Revisão Acesso aberto Revisado por pares

The modern office environment desiccates the eyes?

2006; Wiley; Volume: 16; Issue: 4 Linguagem: Inglês

10.1111/j.1600-0668.2006.00429.x

ISSN

1600-0668

Autores

Peder Wolkoff, Jacob Klenø Nøjgaard, Carsten Franck, Peder Skov,

Tópico(s)

Safety Warnings and Signage

Resumo

Indoor AirVolume 16, Issue 4 p. 258-265 The modern office environment desiccates the eyes? P. Wolkoff, P. Wolkoff Indoor Environment Group, National Institute of Occupational Health, Copenhagen, DenmarkSearch for more papers by this authorJ. K. Nøjgaard, J. K. Nøjgaard Indoor Environment Group, National Institute of Occupational Health, Copenhagen, DenmarkSearch for more papers by this authorC. Franck, C. Franck Department of Occupational Medicine, Slagelse County Hospital, Slagelse, DenmarkSearch for more papers by this authorP. Skov, P. Skov Department of Occupational Medicine, Roskilde County Hospital, Køge, DenmarkSearch for more papers by this author P. Wolkoff, P. Wolkoff Indoor Environment Group, National Institute of Occupational Health, Copenhagen, DenmarkSearch for more papers by this authorJ. K. Nøjgaard, J. K. Nøjgaard Indoor Environment Group, National Institute of Occupational Health, Copenhagen, DenmarkSearch for more papers by this authorC. Franck, C. Franck Department of Occupational Medicine, Slagelse County Hospital, Slagelse, DenmarkSearch for more papers by this authorP. Skov, P. Skov Department of Occupational Medicine, Roskilde County Hospital, Køge, DenmarkSearch for more papers by this author First published: 31 May 2006 https://doi.org/10.1111/j.1600-0668.2006.00429.xCitations: 57 Peder WolkoffIndoor Environment GroupNational Institute of Occupational HealthDenmarkTel.: +45 39 16 52 72Fax: +45 39 16 52 01e-mail: [email protected] Read the full textAboutPDF ToolsRequest permissionExport citationAdd to favoritesTrack citation ShareShare Give accessShare full text accessShare full-text accessPlease review our Terms and Conditions of Use and check box below to share full-text version of article.I have read and accept the Wiley Online Library Terms and Conditions of UseShareable LinkUse the link below to share a full-text version of this article with your friends and colleagues. Learn more.Copy URL Share a linkShare onEmailFacebookTwitterLinkedInRedditWechat References Balci, R. and Aghazader, F. (2003) The effect of work-rest schedules and type of task on the discomfort and performance of VDT users, Ergonomics, 46, 455–465. Blehm, C., Vishnu, S., Khattak, A., Mitra, S. and Yee, R.W. (2005) Computer vision syndrome: a review, Surv. Ophthalmol., 50, 253–262. Bluyssen, P.M., De Olivera Fernandes, E., Groes, L., Clausen, G., Fanger, P.O., Valbjørn, O., Bernhard, C.A. and Roulet, C.A. (1996) European indoor air quality audit project in 56 office buildings, Indoor Air, 6, 221–238. Brasche, S., Bullinger, M., Bronish, M. and Bischof, W. (2001) Eye- and skin symptoms in German office workers - subjective perception vs. objective medical screening, Int. J. Hyg. Environ. Health, 203, 311–316. Brasche, S., Bullinger, M., Petrovitch, A., Mayer, E., Gebhardt, H., Herzog, V. and Bischof, W. (2005) Self-reported eye symptoms and related diagnostic findings – comparison of risk factor profiles, Indoor Air, 15, 56–64. Brauer, C. and Mikkelsen, S. (2003) The context of a study influences the reporting of symptoms, Int. Arch. Occup. Environ. Health, 76, 621–624. Brightman, H.S. and Moss, N. (2000) Sick building syndrome studies and the compilation of normative and comparative values. In: J.D. Spengler, J.M. Samet and J.F. McCarthy (eds) Indoor Air Quality Handbook, New York, McGraw-Hill, 3.1–3.32. Bron, A.J., Tiffany, J.M., Gouveia, S.M., Yokoi, N. and Voon, L.W. (2004) Functional aspects of the tear film lipid layer, Exp. Eye Res., 78, 