Artigo Revisado por pares

Compliance of the respiratory system in newborn infants pre‐ and postsurfactant replacement therapy

1993; Wiley; Volume: 15; Issue: 4 Linguagem: Inglês

10.1002/ppul.1950150408

ISSN

8755-6863

Autores

Edmond Kelly, Heather Bryan, Fred Possmayer, Helena Frndova, Charles A. Bryan,

Tópico(s)

Neuroscience of respiration and sleep

Resumo

Abstract Surfactant administration causes a rapid and dramatic improvement in gas exchange, but paradoxically, studies have failed to show an improvement in the mechanical properties of the lung. We have measured dynamic and static (passive flow‐volume technique) compliance before and after a single dose of bovine lipid extract surfactant in 22 premature infants with RDS. This had no effect on the measured dynamic compliance. In contrast, surfactant significantly increased static compliance from 0.41 ± 0.02 to 0.55 ± 0.04 mL/cm H 2 ,O/kg. This improvement was the result of a substantial recruitment of lung volume after surfactant administration. This led us to reduce ventilator pressures, which produced an increase in both dynamic and static compliance, but did not recruit additional volume. We conclude that surfactant causes a substantial increase in static compliance due to volume recruitment, which is consistent with reports of increase in the measured FRC. However, despite this improvement, the compliance is still below our normal range. © 1993 Wiley‐Liss, Inc.

Referência(s)
Altmetric
PlumX