Size-specific Dose Estimation for CT: How Should It Be Used and What Does It Mean?
2012; Radiological Society of North America; Volume: 265; Issue: 3 Linguagem: Inglês
10.1148/radiol.12121919
ISSN1527-1315
AutoresJames A. Brink, Richard L. Morin,
Tópico(s)Radioactivity and Radon Measurements
ResumoHomeRadiologyVol. 265, No. 3 PreviousNext Reviews and CommentaryEditorialsSize-specific Dose Estimation for CT: How Should It Be Used and What Does It Mean?James A. Brink , Richard L. MorinJames A. Brink , Richard L. MorinAuthor AffiliationsFrom the Department of Diagnostic Radiology, Yale University School of Medicine, 789 Howard Ave, TE2-230, New Haven, CT 06519-1304 (J.A.B.); and Department of Diagnostic Radiology, Mayo Clinic, Jacksonville, Fla (R.L.M.).Address correspondence to J.A.B. (e-mail: [email protected]).James A. Brink Richard L. MorinPublished Online:Dec 1 2012https://doi.org/10.1148/radiol.12121919MoreSectionsFull textPDF ToolsAdd to favoritesCiteTrack CitationsPermissionsReprints ShareShare onFacebookXLinked In AbstractSize specific dose estimation on the basis of radiation exposure metrics such as volumetric CT dose index is a great step forward in our ability to monitor and control the radiation dose associated with CT imaging.References1 National Council on Radiation Protection and Measurements. Ionizing radiation exposure of the population of the United States. NCRP Report No. 160. Bethesda, Md: National Council on Radiation Protection and Measurements, 2009. Google Scholar2 American Association of Physicists in Medicine. Size-specific dose estimates (SSDE) in pediatric and adult body CT Examinations: report of AAPM Task Group 204. College Park, Md: American Association of Physicists in Medicine, 2011. Google Scholar3 International Commission on Radiation Units and Measurements. Patient dosimetry for x-rays used in medical imaging. Report 74. Bethesda, Md: International Commission on Radiation Units and Measurements, 2005; 89. Google Scholar4 Brady SL, Kaufman RA. Investigation of American Association of Physicists in Medicine Report 204 size-specific dose estimates for pediatric CT implementation. Radiology 2012;265(3):832–840. Link, Google Scholar5 Israel GM, Cicchiello L, Brink J, Huda W. Patient size and radiation exposure in thoracic, pelvic, and abdominal CT examinations performed with automatic exposure control. AJR Am J Roentgenol 2010;195(6):1342–1346. Crossref, Medline, Google Scholar6 Schindera ST, Nelson RC, Toth TL, et al.. Effect of patient size on radiation dose for abdominal MDCT with automatic tube current modulation: phantom study. AJR Am J Roentgenol 2008;190(2):W100–W105. Crossref, Medline, Google Scholar7 Christner JA, Braun NN, Jacobsen MC, Carter RE, Kofler JM, McCollough CH. Size-specific dose estimates for adult patients at CT of the torso. Radiology 2012;265(3):841–847. Link, Google ScholarArticle HistoryReceived August 26, 2012; revision requested August 28; revision received and final version accepted August 30.Published online: Dec 2012Published in print: Dec 2012 FiguresReferencesRelatedDetailsCited ByEstimation of size-specific dose estimate (SSDE) of CT scans using an effective diameter electron densityKhuloudAlmuqbil, AbdullahAbuhaimed, AhmedAbanomy, YazeedAlashban, AbdulrahmanAlhawas, Colin JMartin2024Mar1 | European Journal of Radiology, Vol. 172Automated size‐specific dose estimates framework in thoracic CT using convolutional neural network based on U‐Net modelSakultalaRuenjit, PunnaraiSiricharoen, KitiwatKhamwan31 January 2024 | Journal of Applied Clinical Medical Physics, Vol. 10Implantación de un protocolo de angio-TC coronaria basado en