Artigo Acesso aberto Revisado por pares

Fibrin Clot Visualized by Optical Coherence Tomography

2008; Lippincott Williams & Wilkins; Volume: 118; Issue: 4 Linguagem: Inglês

10.1161/circulationaha.107.749564

ISSN

1524-4539

Autores

Teruyoshi Kume, Hiroyuki Okura, Takahiro Kawamoto, Takashi Akasaka, Eiji Toyota, Nozomi Watanabe, Yoji Neishi, Yoshito Sadahira, Kiyoshi Yoshida,

Tópico(s)

Cerebrovascular and Carotid Artery Diseases

Resumo

HomeCirculationVol. 118, No. 4Fibrin Clot Visualized by Optical Coherence Tomography Free AccessReview ArticlePDF/EPUBAboutView PDFView EPUBSections ToolsAdd to favoritesDownload citationsTrack citationsPermissions ShareShare onFacebookTwitterLinked InMendeleyReddit Jump toFree AccessReview ArticlePDF/EPUBFibrin Clot Visualized by Optical Coherence Tomography Teruyoshi Kume, MD, Hiroyuki Okura, MD, Takahiro Kawamoto, MD, Takashi Akasaka, MD, Eiji Toyota, MD, Nozomi Watanabe, MD, Yoji Neishi, MD, Yoshito Sadahira, MD and Kiyoshi Yoshida, MD Teruyoshi KumeTeruyoshi Kume From the Department of Cardiology (T. Kume, H.O., T. Kawamoto, E.T., N.W., Y.N., K.Y.) and Department of Pathology (Y.S.), Kawasaki Medical School, Kurashiki, Japan; and Department of Cardiology, Wakayama Medical University, Wakayama, Japan (T.A.). , Hiroyuki OkuraHiroyuki Okura From the Department of Cardiology (T. Kume, H.O., T. Kawamoto, E.T., N.W., Y.N., K.Y.) and Department of Pathology (Y.S.), Kawasaki Medical School, Kurashiki, Japan; and Department of Cardiology, Wakayama Medical University, Wakayama, Japan (T.A.). , Takahiro KawamotoTakahiro Kawamoto From the Department of Cardiology (T. Kume, H.O., T. Kawamoto, E.T., N.W., Y.N., K.Y.) and Department of Pathology (Y.S.), Kawasaki Medical School, Kurashiki, Japan; and Department of Cardiology, Wakayama Medical University, Wakayama, Japan (T.A.). , Takashi AkasakaTakashi Akasaka From the Department of Cardiology (T. Kume, H.O., T. Kawamoto, E.T., N.W., Y.N., K.Y.) and Department of Pathology (Y.S.), Kawasaki Medical School, Kurashiki, Japan; and Department of Cardiology, Wakayama Medical University, Wakayama, Japan (T.A.). , Eiji ToyotaEiji Toyota From the Department of Cardiology (T. Kume, H.O., T. Kawamoto, E.T., N.W., Y.N., K.Y.) and Department of Pathology (Y.S.), Kawasaki Medical School, Kurashiki, Japan; and Department of Cardiology, Wakayama Medical University, Wakayama, Japan (T.A.). , Nozomi WatanabeNozomi Watanabe From the Department of Cardiology (T. Kume, H.O., T. Kawamoto, E.T., N.W., Y.N., K.Y.) and Department of Pathology (Y.S.), Kawasaki Medical School, Kurashiki, Japan; and Department of Cardiology, Wakayama Medical University, Wakayama, Japan (T.A.). , Yoji NeishiYoji Neishi From the Department of Cardiology (T. Kume, H.O., T. Kawamoto, E.T., N.W., Y.N., K.Y.) and Department of Pathology (Y.S.), Kawasaki Medical School, Kurashiki, Japan; and Department of Cardiology, Wakayama Medical University, Wakayama, Japan (T.A.). , Yoshito SadahiraYoshito Sadahira From the Department of Cardiology (T. Kume, H.O., T. Kawamoto, E.T., N.W., Y.N., K.Y.) and Department of Pathology (Y.S.), Kawasaki Medical School, Kurashiki, Japan; and Department of Cardiology, Wakayama Medical University, Wakayama, Japan (T.A.). and Kiyoshi YoshidaKiyoshi Yoshida From the Department of Cardiology (T. Kume, H.O., T. Kawamoto, E.T., N.W., Y.N., K.Y.) and Department of Pathology (Y.S.), Kawasaki Medical School, Kurashiki, Japan; and Department of Cardiology, Wakayama Medical University, Wakayama, Japan (T.A.). Originally published22 Jul 2008https://doi.org/10.1161/CIRCULATIONAHA.107.749564Circulation. 