Carta Acesso aberto Revisado por pares

Central Aortic Blood Pressure and Cardiovascular Risk

2008; Lippincott Williams & Wilkins; Volume: 51; Issue: 6 Linguagem: Inglês

10.1161/hypertensionaha.107.108910

ISSN

1524-4563

Autores

Alberto Avolio,

Tópico(s)

Heart Rate Variability and Autonomic Control

Resumo

HomeHypertensionVol. 51, No. 6Central Aortic Blood Pressure and Cardiovascular Risk Free AccessEditorialPDF/EPUBAboutView PDFView EPUBSections ToolsAdd to favoritesDownload citationsTrack citationsPermissions ShareShare onFacebookTwitterLinked InMendeleyReddit Jump toFree AccessEditorialPDF/EPUBCentral Aortic Blood Pressure and Cardiovascular RiskA Paradigm Shift? Alberto Avolio Alberto AvolioAlberto Avolio From the Australian School of Advanced Medicine, Macquarie University, Sydney, New South Wales 2109, Australia. Originally published21 Apr 2008https://doi.org/10.1161/HYPERTENSIONAHA.107.108910Hypertension. 2008;51:1470–1471Other version(s) of this articleYou are viewing the most recent version of this article. Previous versions: April 21, 2008: Previous Version 1 The provocative proposition of "hypertension is a myth" has generated many a debate and editorial commentary.1,2 In contrast, the realities of high blood pressure and the associated cardiovascular risks have been ascertained from data obtained by the conventional brachial cuff sphygmomanometer. Notwithstanding the inherent limitations of the technique, there is yet no equivalent and suitable device that can be universally accepted to replace the cuff sphygmomanometer for practical and noninvasive measurement of arterial blood pressure in large population groups and with wide clinical applications. Attempts at complementing information obtained from cuff measurements have resorted to basic physiological studies in humans and experimental animals, which have shown that pulsatile blood flow in arteries can be described in terms of characteristics common to systems of wave propagation.3 These concepts explain the complex relationship between oscillatory blood pressure and flow, the difference in pressure wave shape, and the increase in pulse pressure between the aorta and peripheral arteries. Such wave propagation characteristics can be described in terms of mathematical entities known as transfer functions, with associated assumptions of stability and linearity.3,4The study by McEniery et al in this issue of Hypertension5 uses methodologies for both the cuff sphygmomanometer and transfer functions4 to determine central aortic pressure from the brachial cuff pressure measurement and the tonometric radial artery pressure pulse in >10 000 adults of age range 18 to 101 years. This is the largest study of its kind with conventional pressure measurements and pulse waveform data. The study allows analysis that can produce potentially groundbreaking results and poses important and possibly perplexing and challenging questions related not only to the role of central aortic pressure as an improved measure of the hemodynamic burden on the ejecting ventricle but also on the interpretation of guidelines for the management of hypertension as a cardiovascular risk factor with blood pressure as determined from the conventional brachial cuff.One of the main features of this study5 is that it addresses the difference in pulse pressure between the site of conventional measurement and the central aorta. The ratio of aortic pulse pressure to brachial pulse pressure is independent of calibration and depends only on the reliable detection of the peripheral pressure pulse and the methodology used to estimate the central aortic pressure pulse. The tonometric sensor used by the investigators has been used extensively in many other studies over the last 2 decades and can detect highly accurate signals from the radial artery and show age-related changes in the arterial pulse wave shape in human population groups in the hands of adequately trained operators.4 The study by McEniery et al5 would seem to have satisfied this requirement. The cited study validating the use of the brachial transfer function shows close agreement between measured and estimated central pressure.6 The relevant and important feature of this validation study