347–360. Chao, H.J., Schwartz, J., Milton, D.K. and Burge, H.A. (2003) The work environment and workers' health in four large office buildings, Environ. Health Perspec., 111, 1242–1248. Collins, M., Seeto, R., Campbell, L. and Ross, M. (1989) Blinking and corneal sensitivity, Acta Ophthalmol., 67, 525–531. Craig, J.P. (2002) Structure and function of the preocular tear film. In: The Tear Film: Structure, Function and Clinical Examination, Oxford, Butterworth-Heinemann, 18–50. Craig, J.P. and Tomlinson, A. (1997) Importance if the lipid layer in human tear film stability and evaporation, Optom. Vis. Sci., 74, 8–13. Di Pasquale, M.A., Goto, E. and Tseng, S.C.G. (2004) Sequential changes of lipid tear film after installation of a single drop of a new emulsion eye drop in dry eye patients, Ophthalmology, 111, 783–791. Doty, R.L., Cometto-Muñiz, J.E., Jalowayski, A.A., Dalton, P., Kendall-Reed, M. and Hodgson, M. (2004) Assessment of upper respiratory tract and ocular irritative effects of volatile chemicals in humans, Crit. Rev. Toxicol., 34, 85–142. Doughty, M.J., Blades, K.A. and Ibrahim, N. (2002) Assessment of the number of eye symptoms and the impact of some confounding variables for office staff in non-air-conditioned buildings, Opthal. Physiol. Opt., 22, 143–155. Efron, N., Young, G. and Brennan, N.A. (1989) Ocular surface temperature, Curr. Eye Res., 8, 901–906. Fang, L., Wyon, D.P., Clausen, G. and Fanger, P.O. (2004) Impact of indoor air temperature and humidity in an office on perceived air quality, SBS symptoms and performance, Indoor Air, 14, 74–81. Farris, R.L. (1997) The diagnosis and management of the dry eye, J. Ophthal. Nursing. Technol., 16, 164–174. Franck, C. (1986) Eye Symptoms and signs in buildings with indoor climate problems ('Office Eye Syndrome'), Acta Ophthalmol., 64, 306–311. Franck, C. and Skov, P. (1989) Foam at inner eye canthus in office workers, compared with an average Danish population as control group, Acta Ophthalmol., 67, 61–68. Franck, C., Bach, E. and Skov, P. (1993) Prevalence of objective eye manifestations in people working in office buildings with different prevalences of the sick building syndrome compared with the general population, Int. Arch. Occup. Environ. Health, 65, 65–69. Galinsky, T.L., Swanson, N.G., Sauter, S.L., Hurrell, J.J. and Schleifer, M. (2000) A field study of supplementary rest breaks for data-entry operators, Ergonomics, 43, 622–638. Gilbard, J.P. (1999) Dry eye, blepharitis and chronic eye irritation: divide and conquer, J. Ophthamol. Nursing Technol., 18, 109–115. Groes, L., Pejtersen, J. and Valbjørn, O. (1996) Perception and symptoms as a function of indoor environmental factors, personal factors and building characteristics in office buildings. In: Proceedings of Indoor Air '96, Vol. 4, 237–242, Indoor Air '96, Tokyo. Hedge, A. and Evans, S.J. (2001) Ergonomic Management Software and Work Performance. Cornell University Human Factors Laboratory Technical Report/RP2501. Ithaca, NY, Cornell University. Hedge, A., Erickson, A. and Rubin, G. (1996) Predicting sick building syndrome at the individual and aggregate levels, Environ. Int., 22, 3–19. Henning, R.A., Jacques, P., Kissel, G.V., Sullivan, A.B. and Alteras-Webb, S.M. (1997) Frequent short rest breaks from computer work: effects on productivity and well-being at two field sites, Ergonomics, 40, 78–91. Höppe, P., Praml, G., Rabe, G., Lindner, J., Fruhmann, G. and Kessel, R. (1995) Environmental ozone field study on pulmonary and subjective responses of assumed risk groups, Environ. Res., 71, 109–121. Kay, D.L.C., Heavner, D.L., Nelson, P.R., Jennings, R.A., Eaker, D.W., Robinson, J.H., DeLuca, P.O., Risner, C.H. and Brockschmidt, J.K. (1990) Effects of relative humidity on nonsmoker response to environmental tobacco smoke. In: Proceedings of Indoor Air '90, Vol. 1, 