The Contradiction of Appropriate Shocks in Primary Prevention ICDs

2010; Lippincott Williams & Wilkins; Volume: 122; Issue: 25 Linguagem: Inglês

10.1161/circulationaha.110.000208

ISSN

1524-4539

Autores

Michael O. Sweeney,

Tópico(s)

Cardiac Arrhythmias and Treatments

Resumo

HomeCirculationVol. 122, No. 25The Contradiction of Appropriate Shocks in Primary Prevention ICDs Free AccessEditorialPDF/EPUBAboutView PDFView EPUBSections ToolsAdd to favoritesDownload citationsTrack citationsPermissions ShareShare onFacebookTwitterLinked InMendeleyReddit Jump toFree AccessEditorialPDF/EPUBThe Contradiction of Appropriate Shocks in Primary Prevention ICDsIncreasing and Decreasing the Risk of Death Michael O. Sweeney Michael O. SweeneyMichael O. Sweeney From the Brigham and Women's Hospital, Boston, MA. Originally published6 Dec 2010https://doi.org/10.1161/CIRCULATIONAHA.110.000208Circulation. 2010;122:2638–2641Other version(s) of this articleYou are viewing the most recent version of this article. Previous versions: January 1, 2010: Previous Version 1 Do I contradict myself? Very well, then I contradict myself, I am large, I contain multitudes.—Walt Whitman1It is a common fault of true believers to celebrate successful reinforcement of their belief system and to dismiss failures. Such has been the case with the evolution of implantable cardioverter-defibrillator (ICD) therapy. Evidence-based guidelines, national health care coverage determinations (CAG-00157R3, January 27, 2005), and clinical practice have been transformed by large randomized clinical trials demonstrating that ICDs reduce mortality in patients with reduced left ventricular ejection fraction (EF), regardless of etiology or accompanying symptoms of heart failure, and with no history of sustained ventricular tachyarrhythmia (VTA) or cardiac arrest.1a,2 This reduction in mortality is due entirely to prevention of sudden cardiac death (SCD) by VTA.3 Consequently, primary prevention ICDs have become an important healthcare industry, with heavily invested stakeholders (implanting physicians, medical device manufacturers, and hospitals) pursuing the same relentless mission: how can we get more ICDs into qualifying patients?Article see p 2645A few years ago, in an editorial arguing for national coverage determinations to align with evidence-based medicine, I wrote that in an earlier era intellectual opposition to the idea of the ICD was antivisionary.4,5 However, it now seems that contemporary application of primary prevention ICD therapy has become an anti-intellectual endeavor. Twenty years later, the translation to clinical practice has devolved to low EF, needs ICD. The problem with this declaration is that it is wrong on both points. At least 50% of SCD occurs in nonqualifying patients with normal or near-normal range EFs, and need is difficult to accept when absolute risk reduction is 1% to 3%1,2 and the morbidity consequences of ICD therapy are substantial. Nonetheless, primary prevention ICDs are here to stay and efforts to refine patient selection beyond low EF, needs ICD have not been helpful. Thus, the anti-intellectual status quo persists.Unexpected failure in clinical investigation provides the best opportunity for insight and learning. Proving what you know to be true is not nearly as illuminating as working out why you got it entirely wrong. The latter outcome composes another important purpose of clinical trial failures: to protect us from hubris.Two recent and notable clinical trial failures of primary prevention ICD therapy would seem to offer an opportunity for illumination. The highest risk period for SCD is immediately following acute myocardial infarction (MI). This risk declines exponentially after the first 6 to 12 months and then persists indefinitely for low-EF patients.6 Because clinically significant EF improvement is sometimes noted after medical therapy and revascularization accompanying acute MI, such patients were excluded from most primary prevention ICD trials. However, the high risk, early post-MI patient remained an irresistibly tempting and untreated target for ICD therapy to conquer. This population constituted the Defibrillator in Acute Myocardial Infarction Trial (DINAMIT),7 which randomized 653 patients with EF <35%, recent MI (6 to 40 days), and low