Artigo Revisado por pares

A Prospective Multicenter Study on the Outcome of Type I Collagen Hydrogel–Based Autologous Chondrocyte Implantation (CaReS) for the Repair of Articular Cartilage Defects in the Knee

2011; SAGE Publishing; Volume: 39; Issue: 12 Linguagem: Inglês

10.1177/0363546511423369

ISSN

1552-3365

Autores

Ulrich Schneider, Lars Rackwitz, S. Andereya, Sebastian Siebenlist, Florian Fensky, Johannes Reichert, Ingo Löer, Thomas Barthel, Maximilian Rudert, Ulrich Nöth,

Tópico(s)

Periodontal Regeneration and Treatments

Resumo

The Cartilage Regeneration System (CaReS) is a novel matrix-associated autologous chondrocyte implantation (ACI) technique for the treatment of chondral and osteochondral lesions (Outerbridge grades III and IV). For this technology, no expansion of the chondrocytes in a monolayer culture is needed, and a homogeneous cell distribution within the gel is guaranteed.To report a prospective multicenter study of matrix-associated ACI of the knee using a new type I collagen hydrogel (CaReS).Case series; Level of evidence, 4.From 2003 to 2008, 116 patients (49 women and 67 men; mean age, 32.5 ± 8.9 years) had CaReS implantation of the knee in 9 different centers. On the basis of the International Cartilage Repair Society (ICRS) Cartilage Injury Evaluation Package 2000, the International Knee Documentation Committee (IKDC) score, pain score (visual analog scale [VAS]), SF-36 score, overall treatment satisfaction and the IKDC functional status were evaluated. Patient follow-up was performed at 3, 6, and 12 months after surgery and annually thereafter. Mean follow-up was 30.2 ± 17.4 months (range, 12-60 months). There were 67 defects of the medial condyle, 14 of the lateral, 22 of the patella/trochlea, and 3 of the tibial plateau, and 10 patients had 2 lesions. The mean defect size was 5.4 ± 2.4 cm(2). Thirty percent of the defects were 4 cm(2).The IKDC score improved significantly from 42.4 ± 13.8 preoperatively to 70.5 ± 18.7 (P < .001) at latest follow-up. Global pain level significantly decreased (P < .001) from 6.7 ± 2.2 preoperatively to 3.2 ± 3.1 at latest follow-up. There also was a significant increase of both components of the SF-36 score. The overall treatment satisfaction was judged as very good or good in 88% by the surgeon and 80% by the patient. The IKDC functional knee status was grade I in 23.4%, II in 56.3%, III in 17.2%, and IV in 3.1% of the patients.Matrix-associated ACI employing the CaReS technology for the treatment of chondral or osteochondral defects of the knee is a safe and clinically effective treatment that yields significant functional improvement and improvement in pain level. However, further investigation is necessary to determine the long-term viability and clinical outcome of this procedure.

Referência(s)