Artigo Acesso aberto Revisado por pares

Assessment of aortic regurgitation by transesophageal color Doppler imaging of the vena contracta: validation against an intraoperative aortic flow probe

2001; Elsevier BV; Volume: 37; Issue: 5 Linguagem: Inglês

10.1016/s0735-1097(01)01114-7

ISSN

1558-3597

Autores

DuWayne L. Willett, Shelley Hall, Michael E. Jessen, Michael A. Wait, Paul Grayburn,

Tópico(s)

Pulmonary Hypertension Research and Treatments

Resumo

OBJECTIVES This study was performed to validate the accuracy of color flow vena contracta (VC) measurements of aortic regurgitation (AR) severity by comparing them to simultaneous intraoperative flow probe measurements of regurgitant fraction (RgF) and regurgitant volume (RgV). BACKGROUND Color Doppler imaging of the vena contracta has emerged as a simple and reliable measure of the severity of valvular regurgitation. This study evaluated the accuracy of VC imaging of AR by transesophageal echocardiography (TEE). METHODS A transit-time flow probe was placed on the ascending aorta during cardiac surgery in 24 patients with AR. The flow probe was used to measure RgF and RgV simultaneously during VC imaging by TEE. Flow probe and VC imaging were interpreted separately and in blinded fashion. RESULTS A good correlation was found between VC width and RgF (r = 0.85) and RgV (r = 0.79). All six patients with VC width >6 mm had a RgF >0.50. All 18 patients with VC width <5 mm had a RgF 7.5 mm2had a RgF >0.50, and all 18 patients with a VC area <7.5 mm2had a RgF <0.50. In a subset of nine patients who underwent afterload manipulation to increase diastolic blood pressure, RgV increased significantly (34 ± 26 ml to 41 ± 27 ml, p = 0.042) while VC width remained unchanged (5.4 ± 2.8 mm to 5.4 ± 2.8 mm, p = 0.41). CONCLUSIONS Vena contracta imaging by TEE color flow mapping is an accurate marker of AR severity. Vena contracta width and VC area correlate well with RgF and RgV obtained by intraoperative flow probe. Vena contracta width appears to be less afterload-dependent than RgV.

Referência(s)