Ultraviolet radiation compared to an ultra-clean air enclosure. Comparison of air bacteria counts in operating rooms
1991; British Editorial Society of Bone & Joint Surgery; Volume: 73-B; Issue: 5 Linguagem: Inglês
10.1302/0301-620x.73b5.1894672
ISSN2044-5377
AutoresMark A. Berg, B. Bergman, J Hoborn,
Tópico(s)Surgical site infection prevention
ResumoClean air in the operating room is important during joint replacement surgery. We compared monochromatic ultraviolet radiation of 254 nm with the use of a Charnley-Howorth air enclosure by bacterial air-sampling during 113 total hip arthroplasties. Air samples were taken continuously at the edge of the wound and every 15 minutes at a site 130 cm from the operating table. We also tested the effect of occlusive clothing for all personnel. Ultraviolet light was more efficient than the ultra-clean air enclosure, and occlusive clothing on its own or in combination also produced improvement. The implications of these findings are discussed.