Carta Revisado por pares

Multidetector CT in Abdominal Aortic Aneurysm Following Endovascular Repair: How to Consider the Value of a Delayed Phase

2007; Radiological Society of North America; Volume: 245; Issue: 2 Linguagem: Inglês

10.1148/radiol.2452062111

ISSN

1527-1315

Autores

Hicham T. Abada, Jafar Golzarian,

Tópico(s)

Aortic aneurysm repair treatments

Resumo

HomeRadiologyVol. 245, No. 2 PreviousNext CommunicationsLetters to the EditorMultidetector CT in Abdominal Aortic Aneurysm Following Endovascular Repair: How to Consider the Value of a Delayed PhaseHicham T. Abada, Jafar GolzarianHicham T. Abada, Jafar GolzarianAuthor AffiliationsDepartment of Radiology, Section of Vascular and Intervention, University of Iowa Hospitals and Clinics, 200 Hawkins Drive, 3JPP, Iowa City, IA 52242 e-mail: [email protected]Hicham T. AbadaJafar GolzarianPublished Online:Nov 1 2007https://doi.org/10.1148/radiol.2452062111MoreSectionsFull textPDF ToolsImage ViewerAdd to favoritesCiteTrack CitationsPermissionsReprints ShareShare onFacebookTwitterLinked In References1 Iezzi R, Cotroneo AR, Filippone A, et al. Multidetector CT in abdominal aortic aneurysm treated with endovascular repair: are unenhanced and delayed phase enhanced images effective for endoleak detection? Radiology 2006;241(3):915–921. Link, Google Scholar2 Golzarian J, Dussaussois L, Abada HT, et al. Helical CT of aorta after endoluminal stent-graft therapy: value of biphasic acquisition. AJR Am J Roentgenol 1998;171(2):329–331. Crossref, Medline, Google Scholar3 Becker CR, Hong C, Knez A, et al. Optimal contrast application for cardiac 4-detector-row computed tomography. Invest Radiol 2003;38(11):690–694. Crossref, Medline, Google Scholar4 Kalra MK, Maher MM, Toth TL, et al. Strategies for CT radiation dose optimization. Radiology 2004;230(3):619–628. Link, Google Scholar5 Wintersperger B, Jakobs T, Herzog P, et al. Aorto-iliac multidetector-row CT angiography with low kV settings: improved vessel enhancement and simultaneous reduction of radiation dose. Eur Radiol 2005;15(2):334–341. Crossref, Medline, Google ScholarArticle HistoryPublished in print: 2007 FiguresReferencesRelatedDetailsCited ByBest Practice Guidelines: Imaging Surveillance After Endovascular Aneurysm RepairTylerSmith, Keith B.Quencer2020 | American Journal of Roentgenology, Vol. 214, No. 5Identification of Factors Influencing Cumulative Long-Term Radiation Exposure in Patients Undergoing EVARG.Kalender, MilanLisy, U. A.Stock, A.Endisch, A.Kornberger2017 | International Journal of Vascular Medicine, Vol. 2017Endovascular abdominal aortic aneurysm repair: surveillance of endoleak using maximum transverse diameter of aorta on non-enhanced CTHirokiNagayama, EijunSueyoshi, IchiroSakamoto, MasatakaUetani2012 | Acta Radiologica, Vol. 53, No. 6Vascular SurgeryAndrewMisselt, JafarGolzarian2012Dual-Energy CT for Detection of Endoleaks After Endovascular Abdominal Aneurysm Repair: Usefulness of Colored Iodine OverlayGiorgioAscenti, SilvioMazziotti, SalvatoreLamberto, AntonioBottari, SimonaCaloggero, SergioRacchiusa, AchilleMileto, EmanueleScribano2011 | American Journal of Roentgenology, Vol. 196, No. 6ACCF/ACR/AHA/NASCI/SAIP/SCAI/SCCT 2010 Expert Consensus Document on Coronary Computed Tomographic AngiographyDaniel B.Mark, Daniel S.Berman, Matthew J.Budoff, J. JeffreyCarr, Thomas C.Gerber, Harvey S.Hecht, Mark A.Hlatky, John McB.Hodgson, Michael S.Lauer, Julie M.Miller, Richard L.Morin, DebabrataMukherjee, MichaelPoon, Geoffrey