el índice de masa corporal: reducción de dosis, calidad de imagen y rendimiento diagnósticoH.Cuellar-Calabria, G.Burcet, M.S.Juarez-Garcia, J.L.Reyes-Juárez, M.N.Pizzi, S.Aguadé-Bruix, A.Roque2024Jan1 | Radiología, Vol. 66, No. 1Implementing a coronary CT angiography protocol based on the body mass index: Radiation dose reduction, image quality, and diagnostic performanceH.Cuellar-Calabria, G.Burcet, M.S.Juarez-Garcia, J.L.Reyes-Juárez, M.N.Pizzi, S.Aguadé-Bruix, A.Roque2024Jan1 | Radiología (English Edition), Vol. 66, No. 1ESTIMATION OF PEDIATRIC DOSE DESCRIPTORS ADAPTED TO INDIVIDUAL SPECIFIC SIZE FROM CT EXAMINATIONSMuhammad KabirAbdulkadir, Ibrahim LutfiShuaib, AnushaAchuthan, Radin ANasirudin, Ahmad Hadif ZaidinSamsudin, Noor DiyanaOsman27 July 2022 | Radiation Protection Dosimetry, Vol. 198, No. 17Automated Estimation of Patient’s Size Using Autowed Tool and Indosect Program: A Dosimetric Study for Paediatric Head CT ExaminationsMohammed KSaeed, Hassan AAlshamrani, AbdelmoneimSulieman, Youssef MAbdullah, MohamedYousef, Ali S A MAli, Khalaf AAlshamrani24 July 2022 | Radiation Protection Dosimetry, Vol. 346Is ultra low-dose CT with tin filtration useful for examination of SI joints? Can it replace X-ray in diagnostics of sacroiliitis?EvaKorcakova, JanaStepankova, DavidSuchy, PetrHosek, KristynaBajcurova, JanPernicky, HynekMirka2022Mar1 | Biomedical Papers, Vol. 166, No. 1Radiation dose levels of thoracic–lumbar spine CT in pediatric trauma patients and assessment of scan parameters for dose optimizationSevtapArslan, Mehmet RuhiOnur, YasinSarıkaya, H. NursunÖzcan, MithatHaliloğlu, DenizAkata14 October 2021 | Pediatric Radiology, Vol. 52, No. 1Direct measurement of radiation exposure dose to individual organs during diagnostic computed tomography examinationKazutaYamashita, KosakuHigashino, HiroakiHayashi, KazukiTakegami, FumioHayashi, YoshihiroTsuruo, KoichiSairyo8 March 2021 | Scientific Reports, Vol. 11, No. 1Effect of Contrast Agent Administration on Size-Specific Dose Estimates (SSDE) Calculations based on Water Equivalent Diameter in CT Head ExaminationsMoh. Shofi NurUtami, HeriSutanto, ChoirulAnam, Muharam BudiLaksono3 June 2021 | International Journal of Scientific Research in Science and TechnologyVan CTDI naar DLP naar EM.Hakkert28 February 2021Stralingsbelasting bij CT-onderzoekenG.Tempelman28 July 2021Normalized Dual-Energy Iodine Ratio Best Differentiates Renal Cell Carcinoma Subtypes Among Quantitative Imaging Biomarkers From Perfusion CT and Dual-Energy CTDineshManoharan, ArjunlokeshNetaji, KanikaDiwan, SanjaySharma2020Dec1 | American Journal of Roentgenology, Vol. 215, No. 6Image quality evaluation of dual-layer spectral CT in comparison to single-layer CT in a reduced-dose settingThuy DuongDo, StephanRheinheimer, Hans-UlrichKauczor, WolframStiller, TimWeber, StephanSkornitzke11 May 2020 | European Radiology, Vol. 30, No. 10AUTOMATIC BRAIN DOSE ESTIMATION IN COMPUTED TOMOGRAPHY USING PATIENT DICOM IMAGESSouhaGharbi, SalamLabidi, MokhtarMars10 February 2020 | Radiation Protection Dosimetry, Vol. 188, No. 4Clinical CT PhysicsDouglas E.Pfeiffer4 June 2020Dose reduction for CT coronary calcium scoring with a calcium-aware image reconstruction technique: a phantom studyRonaldBooij, Niels R.van der Werf, Ricardo P. J.Budde, DanielBos, Marcelvan Straten19 February 2020 | European Radiology, Vol. 30, No. 6Iodine Parameters in Triple-Bolus Dual-Energy CT Correlate With Perfusion CT Biomarkers of Angiogenesis in Renal Cell CarcinomaDineshManoharan, ArjunlokeshNetaji, Chandan J.Das, SanjaySharma2020Apr1 | American Journal of Roentgenology, Vol. 214, No. 4EFFECTS OF THE SCAN RANGE ON