Determinação de corantes marcadores do tipo azo e antraquinona em combustíveis por cromatografia líquida com detecção eletroquímica
2010; Brazilian Chemical Society; Volume: 33; Issue: 1 Linguagem: Inglês
10.1590/s0100-40422010000100027
ISSN1678-7064
AutoresMagno Aparecido Gonçalves Trindade, Daniel Rinaldo, Wagner Vilegas, María Valnice Boldrin Zanoni,
Tópico(s)Dye analysis and toxicity
ResumoSAMPLE USING HPLC WITH ELECTROCHEMICAL DETECTION.An analytical method based on high-performance liquid chromatography with electrochemical detection has been developed and applied to the determination of Solvent blue 14 (SA-14) and Solvent red 24 (SV-24) in fuel samples.The dyes were better separated on C18 column, using a mobile phase composed of acetonitrile and ammonium acetate (90:10, v/v).Detection was carried out at an oxidation potential of +0.85V.The detector response was linear at concentration range of 7.50×10 -8 -1.50×10 -6 mol L -1 (r = 0.997) for SA-14 and SV-24, respectively.The method was used to quantify these dyes in fuels samples with satisfactory accuracy and precision.
Referência(s)