is that it was done with simultaneous invasive measurements of both radial artery pressure and aortic pressure, using manometer systems with a high frequency response and external pressure sensors, which were referenced to atmospheric pressure. Thus, the calibration was done with actual gauge pressures with no confounding factors related to the relative height of pressure sensors or other systematic or random errors, as can occur even with high-fidelity intravascular catheter-tip transducers. Hence, the methodology used in this validation study6 was a specific validation of the mathematical transfer function used to generate the central aortic pressure waveform. This is different from validating the technique using a noninvasive radial pulse calibrated with a sphygmomanometric cuff pressure (and with the inherent associated errors) and then comparing the estimated values with measured central aortic pressure, because this incurs the inherent calibration errors that are independent of the transfer function but are part of the chain of the system components.The study5 found that, although the difference between peripheral and central pulse pressure decreases with age, it does not vanish in old age. It bottoms out in the age decade of 50 to 60 years, after which it is essentially constant, corresponding with an estimated average difference of 11 mm Hg in men an 8 mm Hg in women. Furthermore, for each age group, there is a considerable variability in the pulse pressure ratio. It is this variability that becomes relevant in determining the extent of overlap of central pressure values between the categories describing the various levels of blood pressure as defined by the recent European Society of Hypertension and of the European Society of Cardiology guidelines for management of hypertension.7 This is a crucial finding of the study, because the blood pressure bands in the guidelines are based entirely on the conventional measurement of brachial cuff pressure. Results indicate that, just on systolic values alone, there would be 32% of men and 10% of women who would be considered to have normal brachial systolic pressures and, therefore, not treated but would be classified as having stage 1 hypertension based on equivalent central aortic systolic pressure and, thus, would be considered for treatment. The numbers are much more striking when comparing the high-normal category and stage 1 hypertension, with 78% of men and 63% of women who would be considered to be in the high reference range of systolic pressure but would be considered to be hypertensive based on equivalent central pressure values. Although these proportions can be quite striking in terms of those that could be exposed to cardiovascular risk and not detected or treated, the opposite is also true, because the overlap is also relevant to those who would undergo treatment based on cuff pressure values but would fall under a lower risk category when assessed in terms of central pressures (although the study does not report these proportions).Recent studies have shown the importance of central aortic pressure and its implications in assessing the efficacy of antihypertensive treatment with respect to cardiovascular risk factors.8 Results of the study by McEniery et al5 highlight the issue of relating a measurement of brachial pressure to the categories in the guidelines, given this quite large range of overlap because of pulse amplification. The amplification is because of the frequency dependency of the transfer function,4,6 and because of the overall general stability of the transfer function, any difference in pulse amplification is attributable only to the frequency content of the pulse waveform, ie, the waveshape. An important implication of this study is that, whereas sphygmomanometric cuff pressure will continue to be used as the most practical surrogate measure of arterial blood pressure, other useful and potentially highly relevant information may be obtained from the registration of the arterial pulse waveform. Furthermore, whereas central pressure values may be estimated with regression models that do not necessarily include the time-varying pulse waveform, these do not explain the whole variation. Indeed, we