heart rate variability or high resting heart rate to primary prevention ICD (311) or medical therapy (342). Randomization to ICD was associated with a 67% reduction in relative risk of sudden, presumed arrhythmic, death. Curiously, and unexpectedly, this reduction in SCD was completely offset by a parallel increase in nonarrhythmic death (70% relative risk compared to non-ICD arm), which was confined to the ICD minority subgroup that recorded electric therapies (mostly shocks) for VTA. Consequently, no survival difference was observed between treatment arms (hazard ratio: 1.08, 95% confidence interval: 0.76 to 1.55). For the first time in a large randomized clinical trial, a significant reduction in SCD did not transfer a reduction in mortality, and DINAMIT did not join the glitterati of primary prevention ICD trials MADIT-II1 and SCD-HeFT.2The response to the failure of DINAMIT was suspended disbelief. The true believers, who were also the strongest stakeholders, attributed the DINAMIT failure to an error of the second kind (β) and cited with personal conviction N of 1 experiences of ICD or life-vest saves in similar patients. Mostly, DINAMIT was ignored, except by the national coverage determination which, citing this failure, excluded early post-MI patients from primary prevention ICD coverage. Subsequently, and to the dismay of true believers, DINAMIT was reloaded in the Immediate Risk Stratification Improves Survival trial (IRIS)8 with the same result: an offsetting increase in nonsudden deaths cancelled out the presumed mortality benefit of electric therapy for VTA in the ICD arm. For IRIS, like DINAMIT, the denouement was a fizzle.The duplicative negative outcomes of DINAMIT and IRIS proved that in the case of ICDs early after MI, the failure to observe a mortality difference is because the truth is there isn't one. But what is the explanation for this contradiction? The explanation for the contradictory failure of DINAMIT and IRIS is unavoidably linked to the paradox that has recently emerged in secondary analyses of MADIT II, SCD-HEFT, and other ICD trials: an immediate and accelerating decline in survival after shocked VTA episodes.9–13 I believe this paradox is the premier thought problem facing ICD therapy and the pursuit of the answer provides the greatest opportunity for learning about the factors and conditions that limit its life-saving benefit.In this issue of Circulation, Dorian et al attempt to shine a light on the mortal contradiction of DINAMIT.14 Some of the abstracted elements of the current secondary analysis were presented during the 2004 Scientific Sessions of the American Heart Association, 11 months after publication of the primary manuscript. It is worth asking why it took 6 years for the current analysis to appear as a full manuscript. I suspect vindication by IRIS and emerging interest in the paradox of VTA shocks and increased mortality risk were enough for the authors to recognize new significance in a failed trial and to overcome whatever inertia previously limited the horizon of their enthusiasm for the topic.Characteristic of complex modeling analyses, translation of the numeric results to the meaning of the results is not straightforward. However, Dorian et al do provide enough raw materials to frame the thought experiment; the foundation can be summarized as follows: 1 A minority of ICD patients (59, 17.3%) had electrogram-adjudicated (appropriate) VTA therapies; 2/3 of these events occurred within the first year. 2 These patients appeared to be sicker at enrollment (more heart failure, prior MI, less β-blocker use) and had nearly double the intercurrent event rates (acute coronary syndrome, heart failure) during follow up compared to other subgroups. 3 Mortality was higher in these patients (36%) compared to ICD patients without VTA therapies (13%) or the control group (16%); VTA therapies (70% shocks) transferred a ≥5 times increased risk of death. 4 Among these ICD patients with VTA therapies, mortality was highest (50%) for those with intercurrent events versus those without such events (18.5%). 