2008;118:426–427Optical coherence tomography (OCT) is a recently developed optical imaging technique that provides high-resolution (≈10 to 20 μm) cross-sectional images of vessels.1 It has been reported that OCT images of white and red thrombus were characterized as backscattering protrusions in the coronary lumen.2 However, OCT characteristics of fibrin clot composed of fibrin material and few blood cells have not been described.The coronary arteries of a 75-year-old man who died from acute myocardial infarction were obtained at autopsy. Histopathological examination showed fibrin clot composed of fibrin material and few blood cells in the coronary artery (Figure, A and B). Before proceeding with a standard histopathological examination, we visualized the coronary artery using OCT. OCT characteristics of fibrin clot, a signal-rich structure without backscattering, were obviously different from white or red thrombus that were characterized as a signal-rich structure with backscattering (Figure, C). Download figureDownload PowerPointFigure. Correlation between optical OCT images (C, F, and I) and histological examinations of human coronary fibrin clot (A and B), red thrombus (D and E), and white thrombus (G and H) obtained at autopsy. A and B, Fibrin clot was composed of fibrin material and few blood cells. *Fibrin clot, hematoxylin and eosin stain. D and E, Red thrombus (RT) consisted mainly of red blood cells (hematoxylin and eosin stain). H and I, White thrombus (WT) consisted mainly of platelets, fibrin, and white blood celld (hematoxylin and eosin stain). C, OCT image of fibrin clot was characterized as a signal-rich structure without backscattering. *Fibrin clot. F and I. OCT images of red and white thrombi were visualized as a signal-rich structure with backscattering (RT indicates red thrombus; WT; white thrombus).Although drug-eluting stents have reduced rates of restenosis and late lumen loss compared with bare-metal stents, thrombosis has emerged as a major concern. In addition, delayed arterial healing, as evidenced by persistence of fibrin clot after DES implantation, has been demonstrated. Although OCT might be useful for monitoring structural changes after DES implantation, it might be difficult, using OCT, to discriminate fibrin clot from minimal neointimal formation after DES implantation.DisclosuresNone.FootnotesCorrespondence to Hiroyuki Okura, MD, Department of Cardiology, Kawasaki Medical School, 577 Matsushima, Kurashiki, 701–0192, Japan. E-mail [email protected]References1 Kume T, Akasaka T, Kawamoto T, Watanabe N, Toyota E, Neishi N, Sukmawan R, Sadahira Y, Yoshida K. Assessment of coronary arterial plaque by optical coherence tomography. Am J Cardiol. 2006; 97: 1172–1175.CrossrefMedlineGoogle Scholar2 Kume T, Akasaka T, Kawamoto T, Ogasawara Y, Watanabe N, Toyota E, Neishi N, Sukmawan R, Sadahira Y, Yoshida K. Assessment of coronary arterial thrombus by optical coherence tomography. Am J Cardiol. 