RADIATION DOSE IN THE COMPUTED TOMOGRAPHY COMPONENT OF ONCOLOGY POSITRON EMISSION TOMOGRAPHY/COMPUTED TOMOGRAPHYYusukeInoue, KazunoriNagahara, HirokoKudo, HiroyasuItoh1 December 2018 | Radiation Protection Dosimetry, Vol. 185, No. 1A real-time Monte Carlo tool for individualized dose estimations in clinical CTShobhitSharma, AnujKapadia, WanyiFu, EhsanAbadi, W PaulSegars, EhsanSamei4 November 2019 | Physics in Medicine & Biology, Vol. 64, No. 21Using radiation safely in cardiology: what imagers need to knowMichelle ClaireWilliams, ChristinaStewart, Nicholas WWeir, David ENewby18 February 2019 | Heart, Vol. 105, No. 10Tailoring CT Dose to Patient SizeYanKlosterkemper, ElisabethAppel, ChristophThomas, Oliver T.Bethge, JoelAissa, PatricKröpil, GeraldAntoch, JohannesBoos2018Dec1 | Academic Radiology, Vol. 25, No. 12Precise and Automatic Patient Positioning in Computed TomographyNataliaSaltybaeva, BernhardSchmidt, AndreasWimmer, ThomasFlohr, HatemAlkadhi2018Nov1 | Investigative Radiology, Vol. 53, No. 11Radiation exposure during CT-guided biopsies: recent CT machines provide markedly lower dosesNikaGuberina, MichaelForsting, AdrianRingelstein, SaravanabavaanSuntharalingam, KaiNassenstein, JensTheysohn, AxelWetter28 March 2018 | European Radiology, Vol. 28, No. 9Comparison of image quality and radiation dose between split-filter dual-energy images and single-energy images in single-source abdominal CTAndréEuler, Markus M.Obmann, ZsoltSzucs-Farkas, AchilleMileto, CarolineZaehringer, Anna L.Falkowski, David J.Winkel, DanieleMarin, BramStieltjes, BernhardKrauss, Sebastian T.Schindera19 February 2018 | European Radiology, Vol. 28, No. 8Relationship between size‐specific dose estimates and image quality in computed tomography depending on patient sizeHirokiKawashima, KatsuhiroIchikawa, ShinsukeHanaoka, KosukeMatsubara, TadanoriTakata4 May 2018 | Journal of Applied Clinical Medical Physics, Vol. 19, No. 4Reduction of patient radiation dose with a new organ based dose modulation technique for thoraco-abdominopelvic computed tomography (CT) (Liver dose right index)M.Fillon, S.Si-Mohamed, P.Coulon, A.Vuillod, P.Klahr, L.Boussel2018Jul1 | Diagnostic and Interventional Imaging, Vol. 99, No. 7-8Single-Acquisition Triple-Bolus Dual-Energy CT Protocol for Comprehensive Evaluation of Renal Masses: A Single-Center Randomized Noninferiority TrialDineshManoharan, SanjaySharma, Chandan J.Das, RajeevKumar, GeetikaSingh, PratikKumar2018Jul1 | American Journal of Roentgenology, Vol. 211, No. 1Size specific dose estimateAndrewMurphy, MattMorgan22 January 2018Pulmonary MRI morphometry modeling of airspace enlargement in chronic obstructive pulmonary disease and alpha‐1 antitrypsin deficiencyAlexeiOuriadov, EricLessard, KhadijaSheikh, GraceParraga, 15 February 2017 | Magnetic Resonance in Medicine, Vol. 79, No. 1Study on Different Method to Determine the Individual Diameter for Size-Specific Dose Estimates (SSDE) in Adult PatientsN. M.Huzail, M. A. A. M.Roslee, N. S. M.Azlan, N. D.Osman31 March 2018A comparison study of size-specific dose estimate calculation methodsRoshni A.Parikh, Michael A.Wien, Ronald D.Novak, David W.Jordan, PaulKlahr, StephanieSoriano, LeslieCiancibello, Sheila C.Berlin27 September 2017 | Pediatric Radiology, Vol. 48, No. 1The Medical Physicist’s Role in Radiation OptimizationEric L.Gingold2017Oct1 | Journal of the American College of Radiology, Vol. 14, No. 10Dose optimization in cardiac CTSandeepHedgire, BrianGhoshhajra, MannudeepKalra2017Sep1 | Physica Medica, Vol. 41Pediatric chest CT at chest radiograph doses: when is the ultralow-dose chest CT clinically appropriate?Javier E.Villanueva-Meyer, David