Carta Acesso aberto Revisado por pares

Computerized Interpretation of ECGs

2013; Lippincott Williams & Wilkins; Volume: 6; Issue: 1 Linguagem: Inglês

10.1161/circep.111.000097

ISSN

1941-3149

Autores

N.A. Mark Estes,

Tópico(s)

Cardiac electrophysiology and arrhythmias

Resumo

HomeCirculation: Arrhythmia and ElectrophysiologyVol. 6, No. 1Computerized Interpretation of ECGs Free AccessEditorialPDF/EPUBAboutView PDFView EPUBSections ToolsAdd to favoritesDownload citationsTrack citationsPermissions ShareShare onFacebookTwitterLinked InMendeleyReddit Jump toFree AccessEditorialPDF/EPUBComputerized Interpretation of ECGsSupplement Not a Substitute N.A. Mark EstesIII, MD N.A. Mark EstesIIIN.A. Mark EstesIII From the Tufts University School of Medicine, Boston, MA. Originally published1 Feb 2013https://doi.org/10.1161/CIRCEP.111.000097Circulation: Arrhythmia and Electrophysiology. 2013;6:2–4IntroductionSince the introduction of the string galvanometer by Willem Einthoven more than a century ago, the ECG has become the most commonly performed cardiovascular test and an essential diagnostic tool in clinical cardiology.1–3 The transition from analogue to digital ECGs resulted in automated computer analysis of the ECG (ECG-C) assuming a larger role in the diagnostic interpretation.3 Yet, as the ECG-C has evolved into a necessary tool of modern medical practice, many physicians remain unaware of the hazards of relying on these preliminary diagnostic interpretations. The ECG-C clinical use should always be with the understanding that they are preliminary interpretations and require reading and confirmation by qualified electrocardiographer.3 With an increased reliance on these readings for point-of-care decision making, clinicians must remain mindful of many limitations of the ECG-C.2,3Article see p 76Multiple prior investigations on the ECG-C interpretation have demonstrated erroneous interpretation, resulting in unnecessary, potentially harmful medical treatment, and inappropriate use of medical resources.4–7 A large international study compared the performance of 9 ECG-C programs with that of cardiologists in interpreting ECGs in clinically validated cases of various cardiac disorders.4 The percentage of ECGs correctly classified by the ECG-C was lower than that for the cardiologists.4 The median sensitivity of the computer programs was also significantly lower than that of the cardiologists in diagnosing left ventricular hypertrophy, right ventricular hypertrophy, anterior myocardial infarction, and inferior myocardial infarction.4 The median total accuracy level (the percentage of correct classifications) was 6.6% lower for the computer programs (69.7%) than for the cardiologists (76.3%; P<0.001).4More contemporary analysis of the accuracy of ECG-C similarly concluded that there are frequent errors in the interpretation of the cardiac rhythm. In evaluating the ECG-C interpretation of the cardiac rhythm, the ECG-C demonstrated an overall accuracy of 88.0%.5 Sinus rhythm was correctly interpreted in 95.0% of the ECGs with this rhythm. However, nonsinus rhythms were correctly interpreted with an accuracy of only 54%.5 The ECG-C interpreted sinus rhythm with a sensitivity of 95%, specificity of 66.3%, and positive predictive value of 93.2%.5 The ECG-C interpreted nonsinus rhythms with a sensitivity of 72%, a specificity of 93%, and a positive predictive value of 59.3%.5 In addition, incorrect rhythm interpretation by the ECG-C was frequently further compounded by additional major inaccuracies.5 Of incorrect rhythm interpretation, additional major errors were noted in 137 (54%) patients.5The clinical impact of the ECG-C misinterpretation was evaluated by other investigators who demonstrated that 19% of ECG-C had the rhythm misinterpreted as atrial fibrillation.6 Failure of the physician