2006; 97: 1713–1717.CrossrefMedlineGoogle Scholar Previous Back to top Next FiguresReferencesRelatedDetailsCited By Adriaenssens T (2020) Basic Interpretation Skills Cardiovascular OCT Imaging, 10.1007/978-3-030-25711-8_3, (37-52), . Noukeu L, Wolf J, Yuan B, Banerjee S and Nguyen K (2018) Nanoparticles for Detection and Treatment of Peripheral Arterial Disease, Small, 10.1002/smll.201800644, 14:32, (1800644), Online publication date: 1-Aug-2018. Jaguszewski M, Aloysius R, Wang W, Bezerra H, Hill J, De Winter R, Karjalainen P, Verheye S, Wijns W, Lüscher T, Joner M, Costa M and Landmesser U (2017) The REMEDEE-OCT Study, JACC: Cardiovascular Interventions, 10.1016/j.jcin.2016.11.040, 10:5, (489-499), Online publication date: 1-Mar-2017. Jinnouchi H, Kuramitsu S, Shinozaki T, Tomoi Y, Hiromasa T, Kobayashi Y, Domei T, Soga Y, Hyodo M, Shirai S and Ando K (2017) Difference of Tissue Characteristics Between Early and Late Restenosis After Second-Generation Drug-Eluting Stents Implantation ― An Optical Coherence Tomography Study ―, Circulation Journal, 10.1253/circj.CJ-16-1069, 81:4, (450-457), . Ughi G and Adriaenssens T (2017) Intracoronary Optical Coherence Tomography Computing and Visualization for Intravascular Imaging and Computer-Assisted Stenting, 10.1016/B978-0-12-811018-8.00008-4, (183-223), . Affanni A, Chiorboli G, Specogna R and Trevisan F (2016) Uncertainty model of electro-optical thrombus growth estimation for early risk detection, Measurement, 10.1016/j.measurement.2015.05.045, 79, (260-266), Online publication date: 1-Feb-2016. Wijns W, Vrolix M, Verheye S, Schoors D, Slagboom T, Gosselink M, Benit E, Donohoe D, Knape C, Attizzani G, Lansky A and Ormiston J (2015) Randomised study of a bioabsorbable polymer-coated sirolimus-eluting stent: results of the DESSOLVE II trial, EuroIntervention, 10.4244/EIJY14M05_03, 10:12, (1383-1390), Online publication date: 1-Apr-2015. Rassi A, O'Dea J, Jia H, Seto A and Jang I (2014) Nonangiographic assessment of coronary artery disease, Coronary Artery Disease, 10.1097/MCA.0000000000000173, 25:7, (608-618), Online publication date: 1-Nov-2014. Attizzani G, Bezerra H, Ormiston J, Wang W, Donohoe D, Wijns W and Costa M (2013) Serial Assessment by Optical Coherence Tomography of Early and Late Vascular Responses After Implantation of an Absorbable-Coating Sirolimus-Eluting Stent (from the First-in-Human DESSOLVE I Trial), The American Journal of Cardiology, 10.1016/j.amjcard.2013.07.013, 112:10, (1557-1564), Online publication date: 1-Nov-2013. Goto K, Takebayashi H, Kihara Y, Hagikura A, Fujiwara Y, Kikuta Y, Sato K, Kodama S, Taniguchi M, Hiramatsu S and Haruta S (2013) Appearance of neointima according to stent type and restenotic phase: analysis by optical coherence tomography, EuroIntervention, 10.4244/EIJV9I5A96, 9:5, (601-607), Online publication date: 1-Sep-2013. Guagliumi G, Akasaka T, Sirbu V and Kubo T (2012) Optical Coherence Tomography Textbook of Interventional Cardiology, 10.1016/B978-1-4377-2358-8.00060-7, (842-857), . Couture L, Richer L, Cadieux C, Thomson C and Hossain S (2011) An optimized method to assess in vivo efficacy of antithrombotic drugs using optical coherence tomography and a modified Doppler flow system, Journal of