiological Society of North America; Volume: 228; Issue: 3 Linguagem: Inglês

10.1148/radiol.2283020833

ISSN

1527-1315

Autores

Robert Lopez‐Ben, Donald H. Lee, Daniel J. Nicolodi,

Tópico(s)

Foot and Ankle Surgery

Resumo

The use of dynamic ultrasonography (US) in diagnosing traumatic and nontraumatic extensor tendon dislocations in fingers of three subjects is reported. Dynamic US of the clenched fist in two patients with traumatic injury revealed dislocated but grossly intact tendons surrounded by soft-tissue edema; magnetic resonance (MR) imaging in one patient indicated similar findings. Rupture in the sagittal band of the extensor hood mechanism in the two patients was confirmed at surgery. The third subject, an asymptomatic volunteer, had a congenital tendency toward dislocation. Dynamic US of the clenched fist is useful in diagnosing injuries of the extensor hood mechanism. Supplemental material:radiology.rsnajnls.org/cgi/content/full/2283020833/DC1. © RSNA, 2003

Referência(s)