have shown previously9 that stepwise multiple regression models, including height, weight, heart rate, systolic and diastolic cuff pressure, and age, explain 76% of the variability. This agrees with the figure of 73% obtained in the study by McEniery et al5 and implies that the entire peripheral pulse waveform is required for a reliable estimation of central aortic pressure. This has further implications on the heart rate dependency on pulse amplification10 in individual pressure measurements and subsequent classification according to the guidelines.The study by McEniery et al5 is timely, because there is a necessity to quantify the value of central aortic pressure, given the increasing interest in the field. The authors recognize some of the study limitations, such as its cross-sectional design, but the overall results indicate that it can form an important platform on which to launch further investigations on the relevance of central blood pressure. The study describes, for the first time, the unique feature of using the physiological phenomenon of the variable difference of the pulse pressure between the aorta and upper limb arteries. This is used to describe aging changes and to quantify the relevance of central aortic pressure estimated from measured values of conventional brachial cuff pressure.A general question raised by the study of McEniery et al5 is whether this and other similar studies could lead to a type of paradigm shift in the understanding of the relevance of conventional blood pressure measurement by the introduction of central aortic blood pressure. There is no question that, with the introduction of the brachial cuff and auscultatory techniques, Drs Scipione Riva-Roci and Nikolai Korotkoff caused a shift from essentially observation phenomena to quantification of the effects of blood pressure on cardiovascular disease by providing the ability to have numeric values for systolic and diastolic pressure and by the ubiquitous use of the sphygmomanometer throughout the 20th century. The addition, in the 21st century, of the earlier technology of sphygmography, pioneered during the 19th century,3 could provide a practical and potentially more powerful means for a better stratification of cardiovascular risk. With respect to the mythological propositions of hypertension or high blood pressure, one could well recall the remark of an earlier gazer of the heavens in the early 17th century, who put into question the long established Aristotelian geocentric view of the universe, and, when taken away to be imprisoned, is said to have whispered, sotto voce, "E pur si muove!" Whether these words were actually uttered by Gallileo Galilei or are entirely apocryphal, they do remind us that, whether we call it hypertension or high blood pressure, ultimately it is the truth that inevitably leads to paradigm shifts and not its mere perception from a distance.The opinions expressed in this editorial are not necessarily those of the editors or of the American Heart Association.DisclosuresNone.FootnotesCorrespondence to Alberto Avolio, Australian School of Advanced Medicine, Level 1, Dow Corning Building, 3 Innovation Rd, Macquarie University, NSW 2109, Australia. E-mail [email protected] References 1 Doyle AE. Hypertension: the realities. Aust N Z J Med. 1983; 13: 185–186.CrossrefMedlineGoogle Scholar2 O'Rourke MF. Hypertension is a myth; high(er) arterial pressure is the problem. Aust N Z J Med. 1984; 14: 69–70.CrossrefMedlineGoogle Scholar3 Nichols WW, O'Rourke MF. McDonald's Blood Flow in Arteries. 5th ed. London: Hodder Arnold: 2005.Google Scholar4 Chen CH, Nevo E, Fetics B, Pak PH, Yin FC, Maughan WL, Kass DA. Estimation of central aortic pressure waveform by mathematical transformation of radial tonometry pressure. Validation of generalized transfer function. Circulation. 1997; 95: 1827–1836.CrossrefMedlineGoogle Scholar5 McEniery CM, Yasmin, McDonnell B, Munnery M, Wallace SM, Rowe CV, Cockcroft JR, Wilkinson IB; on behalf of the Anglo-Cardiff Collaboration Trial Investigators. Central pressure: variability and impact of cardiovascular risk factors: the Anglo-Cardiff Collaborative Trial II. Hypertension. 