5 The majority of deaths (61% to 67%) in the ICD group (with/without VTA therapies) were cardiac nonarrhythmic; conversely, the majority (54%) of deaths in the control group were sudden and presumed arrhythmic.The 5-fold increased relative risk of death after VTA therapies (mostly shocks) in DINAMIT replicates the 3.4-fold increased risk of death after VTA shocks in MADIT II9 and 5.7-fold increased risk after VTA shocks in SCD-HeFT.12 This consistently reproducing relationship between shocked VTA episodes and mortality risk can be summarized as follows: patients with VTA and shocks have higher mortality than otherwise similar patients with neither, and patients with more VTA and more shocks have higher mortality than patients with less of both.The authors' interpretation of this line of evidence is congruent with the most often held view of the link between shocked VTA episodes and increased mortality risk in other primary prevention ICD randomized clinical trials: patients with VTA and shocks are at higher risk for dying, and the former is a marker for, but mechanistically unrelated to, the latter. In simpler terms, the lack of a mortality benefit in the ICD group despite VTA electric therapies is not a device failure, but a patient failure. This is the safe fall-back position of the true believer. When annualized survival rates are constituted, no credit is given for a life saved by VTA electric therapy at 6 months, nor is fault assigned for the subsequent death at 11 months.This default argument persists because it is the easiest to make and always within reach. DINAMIT is no exception and the most obvious problem is that the enrollment criteria guaranteed a study population enriched with a huge burden of uncorrected peri-MI coronary disease superimposed on low EF. The qualifying (index) MI was preceded by chronic MI in 30% to 50% of patients; only 2/3 had any form of acute reperfusion, and those who were candidates for complete coronary revascularization (percutaneous or surgical) were intentionally excluded. If the goal was enrollment of a supremely high risk population, the strategy was a success, but it may have unintentionally doomed the possibility of an ICD mortality benefit due to severely competing threats to survival. This is an old argument of logic that remains relevant.15While lack of adequate revascularization may actively counterbalance ICD mortality benefit in a negative direction, robust revascularization may passively neutralize mortality benefit by suppressing cardiac arrest. This lesson is provided by the Coronary Artery Bypass Graft (CABG) Patch Trial,16 another almost forgotten, failed primary prevention ICD randomized clinical trial, which is the Gemini twin, Pollux to Castor, of DINAMIT. Among 900 patients with severe ischemic cardiomyopathy (EF <36) randomized to ICD or no antiarrhythmic therapy at the time of bypass surgery, no mortality difference was recorded. Though ICDs reduced arrhythmic death by 54%, annualized arrhythmic mortality was very low overall (6.9% control, 4.0% ICD). Yet, programmed ventricular stimulation induced sustained VTA in 43% of patients,17 similar to MADIT-I, in which prophylactic ICDs delivered a huge mortality benefit.18 This suggests that the CABG-Patch population, which was demographically similar to MADIT-I, also had sufficient substrate for spontaneous VTA, but that complete coronary revascularization "unlinked" arrhythmic substrate from mortality outcome (SCD),17 probably by preventing lethal ventricular fibrillation (VF), even if risk for less lethal ventricular tachycardia (Vt) due to stable reentry persisted. This hypothesis is consistent with the observation that coronary artery bypass grafting suppresses inducible VF, but not stable Vt, in cardiac arrest survivors.19 Coronary artery bypass grafting reduces the risk of sudden death in low EF20,21 and weakens the mortality benefit of primary prevention ICDs for up to 2 years following revascularization.22,23There are, however, nagging inconsistencies that nurture more subtle and troubling possibilities. The timing of intercurrent (mostly ischemic) events appeared to be randomly related to the timing of VTA electric therapies: 56% occurred after therapy, 34% prior, and 10% on the same day. Yet survival time after VTA electric therapies was similarly poor (<1 day-<1 year), regardless of the timing of intercurrent events. The authors failed to examine the distribution of intercurrent events and SCD in the control group. This was a missed opportunity