Scintigraphic demonstration of ventriculo atrial conduction in the ventricular pacemaker syndrome.
1982; National Institutes of Health; Volume: 23; Issue: 9 Linguagem: Inglês
Autores
Mark Rabinovitch, James R. Stewart, William W.‐C. Chan, Thomas E Dunlap, Victor Kalff, J. Fowler Clare, James H. Thrall, Bertram Pitt,
Tópico(s)Cardiovascular Effects of Exercise
ResumoA patient with the sick-sinus syndrome was evaluated because of symptomatic deterioration after insertion of a ventricular demand pacemaker. Clinical features of the ventricular pacemaker syndrome were recognized and confirmed by electrophysiological and hemodynamic studies. Phase analysis--a new technique for detecting patterns of cardiac emptying from gated cardiac blood-pool scintigrams--demonstrated a pattern consistent with 1:1 ventriculo-atrial conduction. Phase analysis of the gated cardiac blood-pool scintigram may be useful in the assessment of patients with ventricular demand pacemakers who complain of fatigue and effort intolerance.