ordering the ECG to correct the inaccurate interpretation resulted in change in management and initiation of inappropriate treatment, including antiarrhytmic medications and anticoagulation, in 10% of patients.6 Additional unnecessary diagnostic testing was performed based on the misinterpreted ECGs in 24% of patients.6The ECG-C failed to identify many at-risk family members when used as a screening tool for long QT syndrome (LQTS).7 The ECG-C erroneously classified 6 of 23 family members known to have LQTS as normal.7 Half of the family members, proved to have the ion channel defect, received the diagnostic interpretation normal ECG.7 The investigators concluded that reliance on the ECG-C alone fails to identify many at-risk family members with LQTS.7 The investigators suggested that all first-degree relatives of an identified LQTS proband have a 12-lead ECG that is reviewed independently by a physician who is familiar with LQTS in an effort to improve screening for this potentially lethal syndrome.7Accurate measurement of the QT interval and its adjustment for rate, sex, and QRS prolongation remains one of the major challenges in electrocardiography.3,8–13 The matter is of great importance to physicians, drug manufacturers, and regulatory agencies because of the relationship between prolongation of the QT interval and potentially lethal ventricular arrhythmias.3,8–13 In this respect, the original contribution by Lehman and his colleagues in this issue of Circulation, Arrhythmias and Electrophysiology has particular significance.14 In this investigation, all ECG-Cs analyzed by a single system (Marquette 12SL ECG Analysis Program, GE Healthcare, Milwaukee, WI) were evaluated. ECGs were included if sinus rhythm was present with a heart rate <100 beats per minute and QRS duration <120 ms.14 Of 97 046 study ECGs (48.2% from men), a prolonged ECG-C QTc value was displayed in 16.7%.14 The ECG-C used an algorithm that defined the range of normal for the QT interval as <470 ms in women, and <460 ms in men.14 However, in only 47.5% of these ECGs with prolonged QTc did the automated interpretation include an accompanying prolonged QT diagnostic statement.14 The authors note that such prolonged QT under-reporting was manifest across all patient environments, and reflected algorithmic suppression of the diagnosis.14 This was because of ECG waveform-based criteria in 52.5% of ECGs with prolonged QTc.14 Of the latter ECGs with prolonged QT diagnosis suppression, the computer declared 42.1% as normal, despite QTc prolongation.14 The authors concluded that in evaluating an adult patient, whose ECG-C lacks a prolonged QT diagnostic statement, physicians should examine the actual QTc value displayed on the report before concluding that this parameter is normal.14 They also conclude that assessment of the clinical impact of prolonged QT diagnosis suppression by ECG waveform-based criteria is warranted.14It is evident that automated evaluation of the QT interval is one of the particularly important functions of any ECG-C. Identification of a prolonged heart rate corrected QT interval (QTc) may identify an individual with an inherited LQTS at-risk for sudden cardiac death because of torsade de point.3,7–13 The QTc also serves as a marker of risk for individuals with a prolonged QT interval, acquired from electrolyte abnormalities or drugs.3,7–13 Specific technical and clinical recommendations for measurement of the QT and QTc intervals on the ECG have been made in a American Heart Association consensus document written to standardize the interpretation of ECGs.3 It is recommended that, in addition to rate, an adjustment for sex and age be incorporated into QTc measurement.3 As practical clinical limits for considering the QT interval as abnormal, this document recommends that the adjusted QT of 460 ms or longer