Pharmacological and Toxicological Methods, 10.1016/j.vascn.2011.09.001, 64:3, (264-268), Online publication date: 1-Nov-2011. Takarada S, Kern M and Akasaka T (2011) Intracoronary Optical Frequency Domain Imaging for Identifying Stent-Related Complications, Current Cardiovascular Imaging Reports, 10.1007/s12410-011-9088-2, 4:4, (292-297), Online publication date: 1-Aug-2011. Escaned J and Gonzalo N (2011) Lessons learned from advanced intracoronary imaging in patients with acute myocardial infarction, Journal of Cardiovascular Medicine, 10.2459/JCM.0b013e32834da56a, 12:12, (868-877), Online publication date: 1-Dec-2011. Guagliumi G, Sirbu V, Musumeci G, Bezerra H, Aprile A, Kyono H, Fiocca L, Matiashvili A, Lortkipanidze N, Vassileva A, Popma J, Allocco D, Dawkins K, Valsecchi O and Costa M (2010) Strut Coverage and Vessel Wall Response to a New-Generation Paclitaxel-Eluting Stent With an Ultrathin Biodegradable Abluminal Polymer, Circulation: Cardiovascular Interventions, 3:4, (367-375), Online publication date: 1-Aug-2010. Ozaki Y, Okumura M, Ismail T, Naruse H, Hattori K, Kan S, Ishikawa M, Kawai T, Takagi Y, Ishii J, Prati F and Serruys P (2010) The fate of incomplete stent apposition with drug-eluting stents: an optical coherence tomography-based natural history study, European Heart Journal, 10.1093/eurheartj/ehq066, 31:12, (1470-1476), Online publication date: 2-Jun-2010. Guagliumi G, Sirbu V, Bezerra H, Biondi-Zoccai G, Fiocca L, Musumeci G, Matiashvili A, Lortkipanidze N, Tahara S, Valsecchi O and Costa M (2010) Strut Coverage and Vessel Wall Response to Zotarolimus-Eluting and Bare-Metal Stents Implanted in Patients With ST-Segment Elevation Myocardial Infarction, JACC: Cardiovascular Interventions, 10.1016/j.jcin.2010.04.005, 3:6, (680-687), Online publication date: 1-Jun-2010. Fusazaki T, Itoh T, Koeda T, Kimura T, Ogino Y, Matsui H, Sugawara S and Nakamura M (2010) Angioscopy and OCT in Repeated In-Stent Restenosis in Saphenous Vein Graft, JACC: Cardiovascular Imaging, 10.1016/j.jcmg.2009.10.014, 3:7, (785-786), Online publication date: 1-Jul-2010. Itoh T, Fusazaki T, Kimura T, Ogino Y, Matsui H, Sugawara S, Goto I and Nakamura M (2009) "Intracoronary Whirling Current Phenomenon" and Thrombus Formation After Sirolimus-Eluting Stent Implantation Visualized by Optical Coherence Tomography, Circulation: Cardiovascular Interventions, 2:3, (264-267), Online publication date: 1-Jun-2009. Takano M, Mizuno K, Kim S and Jang I (2009) Optical coherence tomography, Current Cardiovascular Imaging Reports, 10.1007/s12410-009-0032-7, 2:4, (275-283), Online publication date: 1-Aug-2009. Guagliumi G and Costa M (2009) From a Foggy Sight to a Clear Vision⁎⁎Editorials published in JACC: Cardiovascular Interventions reflect the views of the authors and do not necessarily represent the views of JACC: Cardiovascular Interventions or the American College of Cardiology., JACC: Cardiovascular Interventions, 10.1016/j.jcin.2009.03.006, 2:5, (467-469), Online publication date: 1-May-2009. July 22, 2008Vol 118, Issue 4 Advertisement Article InformationMetrics https://doi.org/10.1161/CIRCULATIONAHA.107.749564PMID: 18645069 Originally publishedJuly 22, 2008 PDF download Advertisement SubjectsImagingThrombosis

Referência(s)
Altmetric
PlumX