2008; 51: 1476–1482.LinkGoogle Scholar6 Pauca AL, O'Rourke MF, Kon ND. Prospective evaluation of a method for estimating ascending aortic pressure from the radial artery pressure waveform. Hypertension. 2001; 38: 932–937.CrossrefMedlineGoogle Scholar7 Mancia G, De Backer G, Dominiczak A, Cifkova R, Fagard R, Germano G, Grassi G, Heagerty AM, Kjeldsen SE, Laurent S, Narkiewicz K, Ruilope L, Rynkiewicz A, Schmieder RE, Boudier HA, Zanchetti A; for the ESH-ESC Task Force on the Management of Arterial Hypertension. 2007 ESH-ESC Practice Guidelines for the Management of Arterial Hypertension: ESH-ESC Task Force on the Management of Arterial Hypertension. J Hypertens. 2007; 25: 1751–1762.CrossrefMedlineGoogle Scholar8 Williams B, Lacy PS, Thom SM, Cruickshank K, Stanton A, Collier D, Hughes AD, Thurston H, O'Rourke M. Differential impact of blood pressure-lowering drugs on central aortic pressure and clinical outcomes: principal results of the Conduit Artery Function Evaluation (CAFE) study. Circulation. 2006; 113: 1213–1225.LinkGoogle Scholar9 Camacho F, Avolio A, Lovell NH. Estimation of pressure pulse amplification between aorta and brachial artery using stepwise multiple regression models. Physiol Meas. 2004; 25: 879–889.CrossrefMedlineGoogle Scholar10 Wilkinson IB, Mohammad NH, Tyrrell S, Hall IR, Webb DJ, Paul VE, Levy T, Cockcroft JR. Heart rate dependency of pulse pressure amplification and arterial stiffness. Am J Hypertens. 2002; 15: 24–30.CrossrefMedlineGoogle Scholar Previous Back to top Next FiguresReferencesRelatedDetailsCited By (2022) Pulse Wave for Arterial Diagnostics Pressure Oscillation in Biomedical Diagnostics and Therapy, 10.1002/9781119265931.ch2, (15-70), Online publication date: 10-Oct-2022. Farooq A and Zhang P (2022) A comprehensive review on the prospects of next-generation wearable electronics for individualized health monitoring, assistive robotics, and communication, Sensors and Actuators A: Physical, 10.1016/j.sna.2022.113715, 344, (113715), Online publication date: 1-Sep-2022. Bikia V, Fong T, Climie R, Bruno R, Hametner B, Mayer C, Terentes-Printzios D and Charlton P (2021) Leveraging the potential of machine learning for assessing vascular ageing: state-of-the-art and future research, European Heart Journal - Digital Health, 10.1093/ehjdh/ztab089, 2:4, (676-690), Online publication date: 29-Dec-2022. Jiang X, Wu K, Luo J, Zhang L, Sun W and Xia X (2019) An A 1 -type granite that borders A 2 -type: insights from the geochemical characteristics of the Zongyang A-type granite in the Lower Yangtze River Belt, China , International Geology Review, 10.1080/00206814.2019.1689534, 62:17, (2203-2220), Online publication date: 21-Nov-2020. Bikia V, Papaioannou T, Pagoulatou S, Rovas G, Oikonomou E, Siasos G, Tousoulis D and Stergiopulos N (2020) Noninvasive estimation of aortic hemodynamics and cardiac contractility using machine learning, Scientific Reports, 10.1038/s41598-020-72147-8, 10:1 Del Giorno R, Ceresa C, Gabutti S, Troiani C and Gabutti L (2020) Arterial Stiffness and Central Hemodynamics are Associated with Low Diurnal Urinary Sodium Excretion, Diabetes, Metabolic Syndrome and Obesity: Targets and Therapy, 10.2147/DMSO.S266246, Volume 13, (3289-3299) Bikia V, Pagoulatou S, Trachet B, Soulis D, Protogerou A, Papaioannou T and Stergiopulos N Noninvasive Cardiac Output and Central Systolic Pressure From Cuff-Pressure and Pulse Wave Velocity, IEEE Journal of Biomedical and Health Informatics, 10.1109/JBHI.2019.2956604, 24:7, (1968-1981) Hui X, Conroy T and Kan E Multi-Point Near-Field RF Sensing of Blood Pressures and Heartbeat Dynamics, IEEE Access, 10.1109/ACCESS.2020.2993994, 8, (89935-89945) Forouzanmehr P, Haidary Sardaby E and Hesam S (2019) Investigating the Association of Relative Central Blood Pressure Indices and Severity of Coronary Artery Disease, Jundishapur Journal of Chronic Disease Care, 10.5812/jjcdc.97112, 8:4 Hong Y, Jeong H, Cho K, Lu N and Kim D (2019) Wearable and Implantable Devices for Cardiovascular Healthcare: from Monitoring to Therapy Based on Flexible and Stretchable Electronics, Advanced Functional Materials, 10.1002/adfm.201808247, 29:19, (1808247), Online publication date: 1-May-2019. Plat J, Severins N and Mensink R (2019) Improvement of pulse wave velocity and metabolic cardiovascular