Real‐time B ‐mode ultrasound quality control test procedures. Report of AAPM Ultrasound Task Group No. 1
1998; Wiley; Volume: 25; Issue: 8 Linguagem: Inglês
10.1118/1.598404
ISSN2473-4209
AutoresMitchell M. Goodsitt, Paul L. Carson, Scott Witt, D. L. Hykes, James M. Kofler,
Tópico(s)Ultrasound in Clinical Applications
ResumoMedical PhysicsVolume 25, Issue 8 p. 1385-1406 Open Access Real-time B-mode ultrasound quality control test procedures. Report of AAPM Ultrasound Task Group No. 1 Mitchell M. Goodsitt, Mitchell M. Goodsitt Department of Radiology, University of Michigan, Ann Arbor, Michigan 48109-0030Search for more papers by this authorPaul L. Carson, Paul L. Carson Department of Radiology, University of Michigan, Ann Arbor, Michigan 48109-0030Search for more papers by this authorScott Witt, Scott Witt Gammex RMI, Middleton, Wisconsin 53562-0327Search for more papers by this authorDavid L. Hykes, David L. Hykes Department of Radiation Therapy, St. Joseph Hospital and Health Center, Lorain, Ohio 44052Search for more papers by this authorJames M. Kofler Jr., James M. Kofler Jr. Department of Radiology, Mayo Clinic, Rochester, Minnesota 55904Search for more papers by this author Mitchell M. Goodsitt, Mitchell M. Goodsitt Department of Radiology, University of Michigan, Ann Arbor, Michigan 48109-0030Search for more papers by this authorPaul L. Carson, Paul L. Carson Department of Radiology, University of Michigan, Ann Arbor, Michigan 48109-0030Search for more papers by this authorScott Witt, Scott Witt Gammex RMI, Middleton, Wisconsin 53562-0327Search for more papers by this authorDavid L. Hykes, David L. Hykes Department of Radiation Therapy, St. Joseph Hospital and Health Center, Lorain, Ohio 44052Search for more papers by this authorJames M. Kofler Jr., James M. Kofler Jr. Department of Radiology, Mayo Clinic, Rochester, Minnesota 55904Search for more papers by this author First published: 23 October 1998 https://doi.org/10.1118/1.598404Citations: 111AboutPDF ToolsRequest permissionExport citationAdd to favoritesTrack citation ShareShare Give accessShare full text accessShare full-text accessPlease review our Terms and Conditions of Use and check box below to share full-text version of article.I have read and accept the Wiley Online Library Terms and Conditions of UseShareable LinkUse the link below to share a full-text version of this article with your friends and colleagues. Learn more.Copy URL REFERENCES 1J. E. Gray, N. T. Winkler, J. Stears, and E. D. Frank, Quality Control in Diagnostic Imaging (Aspen, Rockville, MD, 1983). 2NCRP Report No. 99, “Quality assurance for diagnostic imaging. National Council on Radiation Protection and Measurements,” National Council on Radiation Protection, Bethesda, MD, 1988. 3AIUM, Methods For Measuring Performance Of Pulse-Echo Ultrasound Equipment-Part II: Digital Methods (Stage 1), edited by H. Lopez et al. (American Institute of Ultrasound In Medicine, Laurel, MD, 1995). 4AIUM, Quality Assurance Manual for Gray Scale Ultrasound Scanners (Stage 2), edited by E. Madsen et al. (American Institute of Ultrasound In Medicine, Laurel, MD, 1995). 5The Ultrasound QA Cookbook (Gammex RMI, Middleton, WI, 1994). 6Mammography Quality Control Manual, revised edition (American College of Radiology, Reston, VA, 1994). 7J. M. Kofler, J. E. Gray, J. T. Fuelberth, and J. P. Taubel, “Quantitative evaluation of low-cost frame-grabber boards for personal computers,” J. Digital Imaging 8, 191– 197 (1995). 8J. J. Rownd, E. L. Madsen, J. A. Zagzebski, G. R. Frank, and F. Dong, “Phantoms and automated system for testing the resolution of ultrasound scanners,” Ultrasound Med. Biol. 23, 245– 260 (1997). 9J. E. Gray, K. G. Lisk, D. H. Haddick, J. H. Harshbarger, A. Oosterhof, and R. Schwencker, “Test pattern for video displays and hard-copy cameras,” Radiology 154, 519– 527 (1985). Citing Literature Volume25, Issue8August 1998Pages 1385-1406 This article also appears in:Online Learning Quizzes (TG Reports) ReferencesRelatedInformation
Referência(s)