M.Naeger, Jesse L.Courtier, Michael D.Hope, Jack W.Lambert, John D.MacKenzie, Andrew S.Phelps14 March 2017 | Emergency Radiology, Vol. 24, No. 4Clinical implementation of an emergency department coronary computed tomographic angiography protocol for triage of patients with suspected acute coronary syndrome, Brian B.Ghoshhajra, Richard A. P.Takx, Pedro V.Staziaki, HarshnaVadvala, PhillipKim, Tomas G.Neilan, Nandini M.Meyersohn, DanielBittner, Sumbal A.Janjua, ThomasMayrhofer, Jeffrey L.Greenwald, Quyhn A.Truong, SuhnyAbbara, David F. M.Brown, James L.Januzzi, SanjeevFrancis, John T.Nagurney, UdoHoffmann24 November 2016 | European Radiology, Vol. 27, No. 7THE SIZE-SPECIFIC DOSE ESTIMATE (SSDE) FOR TRUNCATED COMPUTED TOMOGRAPHY IMAGESChoirulAnam, FreddyHaryanto, RenaWidita, IdamArif, GeoffDougherty24 November 2016 | Radiation Protection Dosimetry, Vol. 175, No. 3Recent advances in cardiac computed tomography dose reduction strategies: a review of scientific evidence and technical developmentsSandeep S.Hedgire, VinitBaliyan, Brian B.Ghoshhajra, Mannudeep K.Kalra2017Jul1 | Journal of Medical Imaging, Vol. 4, No. 03Improved patient size estimates for accurate dose calculations in abdomen computed tomographyChang-LaeLee22 July 2017 | Journal of the Korean Physical Society, Vol. 71, No. 2The impact of patient table on size-specific dose estimate (SSDE)ChoirulAnam, FreddyHaryanto, RenaWidita, IdamArif, GeoffDougherty, DonaldMcLean10 November 2016 | Australasian Physical & Engineering Sciences in Medicine, Vol. 40, No. 1CT dose survey in adults: what sample size for what precision?StephenTaylor, AlainVan Muylem, NigelHowarth, Pierre AlainGevenois, DenisTack5 April 2016 | European Radiology, Vol. 27, No. 1Radiation dose in cardiac SPECT/CT: An estimation of SSDE and effective doseHamidAbdollahi, IsaacShiri, YazdanSalimi, MaghsoudSarebani, RezaMehdinia, Mohammad RezaDeevband, Seied RabiMahdavi, AhmadSohrabi, AhmadBitarafan-Rajabi2016Dec1 | European Journal of Radiology, Vol. 85, No. 12Strategies to Lessen the Radiation Risk from CT: A Multination PerspectiveMamdohAlObaidy, MiguelRamalho, Richard C.Semelka14 September 2016 | Current Radiology Reports, Vol. 4, No. 11Wide Variation in Radiation Exposure During Computerized TomographyAndrewCohen, KatieHughes, NatalieFahey, BrandonCaldwell, Chi HsiungWang, SangtaePark2016Sep1 | Urology, Vol. 95Application of 80-kVp tube voltage, low-concentration contrast agent and iterative reconstruction in coronary CT angiography: evaluation of image quality and radiation doseQiyongWu, YongWang, HuihuaKai, TaoWang, XiaoqiangTang, XiaoqinWang, ChangjiePan31 August 2016 | International Journal of Clinical Practice, Vol. 70, No. 9BQuality assurance in cardiovascular CT: a practical guideS.K.White, E.Castellano, N.Gartland, T.Patel, S.P.G.Padley, M.B.Rubens, E.D.Nicol2016Aug1 | Clinical Radiology, Vol. 71, No. 8Automated Calculation of Water‐equivalent Diameter (D W ) Based on AAPM Task Group 220ChoirulAnam, FreddyHaryanto, RenaWidita, IdamArif, GeoffDougherty8 July 2016 | Journal of Applied Clinical Medical Physics, Vol. 17, No. 4Pulmonary Imaging Biomarkers of Gas Trapping and Emphysema in COPD: 3He MR Imaging and CT Parametric Response MapsDante P. I. Capaldi, Nanxi Zha, Fumin Guo, Damien Pike, David G. McCormack, Miranda Kirby, Grace Parraga, 8 January 2016 | Radiology, Vol. 279, No. 2Comparison of Measured and Estimated CT Organ Doses for Modulated and Fixed Tube Current:AtulPadole, RanishDeedar Ali Khawaja, AlexiOtrakji, DaZhang, BobLiu, X. GeorgeXu, Mannudeep K.Kalra2016May1 | Academic Radiology, Vol. 23, No. 5A fully automated calculation of size-specific dose