The integrated intensity of every reflection in the (hhl) zone of calcium fluoride, within a radius of sin 0/2 = 1.00/~-1, has been measured diffractometrically in seven different laboratories.All participants in this project used the same ground sphere of calcium fluoride.A fixed effects analysis-of-variance model was used to investigate the seven scaled sets of structure amplitudes.Most sets contained IFI z values within five per cent of the probable true values.It is unlikely that any experiment measured IFI 2 values to better than two per cent.The largest systematic errors are scattering angle dependent.