Resumo

To compare the accuracy of ultrasonography and magnetic resonance imaging in the detection of rotator cuff tears.Ninety-six patients with clinically suspected rotator cuff pathology underwent ultrasonography and magnetic resonance imaging of the shoulder. The findings in 88 patients were compared with arthroscopy or open surgery.Full-thickness tear was confirmed in 57 cases, partial-thickness tear in 30 cases and degenerative changes without tear in 1. In all 57 cases of full-thickness tear and in 28 out of 30 cases of partial-thickness tear the supraspinatus tendon was involved. The accuracy in the detection of full-thickness tears was 98 and 100% for ultrasonography and magnetic resonance imaging, respectively. The accuracy in the detection of bursal or articular partial-thickness tears was 87 and 90% for ultrasonography and magnetic resonance imaging, respectively.In experienced hands ultrasonography should be considered as an accurate modality for the initial investigation of rotator cuff, especially supraspinatus, tears.