estimates (SSDE) in thoracic and head CT examinationsCAnam, FHaryanto, RWidita, IArif, GDougherty23 March 2016 | Journal of Physics: Conference Series, Vol. 694Does body mass index outperform body weight as a surrogate parameter in the calculation of size-specific dose estimates in adult body CT?JohannesBoos, Rotem SLanzman, PhilippHeusch, JoelAissa, ChristophSchleich, ChristophThomas, Lino MSawicki, GeraldAntoch, PatricKröpil2016Mar1 | The British Journal of Radiology, Vol. 89, No. 1059The Impact of Iterative Reconstruction on Computed Tomography Radiation Dosimetry: Evaluation in a Routine Clinical SettingRachael E.Moorin, David A. J.Gibson, Rene K.Forsyth, RichardFox, TejaGuda18 September 2015 | PLOS ONE, Vol. 10, No. 9Radiologic image formation: physical principles, technology, and radiation dose considerationsAndrewKarellas, SrinivasanVedantham2015Aug31Size-specific Dose Estimates for Chest, Abdominal, and Pelvic CT: Effect of Intrapatient Variability in Water-equivalent DiameterShuai Leng, Maria Shiung, Xinhui Duan, Lifeng Yu, Yi Zhang, Cynthia H. McCollough, 25 February 2015 | Radiology, Vol. 276, No. 1Size-Specific Dose Estimates for Evaluation of Individual Patient Dose in CT Protocol for Renal ColicŁukasz A.Waszczuk, MaciejGuziński, AnnaCzarnecka, Marek J.Sąsiadek2015Jul1 | American Journal of Roentgenology, Vol. 205, No. 1Image quality of low mA CT pulmonary angiography reconstructed with model based iterative reconstruction versus standard CT pulmonary angiography reconstructed with filtered back projection: an equivalency trialXavierMontet, Anne-LiseHachulla, AngelikiNeroladaki, FredericLador, ThierryRochat, DiomidisBotsikas, Christoph D.Becker21 December 2014 | European Radiology, Vol. 25, No. 6Radiation Dose Consideration in Kidney Stone CT Examinations: Integration of Iterative Reconstruction Algorithms With Routine Clinical PracticeYasirAndrabi, OlegPianykh, MuktaAgrawal, AvinashKambadakone, Michael A.Blake, Dushyant V.Sahani2015May1 | American Journal of Roentgenology, Vol. 204, No. 5Radiation dose reduction in thoracic and abdomen–pelvic CT using tube current modulation: a phantom studyAkmalSabarudin, ZakiraMustafa, Khadijah MohdNassir, Hamzaini AbdulHamid, ZhonghuaSun8 January 2014 | Journal of Applied Clinical Medical Physics, Vol. 16, No. 1Pediatric CT Dose Reduction for Suspected Appendicitis: A Practice Quality Improvement Project Using Artificial Gaussian Noise—Part 1, Computer SimulationsMichael J.Callahan, Patricia L.Kleinman, Keith J.Strauss, AndriyBandos, George A.Taylor, AndyTsai, Paul K.Kleinman2015Jan1 | American Journal of Roentgenology, Vol. 204, No. 1How I Do It: Managing Radiation Dose in CTWilliam W. Mayo-Smith, Amy K. Hara, Mahadevappa Mahesh, Dushyant V. Sahani, William Pavlicek, 24 November 2014 | Radiology, Vol. 273, No. 3Size mattersStephenBalter16 October 2014 | Catheterization and Cardiovascular Interventions, Vol. 84, No. 5Reduced Kilovoltage in Computed Tomography–Guided Intervention in a Community Hospital: Effect on the Radiation DoseSamanRezazadeh, Steven J.Co, SimonBicknell1 November 2014 | Canadian Association of Radiologists Journal, Vol. 65, No. 4Dose Reduction in Cardiothoracic CT: Review of Currently Available MethodsDiana E. Litmanovich, Denis M. Tack, Maryam Shahrzad, Alexander A. Bankier, 13 October 2014 | RadioGraphics, Vol. 34, No. 6In vitro dose measurements in a human cadaver with abdomen/pelvis CT scansDaZhang, AtulPadole, XinhuaLi, SarabjeetSingh, Ranish Deedar AliKhawaja, DiegoLira, TianyuLiu, Jim Q.Shi, AlexiOtrakji, Mannudeep K.Kalra, X. GeorgeXu, BobLiu26 August 2014 | Medical Physics, Vol. 41, No. 9Effect of Body Habitus