Dead-Time Elimination for Voltage Source Inverters
2008; Institute of Electrical and Electronics Engineers; Volume: 23; Issue: 2 Linguagem: Inglês
10.1109/tpel.2007.915766
ISSN1941-0107
Autores Tópico(s)Photovoltaic System Optimization Techniques
ResumoA novel dead-time elimination method is presented in this paper for voltage source inverters. This method is based on decomposing of a generic phase-leg into two basic switching cells, which are configured with a controllable switch in series with an uncontrollable diode. Therefore, dead-time is not needed. In comparison to using expensive current sensors, this method precisely determines the load current direction by detecting which anti-parallel diode conducts in a phase-leg. A low-cost diode-conduction detector is developed to measure the operating state of the anti-parallel diode. In comparison with complicated compensators, this method features simple logic and flexible implementation. This method significantly reduces the output distortion and regains the output RMS value. The principle of the proposed dead-time elimination method is described in detail. Simulation and experimental results are given to demonstrate the validity and features of this new method.
Referência(s)