to dissociate and isolate any independent effects of intercurrent events and VTA electric therapies on mortality.The problem with the thesis that the lack of a mortality benefit from shocked VTA is strictly a patient failure is that it excludes the possibility for understanding alternative and more disruptive explanations which might lead to improved patient survival. The argument becomes a little involved here. The increasing risk relationship between VTA shocks and mortality could be explained by the adverse effects of VTA in failing hearts, cardiac electric trauma associated with shocks, or both, because almost all episodes in these studies were shocked. VTA shocks saved enough lives in MADIT-II and SCD-HeFT to achieve a mortality advantage compared to medical therapy, and the increased mortality risk of shocked VTA episodes did not completely counterbalance the mortality benefit of VTA termination. Yet in DINAMIT, and presumably in IRIS, the mortality benefit of VTA termination (mostly shocks) was completely offset by an immediate and dramatic increased risk of death after electric therapy.The relationship between shocked VTA episodes and death must be complex. This complexity invokes the benefit versus harm paradox of high voltage shocks. Large electric currents destroy cardiac myocytes.24 Sufficiently strong shocks terminate VF but cause temporary or permanent damage to the heart, whereas weaker shocks cause less damage but do not defibrillate.25 Extensive literature over the past 35 years describes adverse cellular, tissue, and cardiac mechanical responses to large electric currents during defibrillation shocks in animals and humans.26–29 These effects are directly related to increasing shock energy and VTA duration and are enhanced by recent or ongoing ischemia.30,31 This latter finding has critically important interpretive implications for DINAMIT and IRIS.In DINAMIT, the risk of death increased as a dramatic step function immediately after VTA electric therapy (mostly shocks). Survival time after electric therapy for VF (all shocks) was substantially less compared to electric therapy for Vt (mostly shocks). There were too few treated VTA events, insufficiently differentiated by electric therapy type, to isolate the effect of VTA type and therapy type on mortality. A recent analysis of 2135 ICD patients from 4 trials that broadly incorporated anti tachycardia pacing (ATP) for Vt (<190 bpm) and fast Vt (190 to 250 bpm) provided a unique opportunity to uncouple VTA type from electric therapy type with respect to mortality risk.13 Sustained VTA (sufficient to satisfy ICD detection), adjusted for other mortality predictors but unqualified for electric therapy type delivered (shocks versus ATP), was independently associated with increased mortality risk, and this risk was ≈10-times greater for VF versus Vt, implying that rhythm severity influences mortality. Cumulative shocked VTA episodes of all types increased the risk of death by 20%, whereas ATP-terminated Vt and fast Vt episodes did not increase mortality risk. Inappropriate shocks were associated with increased mortality risk in MADIT-II and SCD-HeFT, but the magnitude of effect was substantially less than appropriate shocks.11,12 Shock-free ATP termination, though sparingly applied, did not transfer increased mortality risk in MADIT-II.11 ICD shocks during implant testing and transthoracic shocks for induced VTA result in high intensity cardiac specific biomarker release, whereas ATP for induced VTA and cardioversion shocks for AF do not.32 Collectively, these observations suggest an interaction between conditioning rhythm type (supraventricular versus ventricular) and adverse effects of high voltage shocks. Furthermore, there may be differences between VTA subtypes (Vt, fast Vt, VF) and shock effects, where greater consequences are observed for VF shocks, and patients with more VTA may be more susceptible to harm from shocks.The distribution of VTA type + electric therapy type in DINAMIT is therefore important. There were 81 treated VTA events in 59 patients who were electrogram-classified as Vt (50, 61.7%) or VF (31, 38.2%). Qualified by VTA type + electric therapy type, 18 patients (30.5%) received ATP-only, 15 (25.4%) received ATP + shocks, and 26 (44.1%) received only shocks. This