275–280, Canada Mortgage and Housing Corporation, Ottawa, Ontario. King-Smith, P.E., Fink, B.A., Hill, R.M., Koelling, K.W. and Tiffany, J.M. (2004) The thickness of the tear film, Cur. Eye Res., 29, 357–368. Kjærgaard, S.K. (2000) The irritated eye in indoor environment. In: J.D. Spengler, J.M. Samet and J.F. McCarthy (eds) Indoor Air Quality Handbook, New York, McGraw-Hill, 17.1–17.15. Kjærgaard, S.K. and Brandt, J. (1993) Objective human conjunctival reactions to dust exposure, VDT-work and temperature in sick buildings. In: Proceedings of Indoor Air '93, Vol. 1, 41–46, Indoor Air '93, Helsinki. Kjærgaard, S.K., Hempel-Jørgensen, A., Mølhave, L., Andersson, K., Juto, J.E. and Stridh, G. (2004) Eye trigeminal sensitivity, tear film stability, and conjunctival epithelium damage in 182 non-allergic, non-smoking Danes, Indoor Air, 14, 200–207. Korb, D.R. (2002) The tear film – its role today and in the future. In: The Tear Film – Structure, Function and Clinical Examination, Oxford, Butterworth Heinemann, 126–192. Korb, D.R., Greiner, J.V., Glonek, T., Esbah, R., Finnemore, V.M. and Whalen, A.C. (1996) Effect of periocular humidity on the tear film lipid layer, Cornea, 15, 129–134, Tsinghua University Press, Beijing. Korb, D.R., Scaffidi, R.C., Greiner, J.V., Kenyon, K.R., Herman, J.P., Blackie, C.A., Glonek, T., Case, C.L., Finnemore, V.M. and Douglass, T. (2005) The effect of two novel lubricant eye drops on tear film lipid layer thickness in subjects with dry eye symptoms, Optom. Vis. Sci., 82, 594–601. Lee, S., Dausch, S., Maierhofer, G. and Dausch, D. (2004) Ein neues Therapiekonzept zur behandlung des trockenen Auges – die Verwendung von Phospholipid-Liposomen, Klin. Monatsbl. Augenheilkd., 221, 825–836. Lemp, M.A. (1995) Report of the National Eye Institute/Industry Workshop on Clinical Trials in Dry Eyes, CLAO J., 21, 221–232. Lozato, P.A., Pisella, P.J. and Baudoin, C. (2001) The lipid layer of the lacrimal tear film: physiology and pathology, J. Fr. Ophthalmol., 24, 643–658. Mendell, M.J. (2004) Commentary: air conditioning as a risk for increased use of health services, Int. J. Epidemiol., 33, 1123–1126. Mendell, M.J., Fisk, W.J., Dong, M.X., Petersen, M., Hines, C.J., Dong, M., Faulkner, D., Deddens, J.A., Ruder, A.M., Sullivan, D.A. and Boeniger, M.F. (2002) Indoor particles and symptoms among office workers: results from a double-blind cross-over study, Epidemiology, 13, 296–304. Murakami, S. (2004) Analysis and design of micro-climate around the human body with respiration by CFD, Indoor Air, 14(7), 144–156. Murphy, P.J., Patel, S., Morgan, P.B. and Marshall, J. (2001) The minimum stimulus energy required to produce a cooling sensation in the human cornea, Opthal. Physiol. Opt., 21, 407–410. Nøjgaard, J.K., Christensen, K.B. and Wolkoff, P. (2005) The effect on human eye blink frequency by exposure to limonene oxidation products and methacrolein, Toxicol. Lett., 156, 241–251. Nagda, N.L. and Hodgson, M. (2001) Low relative humidity and air cabin air quality, Indoor Air, 11, 200–214. Nakamori, K., Odawara, M., Nakajima, K., Mizutani, T. and Tsubota, K. (1997) Blinking is controlled primarily by ocular surface conditions, Am. J. Ophthalmol., 124, 24–30. Nichols, K.K., Begley, C.G., Caffery, B. and Jones, L.A. (1999) Symptoms of ocular irritation in patients diagnosed with dry eye, Optom. Vis. Sci., 76, 838–844. Nielsen, P.K., Sjøgaard, G., Bengtsen, E. and Wolkoff, P. (2005) The influence of major factors on eye irritation related symptoms during PC work – a literature review. In: Proceedings of Indoor Air '05, Vol. 5, 3782–3786. Norbäck, D., Wieslander, G., Nordström, K., Wålinder, R. and Venge, P. (2000) The effect of air humidification on symptoms and nasal patency, tear film stability, and biomarkers in nasal lavage: a 6 weeks' longitudinal study, Indoor + Built