risk parameters through egg protein hydrolysate intake: A randomized trial in overweight or obese subjects with impaired glucose tolerance or type 2 diabetes, Journal of Functional Foods, 10.1016/j.jff.2018.11.020, 52, (418-423), Online publication date: 1-Jan-2019. Kozakova M, Boutouyrie P, Morizzo C, Latta D, Jamagidze G, Chiappino D, Laurent S and Palombo C (2018) Radiofrequency-based wall tracking for noninvasive assessment of local carotid pulse pressure, Journal of Hypertension, 10.1097/HJH.0000000000001837, 36:12, (2362-2368), Online publication date: 1-Dec-2018. Leitão C, Antunes P, Pinto J, Bastos J and André P (2017) Carotid distension waves acquired with a fiber sensor as an alternative to tonometry for central arterial systolic pressure assessment in young subjects, Measurement, 10.1016/j.measurement.2016.09.035, 95, (45-49), Online publication date: 1-Jan-2017. Leitão C, Antunes P, Pinto J, Mesquita Bastos J and André P (2016) Optical fiber sensors for central arterial pressure monitoring, Optical and Quantum Electronics, 10.1007/s11082-016-0494-1, 48:3, Online publication date: 1-Mar-2016. CHEN G, WANG X, ZHANG Y, RU X, ZHOU L and TIAN Y (2015)(2015) H3K9 histone methyltransferase G9a ameliorates dilated cardiomyopathy via the downregulation of cell adhesion molecules, Molecular Medicine Reports, 10.3892/mmr.2015.3218, 11:5, (3872-3879), Online publication date: 1-May-2015. Avolio A and Butlin M (2015) Dependence of arterial stiffness on pressure quantified in the realm of the cardiac cycle, Journal of Hypertension, 10.1097/HJH.0000000000000443, 33:2, (257-259), Online publication date: 1-Feb-2015. Avolio A (2013) Central Aortic Blood Pressure and Management of Hypertension, Hypertension, 62:6, (1005-1007), Online publication date: 1-Dec-2013. Regnault V, Thomas F, Safar M, Osborne-Pellegrin M, Khalil R, Pannier B and Lacolley P (2012) Sex Difference in Cardiovascular Risk, Journal of the American College of Cardiology, 10.1016/j.jacc.2012.01.044, 59:20, (1771-1777), Online publication date: 1-May-2012. Benetos A, Salvi P and Lacolley P (2011) Blood pressure regulation during the aging process: the end of the 'hypertension era'?, Journal of Hypertension, 10.1097/HJH.0b013e3283424be0, 29:4, (646-652), Online publication date: 1-Apr-2011. Bia D, Zócalo Y, Farro I, Torrado J, Farro F, Florio L, Olascoaga A, Brum J, Alallón W, Negreira C, Lluberas R and Armentano R (2011) Integrated Evaluation of Age-Related Changes in Structural and Functional Vascular Parameters Used to Assess Arterial Aging, Subclinical Atherosclerosis, and Cardiovascular Risk in Uruguayan Adults: CUiiDARTE Project, International Journal of Hypertension, 10.4061/2011/587303, 2011, (1-12), . Salvi P, Safar M, Labat C, Borghi C, Lacolley P and Benetos A (2010) Heart disease and changes in pulse wave velocity and pulse pressure amplification in the elderly over 80 years: the PARTAGE Study, Journal of Hypertension, 10.1097/HJH.0b013e32833c48de, 28:10, (2127-2133), Online publication date: 1-Oct-2010. Benetos A, Thomas F, Joly L, Blacher J, Pannier B, Labat C, Salvi P, Smulyan H and Safar M (2010) Pulse Pressure Amplification, Journal of the American College of Cardiology, 10.1016/j.jacc.2009.09.061, 55:10, (1032-1037), Online publication date: 1-Mar-2010. Avolio A, Butlin M and Walsh A (2009) Arterial blood pressure measurement and pulse wave analysis-–their role in enhancing cardiovascular assessment, Physiological Measurement, 10.1088/0967-3334/31/1/R01, 31:1, (R1-R47), Online publication date: 1-Jan-2010. Namasivayam M, McDonnell B, McEniery C and O'Rourke M (2009) Does Wave Reflection Dominate Age-Related Change in Aortic Blood Pressure Across the Human Life Span?, Hypertension, 53:6, (979-985), Online publication date: 1-Jun-2009. Avolio A and Grassi G (2008) Flow-mediated dilatation as a biomarker for cardiovascular risk in hypertension, Journal of Hypertension, 10.1097/HJH.0b013e32830b5f50, 26:8, (1546-1547), Online publication date: 1-Aug-2008. June 2008Vol 51, Issue 6 Advertisement Article InformationMetrics https://doi.org/10.1161/HYPERTENSIONAHA.107.108910PMID: 18426994 Originally publishedApril 21, 2008 PDF download Advertisement SubjectsHypertension

Referência(s)
Altmetric
PlumX