in women and 450 ms or longer in men be considered a prolonged QT interval, and that QT of 390 ms and shorter be considered a short QT interval.3 It is recommended that linear regression functions rather than the Bazett formula be used for QT-rate correction, and that the method used for rate correction be identified in ECG analysis reports.3 It is further recommended that rate correction of the QT interval should not be attempted when RR interval variability is large, as often occurs with atrial fibrillation, or when identification of the end of the T-wave is unreliable.3 In view of the clinical importance of the QT-interval prolongation, it is essential to validate QT-interval prolongation reported by a computer algorithm visually.3 In addition to administration of QT-prolonging cardioactive drugs, a number of conditions can induce QT prolongation.3 It is often possible to identify a specific cause of QT prolongation, when appropriate clinical information is available.3 Electrolyte disturbances, including hypokalemia, hypomagnesemia, and hypocalcemia, can prolong phase 2 and phase 3 of the action potential and prolong the QT interval.3 A comprehensive and current list of all possible causes of QT prolongation is readily available.15 It is evident that presence in an ECG report of QTc prolongation should call for a careful clinical evaluation of possible causes.3The report by Lehman and colleagues placing emphasis on algorithmic suppression of abnormal QTc intervals serves to extend prior observations on the limitations of the ECG-C.14 As noted by the authors, the study was not designed to analyze physician responses or clinical outcomes related to ECG-C interpretations.14 Thus, the investigators were not able to assess either extent of physician under-recognition of prolonged QTc values or any possible adverse clinical impact resulting from algorithmic suppression of a prolonged QT diagnosis. Furthermore, the study was confined to versions of the ECG manufacturer's software.14 A more recent software update, now in the implementation phase, continues to rely on the previously utilized ECG waveform-based criteria for prolonged QT diagnosis reporting and suppression.14 However, the newer version also offers an option of automated notification of user-defined critical QTc values.14Given the profound clinical implications of the ECG-C, all clinicians must be mindful of potential for erroneous interpretation resulting in unnecessary, potentially harmful medical treatment, and inappropriate use of medical resources. The publication by Lehman serves to remind clinicians that the appropriate use of the ECG-C is as a supplement, but not a substitute, for interpretation by an electrocardiographer. Although it has been known for 3 decades that measurements made by different automated ECG-C systems from standardized reference ECG databases can vary enough to alter ECG-C diagnostic interpretation, many clinicians remain unaware of the considerable limitations of the ECG-C.16 Although ECG-C diagnostic statements continue to improve, it remains evident that over-reading and confirmation is still required of every ECG-C, when used for screening or making any clinical decisions.3DisclosuresNone.FootnotesThe opinions expressed in this article are not necessarily those of the editors or of the American Heart Association.Correspondence to N.A. Mark Estes III, MD, Professor of Medicine, Tufts University School of Medicine, 750 Washington St, Boston, MA 02111. E-mail [email protected]References1. Einthoven W. Galvanometrische registratie van het menschelijk electrocardiogram.In: Herinneringsbundel Professor., Rosenstein S. S.Leiden, Netherlands: Eduard Ijdo, 1902:101–106.Google Scholar2. Kligfield P. The centennial of the Einthoven electrocardiogram.J Electrocardiol. 