Artigo Revisado por pares

Treatment of Renal Artery Aneurysm With the Multilayer Stent

2008; SAGE Publishing; Volume: 15; Issue: 2 Linguagem: Inglês

10.1583/07-2222.1

ISSN

1545-1550

Autores

Michel Henry, Antonios Polydorou, Noureddine Frid, Patricia Gruffaz, Alain Cavet, Isabelle Henry, Michèle Hugel, Daniel A. Rüfenacht, Luca Augsburger, Matthieu De Beule, Pascal Verdonck, Maurice Bonneau, Chantal Kang, Rafik Ouared, Bastien Chopard,

Tópico(s)

Aortic aneurysm repair treatments

Resumo

Purpose:To describe a new type of stent consisting of a 3-dimensional (3D) braided tube made of 2 interconnected layers without any covering to treat a renal artery aneurysm. Case Report:A 78-year-old hypertensive man with multiple comorbidities was incidentally found to have a large (28-×30 mm) saccular aneurysm in the main right renal artery involving the inferior renal artery. Via a percutaneous femoral approach, a 6–3×0-mm Multilayer stent was deployed easily in front of the aneurysm neck covering the inferior renal artery. Blood flow inside the sac was immediately and significantly reduced. All the renal artery branches remained patent. Blood pressure returned to normal after the procedure. At 6 months, angiography showed complete shrinkage of the aneurysm wall; all the inferior renal artery branches remained patent. Conclusion:The 3D multilayer fluid modulating stent concept appears to be a viable alternative for renal aneurysm exclusion. A larger study is underway to evaluate this new stent in other peripheral aneurysms.

Referência(s)