is a substantially higher frequency distribution of VF and shocks compared to other contemporary ICD trials that excluded early post-MI patients, where VF accounts for <5% to 10% of VTA and ATP terminates up ≥80% of all remaining VTA (Vt and FVT).13,33 This is important because though VF must be treated with shocks it may also be the worst conditioning rhythm for shock harm.The explanation for the contradiction of increased and reduced risk of death after VTA shocks is undetermined. Understanding whether high voltage shocks delivered into the failing heart preconditioned by VTA have an adverse effect on mortality is the most important question facing ICD therapy delivery and development. To dismiss the link between shocked VTA and death as an inevitable consequence of a patient doomed to die is to dismiss the possibility of improving survival. Even proponents of the shock-only subcutaneous ICD concept,34 facing an increasingly challenged argument that shocks are inconsequential amid a groundswell of concern that they are and that we should be doing something about it, wisely hedged their position with intellectual property for future application of subcutaneously-delivered ATP.35 Ongoing clinical trials to suppress shocks and improve mortality using drugs, VTA substrate modification, and device-based strategies should provide enlightenment.DisclosuresNone.FootnotesThe opinions expressed in this article are not necessarily those of the editors or of the American Heart Association.Correspondence to Michael O. Sweeney, MD, Cardiac Arrhythmia Service, Brigham and Women's Hospital, Shapiro Cardiovascular Center, 70 Francis Street, Boston, MA 02115. E-mail mosweeney@partners.orgReferences1. Whitman W. Song of Myself. Leaves of Grass. New York, NY: Fowler & Wells; 1855.Google Scholar1a. Moss AJ, Zareba W, Hall WJ, Klein H, Wilber DJ, Cannom DS, Daubert JP, Higgins SL, Brown MW, Andrews MLMulticenter Automatic Defibrillator Implantation Trial II Investigators. Prophylactic implantation of a defibrillator in patients with myocardial infarction and reduced ejection fraction. N Engl J Med. 2002; 346:877–883.CrossrefMedlineGoogle Scholar2. Bardy GH, Lee KL, Mark DB, Poole JE, Packer DL, Boineau R, Domanski M, Troutman C, Anderson J, Johnson G, McNulty SE, Clapp-Channing N, Davidson-Ray LD, Fraulo ES, Fishbein DP, Luceri RM, Ip JHSudden Cardiac Death in Heart Failure Trial (SCD-HeFT) Investigators. Amiodarone or an implantable cardioverter-defibrillator for congestive heart failure. N Engl J Med. 2005; 352:225–237.CrossrefMedlineGoogle Scholar3. Packer DL, Prutkin JM, Hellkamp AS, Mitchell LB, Bernstein RC, Wood F, Boehmer JP, Carlson MD, Frantz RP, McNulty SE, Rogers JG, Anderson J, Johnson GW, Walsh MN, Poole JE, Mark DB, Lee KL, Bardy GH. Impact of implantable cardioverter-defibrillator, amiodarone, and placebo on the mode of death in stable patients with heart failure: analysis from the sudden cardiac death in heart failure trial. Circulation. 2009; 120:2170–2176.LinkGoogle Scholar4. Lown B, Axelrod P. Implanted standby defibrillators. Circulation. 1972; 46:637–639.LinkGoogle Scholar5. Sweeney MO, Schoenfeld MH, Cannom DS. Rules of evidence: CMS and primary prevention of sudden cardiac death in systolic heart failure. Pacing Clin Electrophysiol. 2005; 28:81–88.CrossrefMedlineGoogle Scholar6. Solomon SD, Zelenkofske S, McMurray JJV, Finn PV, Velazquez E, Ertl G, Harsanyi A, Rouleau JL, Maggioni A, Kober L, White H, Van de Werf F, Pieper K, Califf RM, Pfeffer MAValsartan in Acute Myocardial Infarction Trial (VALIANT) Investigators. Sudden death in patients with myocardial infarction and left ventricular dysfunction, heart failure, or both. N Engl J Med. 2005; 352:2581–2588.CrossrefMedlineGoogle Scholar7. Hohnloser SH, Kuck KH, Dorian P, Roberts RS, Hampton JR, Hatala R, Fain E, Gent M, Connolly SJDINAMIT Investigators. Prophylactic use of an implantable cardioverter-defibrillator after acute myocardial infarction. N Engl J Med. 2004; 351:2481–2488.CrossrefMedlineGoogle Scholar8. Steinbeck G, Andresen D, Seidl K, Brachmann J, Hoffmann E, Wojciechowski D, Kornacewicz-Jach Z, Sredniawa B, Lupkovics G, Hofgärtner F, Lubinski A, Rosenqvist M, Habets A, Wegscheider K, Senges JIRIS Investigators. Defibrillator implantation early after myocardial infarction. N Engl J Med. 2009; 361:1427–1436.CrossrefMedlineGoogle Scholar9. Moss AJ, Greenberg H, Case RB, Zareba W, Hall WJ, Brown MW, Daubert JP, McNitt S, Andrews ML, Elkin ADMulticenter Automatic Defibrillator Implantation Trial-II (MADIT-II) Research Group. Long-term clinical course of patients after termination of ventricular tachyarrhythmia by an implanted defibrillator. Circulation. 