2002; 35(Suppl):123–129.CrossrefMedlineGoogle Scholar3. Kligfield P, Gettes LS, Bailey JJ, Childers R, Deal BJ, Hancock EW, van Herpen G, Kors JA, Macfarlane P, Mirvis DM, Pahlm O, Rautaharju P, Wagner GS, Josephson M, Mason JW, Okin P, Surawicz B, Wellens H; American Heart Association Electrocardiography and Arrhythmias Committee, Council on Clinical Cardiology; American College of Cardiology Foundation; Heart Rhythm Society. Recommendations for the standardization and interpretation of the electrocardiogram: part I: The electrocardiogram and its technology: a scientific statement from the American Heart Association Electrocardiography and Arrhythmias Committee, Council on Clinical Cardiology; the American College of Cardiology Foundation; and the Heart Rhythm Society: endorsed by the International Society for Computerized Electrocardiology.Circulation. 2007; 115:1306–1324.LinkGoogle Scholar4. Willems JL, Abreu-Lima C, Arnaud P, van Bemmel JH, Brohet C, Degani R, Denis B, Gehring J, Graham I, van Herpen G. The diagnostic performance of computer programs for the interpretation of electrocardiograms.N Engl J Med. 1991; 325:1767–1773.CrossrefMedlineGoogle Scholar5. Shah AP, Rubin SA. Errors in the computerized electrocardiogram interpretation of cardiac rhythm.J Electrocardiol. 2007; 40:385–390.CrossrefMedlineGoogle Scholar6. Bogun F, Anh D, Kalahasty G, Wissner E, Bou Serhal C, Bazzi R, Weaver WD, Schuger C. Misdiagnosis of atrial fibrillation and its clinical consequences.Am J Med. 2004; 117:636–642.CrossrefMedlineGoogle Scholar7. Miller MD, Porter Cb , Ackerman MJ. Diagnostic accuracy of screening electrocardiograms in long QT syndrome I.Pediatrics. 2001; 108:8–12.CrossrefMedlineGoogle Scholar8. Kligfield P, Hancock EW, Helfenbein ED, Dawson EJ, Cook MA, Lindauer JM, Zhou SH, Xue J. Relation of QT interval measurements to evolving automated algorithms from different manufacturers of electrocardiographs.Am J Cardiol. 2006; 98:88–92.CrossrefMedlineGoogle Scholar9. Hnatkova K, Gang Y, Batchvarov VN, Malik M. Precision of QT interval measurement by advanced electrocardiographic equipment.Pacing Clin Electrophysiol. 2006; 29:1277–1284.CrossrefMedlineGoogle Scholar10. Salvi V, Karnad DR, Panicker GK, Natekar M, Hingorani P, Kerkar V, Ramasamy A, de Vries M, Zumbrunnen T, Kothari S, Narula D. Comparison of 5 methods of QT interval measurements on electrocardiograms from a thorough QT/QTc study: effect on assay sensitivity and categorical outliers.J Electrocardiol. 2011; 44:96–104.CrossrefMedlineGoogle Scholar11. Drew BJ, Califf RM, Funk M, Kaufman ES, Krucoff MW, Laks MM, Macfarlane PW, Sommargren C, Swiryn S, Van Hare GF; American Heart Association; Councils on Cardiovascular Nursing, Clinical Cardiology, and Cardiovascular Disease in the Young. Practice standards for electrocardiographic monitoring in hospital settings: an American Heart Association scientific statement from the Councils on Cardiovascular Nursing, Clinical Cardiology, and Cardiovascular Disease in the Young: endorsed by the International Society of Computerized Electrocardiology and the American Association of Critical-Care Nurses.Circulation. 2004; 110:2721–2746.LinkGoogle Scholar12. Drew BJ, Funk M. Practice standards for ECG monitoring in hospital settings: executive summary and guide for implementation.Crit Care Nurs Clin North Am. 2006; 18:157–168, ix.CrossrefMedlineGoogle Scholar13. Kowey PR, VanderLugt JT, Luderer JR. Safety and risk/benefit analysis of ibutilide for acute conversion of atrial fibrillation/flutter.Am J Cardiol. 1996; 78(8A):46–52.CrossrefMedlineGoogle Scholar14. Lehman MH, Garg A. A prolonged QT interval diagnosis suppression by a widely used computerized ECG analysis system.Circ Arrhythm Electrophysiol. 