Results from a new die-to-database reticle inspection platform

2007; SPIE; Volume: 6518; Linguagem: Inglês

10.1117/12.712367

ISSN

1996-756X

Autores

W. H. Broadbent, Yalin Xiong, Michael Giusti, R. W. Walsh, Aditya Dayal,

Tópico(s)

Electron and X-Ray Spectroscopy Techniques

Resumo

A new die-to-database high-resolution reticle defect inspection system has been developed for the 45nm logic node and extendable to the 32nm node (also the comparable memory nodes). These nodes will use predominantly 193nm immersion lithography although EUV may also be used. According to recent surveys, the predominant reticle types for the 45nm node are 6% simple tri-tone and COG. Other advanced reticle types may also be used for these nodes including: dark field alternating, Mask Enhancer, complex tri-tone, high transmission, CPL, EUV, etc. Finally, aggressive model based OPC will typically be used which will include many small structures such as jogs, serifs, and SRAF (sub-resolution assist features) with accompanying very small gaps between adjacent structures. The current generation of inspection systems is inadequate to meet these requirements. The architecture and performance of a new die-to-database inspection system is described. This new system is designed to inspect the aforementioned reticle types in die-to-database and die-to-die modes. Recent results from internal testing of the prototype systems are shown. The results include standard programmed defect test reticles and advanced 45nm and 32nm node reticles from industry sources. The results show high sensitivity and low false detections being achieved.