2004; 110:3760–3765.LinkGoogle Scholar10. Goldenberg I, Moss AJ, Hall WJ, McNitt S, Zareba W, Andrews ML, Cannom DSMulticenter Automatic Defibrillator Implantation Trial (MADIT) II Investigators. Causes and consequences of heart failure after prophylactic implantation of a defibrillator in the Multicenter Automatic Defibrillator Implantation Trial II. Circulation. 2006; 113:2810–2817.LinkGoogle Scholar11. Daubert JP, Zareba W, Cannom DS, McNitt S, Rosero SZ, Wang P, Schuger C, Steinberg JS, Higgins SL, Wilber DJ, Klein H, Andrews ML, Hall WJ, Moss AJMADIT II Investigators. Inappropriate implantable cardioverter-defibrillator shocks in MADIT II: frequency, mechanisms, predictors, and survival impact. J Am Coll Cardiol. 2008; 51:1357–1365.CrossrefMedlineGoogle Scholar12. Poole JE, Johnson GW, Hellkamp AS, Anderson J, Callans DJ, Raitt MH, Reddy RK, Marchlinski FE, Yee R, Guarnieri T, Talajic M, Wilber DJ, Fishbein DP, Packer DL, Mark DB, Lee KL, Bardy GH. Prognostic importance of defibrillator shocks in patients with heart failure. N Engl J Med. 2008; 359:1009–1017.CrossrefMedlineGoogle Scholar13. Sweeney MO, Sherfesee L, DeGroot P, Wathen M, Wilkoff BL. Differences in effects of electrical therapy type for ventricular arrhythmias on mortality in implantable cardioverter-defibrillator patients. Heart Rhythm. 2010; 7:353–360.CrossrefMedlineGoogle Scholar14. Dorian P, Hohnloser SH, Thorpe KE, Roberts RS, Kuck K-H, Gent M, Connolly SJ. Mechanisms underlying the lack of effect of implantable cardioverter-defibrillator therapy on mortality in high-risk patients with recent myocardial infarction: insights from the Defibrillation in Acute Myocardial Infarction Trial (DINAMIT). Circulation. 2010; 122:2645–2652.LinkGoogle Scholar15. Sweeney MO, Ruskin JN, Garan H, McGovern BA, Guy ML, Torchiana DF, Vlahakes GJ, Newell JB, Semigran MJ, Dec GW. Influence of the implantable cardioverter/defibrillator on sudden death and total mortality in patients evaluated for cardiac transplantation. Circulation. 1995; 92:3273–3281.LinkGoogle Scholar16. Bigger JTCoronary Artery Bypass Graft (CABG) Patch Trial Investigators. Prophylactic use of implanted cardiac defibrillators in patients at high risk for ventricular arrhythmias after coronary artery bypass graft surgery. N Engl J Med. 1997; 337:1569–1575.CrossrefMedlineGoogle Scholar1. Bigger JT, Rottman JN, Whang W, Steinman RC, DiMarco JP, Cook JR, Estes NAM, Herre JMfor the CABG-Patch Investigators. CABG surgery unlinked the arrhythmic substrate from arrhythmia outcomes in the CABG-Patch Trial. Circulation. 1999; 100 (suppl I):I–367.Google Scholar18. Moss AJ, Hall WJ, Cannom DS, Daubert JP, Higgins SL, Klein H, Levine JH, Saksena S, Waldo AL, Wilber D, Brown MW, Moonseong HMulticenter Automatic Defibrillator Implantation Trial Investigators. Improved survival with an implanted defibrillator in patients with coronary disease at high risk for ventricular arrhythmia. N Engl J Med. 1996; 335:1993–1940.CrossrefGoogle Scholar19. Kelly P, Ruskin JN, Vlahakes GJ, Buckley MJ, Freeman CS, Garan H. Surgical coronary revascularization in survivors of prehospital cardiac arrest: its effect on inducible ventricular arrhythmias and long-term survival. J Am Coll Cardiol. 1990; 15:267–273.CrossrefMedlineGoogle Scholar20. Passamani E, Davis KB, Gillespie MJ, Killip T. A randomized trial of coronary artery bypass surgery. Survival of patients with a low ejection fraction. N Engl J Med. 1985; 312:1665–1671.CrossrefMedlineGoogle Scholar21. Barsheshet A, Goldenberg I, Narins CR, Moss AJ, McNitt S, Wang PJ, Huang DT, Hall WK, Zareba W, Eldar M, Guetta V. Time dependence of life-threatening ventricular tachyarrhythmias after coronary revascularization in MADIT-CRT. Heart Rhythm. 2010; 7:1421–1427.CrossrefMedlineGoogle Scholar22. Al-Khatib SM, Hellkamp AS, Lee KL, Anderson J, Poole JE, Mark DB, Bardy GHSCD-HeFT Investigators. Implantable cardioverter defibrillator therapy in patients with coronary revascularization in the Sudden Cardiac Death in Heart Failure Trial (SCD-HeFT). J Cardiovasc Electrophysiol. 