on Radiation Dose during CT Fluoroscopy-Guided Spine InjectionsRonald J.Viola, Giao B.Nguyen, Terry T.Yoshizumi, Sandra S.Stinnett, Jenny K.Hoang, Peter G.Kranz1 January 2014 | Interventional Neuroradiology, Vol. 20, No. 5Coronary computed tomography angiography at 140 kV versus 120 kV: assessment of image quality and radiation exposure in overweight and moderately obese patientsAshley MLee, Leif-ChristopherEngel, Gladwin CHui, GaryLiew, MarosFerencik, Manavjot SSidhu, UdoHoffmann, Brian BGhoshhajra1 June 2014 | Acta Radiologica, Vol. 55, No. 5Demonstration of the Effect of Generic Anatomical Divisions versus Clinical Protocols on Computed Tomography Dose Estimates and Risk BurdenRachael E.Moorin, David A. J.Gibson, Rene K.Forsyth, RichardFox, GabrieleMulthoff30 May 2014 | PLoS ONE, Vol. 9, No. 5Radiation Dose Index of Renal Colic Protocol CT Studies in the United States: A Report from the American College of Radiology National Radiology Data RegistryAdam Lukasiewicz, Mythreyi Bhargavan-Chatfield, Laura Coombs, Monica Ghita, Jeffrey Weinreb, Gowthaman Gunabushanam, Christopher L. Moore, 27 January 2014 | Radiology, Vol. 271, No. 2Tuning of automatic exposure control strength in lumbar spine CTAD'Hondt, ACornil, PBohy, VDe Maertelaer, P AGevenois, DTack2014May1 | The British Journal of Radiology, Vol. 87, No. 1037Radiation Dose Reduction in Pediatric Cardiac Computed Tomography: Experience from a Tertiary Medical CenterBrian B.Ghoshhajra, Ashley M.Lee, Leif-ChristopherEngel, CsillaCeleng, Mannudeep K.Kalra, Thomas J.Brady, UdoHoffmann, Sjirk J.Westra, SuhnyAbbara20 July 2013 | Pediatric Cardiology, Vol. 35, No. 1Multidetector CT radiation dose optimisation in adults: short- and long-term effects of a clinical auditDenisTack, AndreasJahnen, SarahKohler, NicoHarpes, VivianeDe Maertelaer, CarloBack, Pierre AlainGevenois29 August 2013 | European Radiology, Vol. 24, No. 1Temporal Trends in Radiation Dose Associated with Coronary Computed Tomography AngiographyPaoloMarraccini, AlessandroMazzarisi, ClaraCarpeggiani, MathisSchluter, MarcoBrambilla, MassimilianoBianchi, LorenzoFaggioni, GiuseppeCoppini, CarloBartolozzi, EugenioPicano2014Jan1 | Open Journal of Radiology, Vol. 04, No. 01Low-dose CT in clinical diagnosticsJorge MFuentes-Orrego, Dushyant VSahani13 August 2013 | Expert Opinion on Medical Diagnostics, Vol. 7, No. 5CT Dose MetricsWalter Huda, , 1 June 2013 | Radiology, Vol. 267, No. 3Recommended Articles Radiation Dose Reduction at Pediatric CT: Use of Low Tube Voltage and Iterative ReconstructionRadioGraphics2018Volume: 38Issue: 5pp. 1421-1440Demystifying the CT Radiation Dose SheetRadioGraphics2022Volume: 42Issue: 4pp. 1239-1250Radiation Dose for Pediatric CT: Comparison of Pediatric versus Adult Imaging FacilitiesRadiology2019Volume: 291Issue: 1pp. 158-167Pediatric Chest CT Diagnostic Reference Ranges: Development and ApplicationRadiology2017Volume: 284Issue: 1pp. 219-227Dependence of Water-equivalent Diameter and Size-specific Dose Estimates on CT Tube PotentialRadiology2022Volume: 303Issue: 2pp. 404-411See More RSNA Education Exhibits Demystifying the CT Dose Sheet and Image HeadersDigital Posters2020Characteristics Of Deep Learning Reconstruction: Application In Clinical PracticeDigital Posters2021Optimizing Exposure Dose for CT: How to Decide the Imaging Condition Taking Advantage of Deep Learning-based ReconstructionDigital Posters2020 RSNA Case Collection Acute appendicitis with perforationRSNA Case Collection2020Cardiac fibromaRSNA Case Collection2020Takayasu ArteritisRSNA Case Collection2020 Vol. 265, No. 3 Supplemental MaterialMetrics Altmetric Score PDF download
Referência(s)