Artigo Revisado por pares

Linearity and frequency response of pneumotachographs

1972; American Physiological Society; Volume: 32; Issue: 1 Linguagem: Inglês

10.1152/jappl.1972.32.1.121

ISSN

8750-7587

Autores

Kevin E. Finucane, B. A. Egan, Sierra Dawson,

Tópico(s)

Neonatal Respiratory Health Research

Resumo

ARTICLESLinearity and frequency response of pneumotachographsK. E. Finucane, B. A. Egan, and S. V. DawsonK. E. Finucane, B. A. Egan, and S. V. DawsonPublished Online:01 Jan 1972https://doi.org/10.1152/jappl.1972.32.1.121MoreSectionsPDF (2 MB)Download PDF ToolsExport citationAdd to favoritesGet permissionsTrack citations ShareShare onFacebookTwitterLinkedInWeChat Previous Back to Top Next Download PDF FiguresReferencesRelatedInformation Cited ByThe syringe potentiometer: a low-cost device for pneumotachograph calibrationTroy J. Cross, Eli F. Kelley, Tim A. Hardy, Jennifer M. J. Isautier, and Bruce D. Johnson14 October 2019 | Journal of Applied Physiology, Vol. 127, No. 4Venturi tube calibration for airflow and volume measurementFlow Measurement and Instrumentation, Vol. 60In vitro validation of computational fluid dynamic simulation in human proximal airways with hyperpolarized 3He magnetic resonance phase-contrast velocimetryLudovic de Rochefort, Laurence Vial, Redouane Fodil, Xavier Maître, Bruno Louis, Daniel Isabey, Georges Caillibotte, Marc Thiriet, Jacques Bittoun, Emmanuel Durand, and Gabriela Sbirlea-Apiou1 May 2007 | Journal of Applied Physiology, Vol. 102, No. 5Calibration of pneumotachographs using a calibrated syringeYongquan Tang, Martin J. Turner, Johnny S. Yem, and A. Barry Baker1 August 2003 | Journal of Applied Physiology, Vol. 95, No. 2Correction factors for oxygen and flow-rate effects on neonatal Fleisch and Lilly pneumotachometersPediatric Critical Care Medicine, Vol. 4, No. 2ATS/ACCP Statement on Cardiopulmonary Exercise TestingAmerican Journal of Respiratory and Critical Care Medicine, Vol. 167, No. 2Effect of nitric oxide, perfluorocarbon, and heliox on minute volume measurement and ventilator volumes deliveredCritical Care Medicine, Vol. 27, No. 8Design and calibration of unicapillary pneumotachographsA. Giannella-Neto, C. Bellido, R. B. Barbosa, and M. F. Vidal Melo1 January 1998 | Journal of Applied Physiology, Vol. 84, No. 1Identification of the mechanical non-linearities of the lungs during artificial ventilation in time domainMeasurement, Vol. 5, No. 2An interactive software for 81mKr pulmonary ventilation gatingComputers and Biomedical Research, Vol. 18, No. 5A computer-based data acquisition system for breathing and exercise entrainment studiesComputers in Biology and Medicine, Vol. 15, No. 5Pulmonary function testing in small laboratory mammals.Environmental Health Perspectives, Vol. 56Identification of transducer defect in respiratory impedence measurements by forced random noise. Correction of experimental dataRespiration Physiology, Vol. 40, No. 1Peak expiratory flow rate and rate of change of pleural pressureRespiration Physiology, Vol. 18, No. 2 More from this issue > Volume 32Issue 1January 1972Pages 121-126 Copyright & PermissionsCopyright © 1972 the American Physiological Societyhttps://doi.org/10.1152/jappl.1972.32.1.121PubMed5007001History Published online 1 January 1972 Published in print 1 January 1972 Metrics

Referência(s)