2013; 6.Google Scholar15. http://www.azcert.org/medical-pros/drug-lists/drug-lists.cfm. Accessed January 1, 2013.Google Scholar16. Willems JL, Arnaud P, van Bemmel JH, Bourdillon PJ, Brohet C, Dalla Volta S, Andersen JD, Degani R, Denis B, Demeester M. Assessment of the performance of electrocardiographic computer programs with the use of a reference data base.Circulation. 1985; 71:523–534.LinkGoogle Scholar Previous Back to top Next FiguresReferencesRelatedDetailsCited By Paez Perez Y, Rimm S, Bove J, Hochman S, Liu T, Catapano A, Shroff N, Lim J and Rimm B (2022) Does the Electrocardiogram Machine Interpretation Affect the Ability to Accurately Diagnose ST-Elevation Myocardial Infarction by Emergency Physicians?, Critical Pathways in Cardiology: A Journal of Evidence-Based Medicine, 10.1097/HPC.0000000000000310, 22:1, (8-12), Online publication date: 1-Mar-2023. Chua D and Brar T (2021) Erroneous Computerized Interpretation of QTc and Changes to Patient Drug Therapy: Cautionary Example for Pharmacists, Annals of Pharmacotherapy, 10.1177/10600280211049469, 56:7, (850-852), Online publication date: 1-Jul-2022. Breen C, Kelly G and Kernohan W (2022) ECG interpretation skill acquisition: A review of learning, teaching and assessment, Journal of Electrocardiology, 10.1016/j.jelectrocard.2019.03.010, 73, (125-128), Online publication date: 1-Jul-2022. Dekie L and Kleiman R (2022) False Negative ECG Device Results May Increase the Risk of Adverse Events in Clinical Oncology Trials, Therapeutic Innovation & Regulatory Science, 10.1007/s43441-022-00405-0, 56:4, (667-676), Online publication date: 1-Jul-2022. Zhao Z, Murphy D, Gifford H, Williams S, Darlington A, Relton S, Fang H and Wong D (2022) Analysis of an adaptive lead weighted ResNet for multiclass classification of 12-lead ECGs, Physiological Measurement, 10.1088/1361-6579/ac5b4a, 43:3, (034001), Online publication date: 31-Mar-2022. Chikata A, Kato T, Usuda K, Hayashi K and Takamura M (2021) Does pulmonary vein isolation prolong QT interval?, EP Europace, 10.1093/europace/euab152, 23:12, (2046-2046), Online publication date: 7-Dec-2021. Faramand Z, Helman S, Ahmad A, Martin-Gill C, Callaway C, Saba S, Gregg R, Wang J and Al-Zaiti S (2021) Performance and limitations of automated ECG interpretation statements in patients with suspected acute coronary syndrome, Journal of Electrocardiology, 10.1016/j.jelectrocard.2021.08.014, 69, (45-50), Online publication date: 1-Nov-2021. Nannavecchia A, Girardi F, Fina P, Scalera M and Dimauro G (2021) Personal Heart Health Monitoring Based on 1D Convolutional Neural Network, Journal of Imaging, 10.3390/jimaging7020026, 7:2, (26) Rjoob K, Bond R, Finlay D, McGilligan V, Leslie S, Rababah A, Iftikhar A, Guldenring D, Knoery C, McShane A and Peace A (2021) Towards Explainable Artificial Intelligence and Explanation User Interfaces to Open the 'Black Box' of Automated ECG Interpretation Advanced Visual Interfaces. Supporting Artificial Intelligence and Big Data Applications, 10.1007/978-3-030-68007-7_6, (96-108), . Gunaseelan R, Sasikumar M and Balamurugan N (2020) A Young Patient With Chest Pain, Circulation, 142:13, (1299-1301), Online publication date: 29-Sep-2020. Ribeiro A, Ribeiro M, Paixão G, Oliveira D, Gomes P, Canazart J, Ferreira M, Andersson C, Macfarlane P, Meira W, Schön T and Ribeiro A (2020) Automatic diagnosis of the 12-lead ECG using a deep neural network, Nature Communications, 10.1038/s41467-020-15432-4, 11:1 Zhang K, Aleexenko V and Jeevaratnam K (2020) Computational approaches for detection of cardiac rhythm abnormalities: Are we there yet?, Journal of Electrocardiology, 10.1016/j.jelectrocard.2019.12.009, 59, (28-34), Online publication date: 1-Mar-2020. Knoery C, Bond R, Iftikhar A, Rjoob K, McGilligan V, Peace A, Heaton J and Leslie S (2019) SPICED-ACS: Study of the potential impact of a computer-generated ECG diagnostic algorithmic certainty index in STEMI diagnosis: Towards transparent AI, Journal of