2008; 19:1059–1065.CrossrefMedlineGoogle Scholar23. Goldenberg I, Moss AJ, McNitt S, Zareba W, Hall WJ, Andrews ML, Wilber DJ, Klein HUMADIT-II Investigators. Time dependence of defibrillator benefit after coronary revascularization in the Multicenter Automatic Defibrillator Implantation Trial (MADIT)-II. J Am Coll Cardiol. 2006; 47:1811–1817.CrossrefMedlineGoogle Scholar24. Nikolski VP, Efimov IR. Electroporation of the heart. Europace. 2005; 7:S146–S154.CrossrefMedlineGoogle Scholar25. Walcott GP, Killingsworth CR, Ideker RE. Do clinically relevant transthoracic defibrillation energies cause myocardial damage and dysfunction?Resuscitation. 2003; 59:59–70.CrossrefMedlineGoogle Scholar26. Xie J, Weil MH, Sun S, Tang W, Sato Y, Jin X, Bisera J. High-energy defibrillation increases the severity of postresuscitation myocardial dysfunction. Circulation. 1997; 96:683–688.LinkGoogle Scholar27. Dahl CF, Ewy GA, Warner ED, Thomas ED. Myocardial necrosis from direct current countershock. Effect of paddle-electrode size and time interval between discharges. Circulation. 1974; 50:956–961.LinkGoogle Scholar28. Barker-Voelz MA, Van Vleet JF, Tacker WA, Bourland JD, Geddes LA, Schollmeyer MP. Alterations induced by a single defibrillating shock applied through a chronically implanted catheter electrode. J Electrocardiol. 1983; 16:167–169.CrossrefMedlineGoogle Scholar29. Epstein AE, Kay GN, Plumb VJ, Dailey SM, Anderson PG. Gross and macroscopic pathological changes associated with nonthoracotomy implantable defibrillator leads. Circulation. 1998; 98:1517–1524.LinkGoogle Scholar30. Geuze RH, de Vente J. Arrhythmias and left ventricular function after defibrillation during acute myocardial function in the intact dog. Am Heart J. 1983; 106(2):292–299.CrossrefMedlineGoogle Scholar31. Hurst TM, Hinrichs M, Breidenbach C, Katz N, Waldecker B. Detection of myocardial injury during transvenous implantation of automatic cardioverter-defibrillators. J Am Coll Cardiol. 1999; 34:402–408.CrossrefMedlineGoogle Scholar32. Runsiö M, Kallner A, Källner G, Rosenqvist M, Bergfeldt L. Myocardial injury after electrical therapy for cardiac arrhythmias assessed by troponin-T release. Am J Cardiol. 1997; 79:1241–1245.CrossrefMedlineGoogle Scholar33. Sweeney MO, Ellenbogen KA, Tang ASL, Whellan D, Mortensen P, Giraldi F, Sandler DA, Sherfesee L, Sheldon TManaged Ventricular Pacing Versus VVI 40 Pacing Trial Investigators. Atrial pacing or ventricular backup-only pacing in implantable cardioverter-defibrillator patients[Epub ahead of print]. Heart Rhythm2010.CrossrefGoogle Scholar34. Bardy GH, Smith WM, Hood MA, Crozier IG, Melton IC, Jordaens L, Theuns D, Park RE, Wright DJ, Connelly DT, Fynn SP, Murgatroyd FD, Sperzel J, Neuzner , Spitzer SG, Ardashev AV, Oduro A, Boersma L, Maass AH, Van Gelder IC, Wilde AA, van Dessel PF, Knops RE, Barr CS, Lupo P, Cappato R, Grace AA. An entirely subcutaneous implantable cardioverter-defibrillator. N Engl J Med. 2010; 363:36–44.CrossrefMedlineGoogle Scholar35. Bardy GH, Cappato R, Rissmann WJinventors; Cameron Health Inc., assignee. Monophasic waveform for anti-tachycardia pacing for a subcutaneous implantable cardioverter-defibrillator. Application Number 10/984,585, continuation of US patent 6,647,292. September 18, 2000.Google Scholar eLetters(0)eLetters should relate to an article recently published in the journal and are not a forum for providing unpublished data. Comments are reviewed for appropriate use of tone and language. Comments are not peer-reviewed. Acceptable comments are posted to the journal website only. Comments are not published in an issue and are not indexed in PubMed. Comments should be no longer than 500 words and will only be posted online. References are limited to 10. Authors of the article cited in the comment will be invited to reply, as appropriate.Comments and feedback on AHA/ASA Scientific Statements and Guidelines should be directed to the AHA/ASA Manuscript Oversight Committee via its Correspondence page.Sign In to Submit a Response to This Article Previous Back to top Next FiguresReferencesRelatedDetailsCited By Katritsis D and Morady F (2022) Ventricular a

Referência(s)
Altmetric
PlumX