Blood Loss Associated with Ring Uncemented Total Knee Replacement: Comparison between Continuous and Intermittent Suction Drainage
1984; SAGE Publishing; Volume: 77; Issue: 7 Linguagem: Inglês
10.1177/014107688407700706
ISSN1758-1095
Autores Tópico(s)Orthopaedic implants and arthroplasty
ResumoIn a retrospective comparison of blood loss following uncemented total knee replacement, in which either continuous or intermittent suction drainage was used, measured blood loss was significantly greater with continuous drainage. However, a method of calculating actual blood loss demonstrated no significant difference. With intermittent drainage, more blood remains undetected around the knee joint; this technique should therefore be abandoned in favour of continuous suction drainage.