Electrocardiology, 10.1016/j.jelectrocard.2019.08.006, 57, (S86-S91), Online publication date: 1-Nov-2019. Alahmadi A, Davies A, Royle J, Vigo M and Jay C (2019) Evaluating the Impact of Pseudo-Colour and Coordinate System on the Detection of Medication-induced ECG Changes CHI '19: CHI Conference on Human Factors in Computing Systems, 10.1145/3290605.3300353, 9781450359702, (1-13), Online publication date: 2-May-2019. Alahmadi A, Davies A, Vigo M and Jay C (2019) Can laypeople identify a drug-induced QT interval prolongation? A psychophysical and eye-tracking experiment examining the ability of nonexperts to interpret an ECG, Journal of the American Medical Informatics Association, 10.1093/jamia/ocy183, 26:5, (404-411), Online publication date: 1-May-2019. Smulyan H (2019) The Computerized ECG: Friend and Foe, The American Journal of Medicine, 10.1016/j.amjmed.2018.08.025, 132:2, (153-160), Online publication date: 1-Feb-2019. Heemskerk C, Pereboom M, van Stralen K, Berger F, van den Bemt P, Kuijper A, van der Hoeven R, Mantel-Teeuwisse A and Becker M (2017) Risk factors for QTc interval prolongation, European Journal of Clinical Pharmacology, 10.1007/s00228-017-2381-5, 74:2, (183-191), Online publication date: 1-Feb-2018. Cairns A, Bond R, Finlay D, Guldenring D, Badilini F, Libretti G, Peace A and Leslie S (2017) A decision support system and rule-based algorithm to augment the human interpretation of the 12-lead electrocardiogram, Journal of Electrocardiology, 10.1016/j.jelectrocard.2017.08.007, 50:6, (781-786), Online publication date: 1-Nov-2017. Breger A, Ehler M, Bogunovic H, Waldstein S, Philip A, Schmidt-Erfurth U and Gerendas B (2017) Supervised learning and dimension reduction techniques for quantification of retinal fluid in optical coherence tomography images, Eye, 10.1038/eye.2017.61, 31:8, (1212-1220), Online publication date: 1-Aug-2017. Schläpfer J and Wellens H (2017) Computer-Interpreted Electrocardiograms, Journal of the American College of Cardiology, 10.1016/j.jacc.2017.07.723, 70:9, (1183-1192), Online publication date: 1-Aug-2017. Novotny T, Bond R, Andrsova I, Koc L, Sisakova M, Finlay D, Guldenring D, Spinar J and Malik M (2017) The role of computerized diagnostic proposals in the interpretation of the 12-lead electrocardiogram by cardiology and non-cardiology fellows, International Journal of Medical Informatics, 10.1016/j.ijmedinf.2017.02.007, 101, (85-92), Online publication date: 1-May-2017. Botelho A, Oliveira M, Soto-Blanco B and Melo M (2016) Computerized electrocardiography in healthy conscious guinea pigs (Cavia porcellus), Pesquisa Veterinária Brasileira, 10.1590/s0100-736x2016001200011, 36:12, (1203-1208), Online publication date: 1-Dec-2016. Kleiman R, Litwin J and Morganroth J (2016) Benefits of Centralized ECG Reading in Clinical Oncology Studies, Therapeutic Innovation & Regulatory Science, 10.1177/2168479015597729, 50:1, (123-129), Online publication date: 1-Jan-2016. Aurora R, Swartz R and Punjabi N (2015) Misclassification of OSA Severity With Automated Scoring of Home Sleep Recordings, Chest, 10.1378/chest.14-0929, 147:3, (719-727), Online publication date: 1-Mar-2015. Fent G, Gosai J and Purva M (2015) Teaching the interpretation of electrocardiograms: Which method is best?, Journal of Electrocardiology, 10.1016/j.jelectrocard.2014.12.014, 48:2, (190-193), Online publication date: 1-Mar-2015. Kvittingen E, Gjelsvik B and Gjesdal K EKG i allmennpraksis – kvaliteten kan forbedres, Tidsskrift for Den norske legeforening, 10.4045/tidsskr.15.0310, 135:8, (746-746) February 2013Vol 6, Issue 1 Advertisement Article InformationMetrics © 2013 American Heart Association, Inc.https://doi.org/10.1161/CIRCEP.111.000097PMID: 23424219 Originally publishedFebruary 1, 2013 KeywordsEditorialsECGPDF download Advertisement SubjectsElectrocardiology (ECG)

Referência(s)