Artigo Acesso aberto Revisado por pares

The Ventilation Effect on Stator Convective Heat Transfer of an Axial-Flux Permanent-Magnet Machine

2013; Institute of Electrical and Electronics Engineers; Volume: 61; Issue: 8 Linguagem: Inglês

10.1109/tie.2013.2284151

ISSN

1557-9948

Autores

Yew Chuan Chong, Estanislao J. P. Echenique Subiabre, Markus Mueller, John Chick, D.A. Staton, Alasdair McDonald,

Tópico(s)

Magnetic Properties and Applications

Resumo

This paper investigates the effect of the inlet configuration on cooling for an air-cooled axial-flux permanent-magnet (AFPM) machine. Temperature rises in the stator were measured and compared with results predicted using computational fluid dynamic (CFD) methods linked to a detailed machine loss characterization. It is found that an improved inlet design can significantly reduce the stator temperature rises. Comparison between the validated CFD model results and the values obtained from heat transfer correlations addresses the suitability of those correlations proposed specifically for AFPM machines.

Referência(s)