Artigo Acesso aberto Revisado por pares

Accuracy of 16-channel multi-detector row chest computed tomography with thin sections in the detection of metastatic pulmonary nodules☆☆☆

2008; Oxford University Press; Volume: 33; Issue: 3 Linguagem: Inglês

10.1016/j.ejcts.2007.12.011

ISSN

1873-734X

Autores

Moon Chul Kang, Chang Hyun Kang, Hyun Ju Lee, Jin Mo Goo, Young Tae Kim, Joo Hyun Kim,

Tópico(s)

Advanced X-ray and CT Imaging

Resumo

Objectives: The inaccuracy of conventional CT makes open thoracotomy and manual palpation inevitable in pulmonary metastasectomy. However, the introduction of multi-detector row CT technology made it possible to detect pulmonary nodules with a diameter of 1 mm. The purpose of this study was to investigate the accuracy of 1 mm thin-section 16-channel multi-detector row CT (TSMDCT) in the detection of metastatic pulmonary nodules. Methods: Twenty-seven patients who underwent pulmonary metastasectomy between November 2005 and September 2006 were included in the study. The primary tumors were colorectal cancer (n = 11), renal cell carcinoma (n = 5), osteosarcoma (n = 3), hepatocellular carcinoma (n = 3), thymic tumor (n = 2), bladder cancer (n = 1), thyroid cancer (n = 1), and primitive neuroectodermal tumor (n = 1). TSMDCT was performed in all patients in order to evaluate the location and number of metastatic nodules. The patients were divided into osteosarcoma and non-osteosarcoma groups, and the accuracy of TSMDCT was evaluated by comparison with the pathologic diagnosis of metastatic nodules. Results: A total of 117 nodules were detected preoperatively by TSMDCT scanning, and 198 nodules were resected during the operation. A total of 101 nodules were pathologically confirmed to be metastatic nodules. In the osteosarcoma group, the sensitivity, specificity, positive predictive value, and negative predictive value were 34%, 93%, 92%, and 38%, respectively. In the non-osteosarcoma group, the sensitivity, specificity, positive predictive value, and negative predictive value were 97%, 54%, 64%, and 96%, respectively. Subgroup analysis in the non-osteosarcoma group revealed that nodule size over 5 mm, number of metastatic nodules less than five, and disease-free interval over 24 months showed 100% sensitivity by preoperative TSMDCT. Conclusions: TSMDCT with 1 mm thickness image reconstruction showed high detection rate of metastatic pulmonary nodules in the patients with non-osteosarcoma. In highly selected subgroups, TSMDCT detected all the metastatic nodules which manual palpation could detect. Further study on the application of TSMDCT in thoracoscopic metastasectomy should be performed.

Referência(s)