The recent operational performance of the CERN omega ring imaging cerenkov detector
1986; Institute of Electrical and Electronics Engineers; Volume: 33; Issue: 1 Linguagem: Inglês
10.1109/tns.1986.4337063
ISSN1558-1578
AutoresR. Apsimon, P. Flower, K Freeston, G. D. Hallewell, J. A. G. Morris, J.V. Morris, C. Paterson, P. Sharp, C.N. Uden, M. Davenport, J. Eades, P. Coyle, D. Mercer, S. Danaher, Richard McClatchey, N. A. Thacker, L.F. Thompson,
Tópico(s)Dark Matter and Cosmic Phenomena
ResumoWe discuss the design and construction of the Time Projection chambers (TPCs) of the Omega Ring Imaging Cerenkov Detector (RICH). Details are given of the TPC high voltage system and its monitoring and control. In addition, the operation and monitoring of the readout is described together with results of tests on the performance of the front end amplifiers. The operation of the RICH TPCs and electronics during the first data run of WA69, in 1984, is discussed together with relevant results from laboratory tests. Results from the preliminary analysis of a sample of data from the 1984 run are also presented.
Referência(s)