D.Rubin, Robert S.Schwartz, Robert A.Harrington, Eric R.Bates, Charles R.Bridges, Mark J.Eisenberg, Victor A.Ferrari, Mark A.Hlatky, Alice K.Jacobs, SanjayKaul, David J.Moliterno, DebabrataMukherjee, Robert S.Rosenson, James H.Stein, Howard H.Weitz, Deborah J.Wesley2010 | Catheterization and Cardiovascular Interventions, Vol. 76, No. 2ACCF/ACR/AHA/NASCI/SAIP/SCAI/SCCT 2010 Expert Consensus Document on Coronary Computed Tomographic AngiographyDaniel B.Mark, Daniel S.Berman, Matthew J.Budoff, J. JeffreyCarr, Thomas C.Gerber, Harvey S.Hecht, Mark A.Hlatky, John McB.Hodgson, Michael S.Lauer, Julie M.Miller, Richard L.Morin, DebabrataMukherjee, MichaelPoon, Geoffrey D.Rubin, Robert S.Schwartz2010 | Journal of the American College of Cardiology, Vol. 55, No. 23Dual-Energy Computed Tomography Imaging of the Aorta After Endovascular Repair of Abdominal Aortic AneurysmShakedLaks, MichaelMacari, HershChandarana2010 | Seminars in Ultrasound, CT and MRI, Vol. 31, No. 4ACCF/ACR/AHA/NASCI/SAIP/SCAI/SCCT 2010 Expert Consensus Document on Coronary Computed Tomographic AngiographyDaniel B.Mark, Daniel S.Berman, Matthew J.Budoff, J. JeffreyCarr, Thomas C.Gerber, Harvey S.Hecht, Mark A.Hlatky, John McB.Hodgson, Michael S.Lauer, Julie M.Miller, Richard L.Morin, DebabrataMukherjee, MichaelPoon, Geoffrey D.Rubin, Robert S.Schwartz2010 | Circulation, Vol. 121, No. 22Endovascular Abdominal Aortic Aneurysm Repair: Nonenhanced Volumetric CT for Follow-up1Thorsten A. Bley, , Peter J. Chase, , Scott B. Reeder, , Christopher J. François, , Kazuhiko Shinki, , Girma Tefera, , Frank N. Ranallo, , Thomas M. Grist, , and Myron Pozniak, 1 October 2009 | Radiology, Vol. 253, No. 1Abdominal Aorta: Evaluation with Dual-Source Dual-Energy Multidetector CT after Endovascular Repair of Aneurysms—Initial Observations1Hersh Chandarana, , Myrna C. B. Godoy, , Ioannis Vlahos, , Anno Graser, , James Babb, , Christianne Leidecker, , and Michael Macari, 1 November 2008 | Radiology, Vol. 249, No. 2Recommended Articles Type II Endoleak Nidus Volume on Arterial and Delayed Phases of Initial CT Angiography after Endovascular Abdominal Aortic Aneurysm Repair Predicts Persistent Endoleak and Aneurysm Sac EnlargementRadiology: Cardiothoracic Imaging2021Volume: 3Issue: 1Contrast-enhanced US Evaluation of Endoleaks after Endovascular Stent Repair of Abdominal Aortic AneurysmRadioGraphics2022Volume: 42Issue: 6pp. 1758-1775Material Separation Using Dual-Energy CT: Current and Emerging ApplicationsRadioGraphics2016Volume: 36Issue: 4pp. 1087-1105Dynamic CT Angiography in Vascular Imaging: Principles and ApplicationsRadioGraphics2022Volume: 42Issue: 7pp. E224-E225Update on Cardiovascular Applications of Multienergy CTRadioGraphics2017Volume: 37Issue: 7pp. 1955-1974See More RSNA Education Exhibits Endoleaks: What the Radiologist Needs to KnowDigital Posters2020Where's The Leak? Contrast Enhanced Ultrasound In Problem Solving Endoleak Detection In Abdominal Aortic Aneurysms Post Endograft Repair. A Multimodality Review.Digital Posters20214D-CT of Endoleaks After Endovascular Aortic Repair: Can Functional-CT Predict Aneurysm Enlargement for Type II Endoleaks?Digital Posters2020 RSNA Case Collection Traumatic posterior tibial artery pseudoaneurysmRSNA Case Collection2021Ductal carcinoma in situRSNA Case Collection2020Unicentric retroperitoneal Castleman's diseaseRSNA Case Collection2021 Vol. 245, No. 2 Metrics Altmetric Score PDF download

Referência(s)
Altmetric
PlumX