Environ., 9, 28–34. Norn, M.S. (1992) Pollution keratoconjunctivitis, Acta Ophthalmol., 70, 269–273. Paschides, C.A., Stefaniotou, M., Papageorgiou, J., Skourtis, P. and Psilas, K. (1998) Ocular surface and environmental changes, Acta Ophthalmol. Scand., 76, 74–77. Pejtersen, J. and Allerman, L. (2004) Indeklima, psykosocialt arbejdsmiljø og støvs potentiale, København, Arbejdsmiljøinstituttet. Prause, J.U. and Norn, M.S. (1987) Relation between blink frequency and break-up time, Acta Ophthalmol., 65, 19–22. Rocher, P. and Fatt, I. (1995) Hydrogel Contact Lenses, Optometry Today, 35 (July), 18–22. Satici, A., Bitiren, M., Ozardali, I., Vural, H., Kilic, A. and Guzey, M. (2003) The effects of chronic smoking on the ocular surface and tear characteristics: a clinical, histological and biochemical study, Acta Ophthalmol. Scand., 81, 583–587. Sato, M., Fukayo, S. and Yano, E. (2003) Adverse environmental health effects of ultra-low relative humidity indoor air, J. Occup. Health, 45, 133–136. Saxena, R., Srivastava, S., Trivedi, D., Anand, E., Joshi, S. and Gupta, S.K. (2003) Impact of environmental pollution on the eye, Acta Ophthalmol. Scand., 81, 491–494. Skov, P., Valbjørn, O., Pedersen, B.V. and DISG (1989) Influence of personal characteristics, job-related factors and psychosocial factors on the sick building syndrome, Scand. J. Work Environ. Health, 15, 286–297. Smedbold, H.T., Ahlen, C., Norbäck, D. and Hilt, B. (2001) Sign of eye irritation in female hospital workers and the indoor environment, Indoor Air, 11, 223–231. Subramanian, P., Reynolds, S., Breuer, G. and Whitten, P. (2000) Analysis of limonene as an indicator for the assessment of environmental air-quality and health symptoms in office buildings, J. Environ. Sci. Health, A: Toxic/Hazard. Subst. Environ. Eng., A35, 999–1019. Sundell, J. and Lindvall, T. (1993) Indoor air humidity and the sensation of dryness as risk indicators of SBS, Indoor Air, 3, 382–390. Sundell, J., Andersson, B., Andersson, K. and Lindvall, T. (1993) Volatile organic compounds in ventilating air in buildings at different sampling points in the buildings and their relationship with the prevalence of occupant symptoms, Indoor Air, 3, 82–93. Tamblyn, R.M., Menzies, R.I., Tamblyn, R.T., Farant, J.-P. and Hanley, J. (1992) The feasibility of using a double blind experimental cross-over design to study interventions for sick building syndrome, J. Clin. Epidemiol., 45, 603–612. Toda, I., Fujishima, H. and Tsubota, K. (1993) Ocular fatigue is the major symptom of dry eye, Acta Ophthalmol., 71, 347–352. Toda, I., Shimazaki, J. and Tsubota, K. (1995) Dry eye with only decreased tear break-up time is sometimes associated with allergic conjunctivitis, Ophthalmology, 102, 302–309. Tsubota, K. (2002) Understanding dry eye syndrome. In: D. Sullivan, A.H. Stern, K. Tsubota, D.A. Dartt, R.M. Sullivan and B.B. Bromberg (eds) Lacrimal Gland, Tear Film, and Dry Eye Syndrome 3, New York, Kluwer Academic/Plenum Publishers, 3–16. Tsubota, K., Hata, S., Okusawa, Y., Egami, F., Ohtsuki, T. and Nakamori, K. (1996) Quantative videographic analysis of blinking in normal subjects and patients with dry eye, Arch. Ophthalmol., 114, 715–720. Tsubota, K., Hata, S., Mori, A., Nakamori, K. and Fujishima, H. (1997) Decreased blinking in dry saunas, Cornea, 16, 242–244. Versura, P. and Campos, E.C. (2005) Menopause and dry eye. A possible relationship, Gynecol. Endocrin., 20, 289–298. Versura, P., Profazio, V., Cellini, M., Torreggiani, A. and Caramazza, R. (1999) Eye discomfort and air pollution, Ophthalmologica, 213, 103–109. Wieslander, G., Lindgren, T., Norbäck, D. and Venge, P. (2000) Changes in the ocular and nasal signs and symptoms of aircrew in relation to the ban on smoking on intercontinental flights, Scand. J. Work Environ. Health, 26, 514–522. Wilkins, C.K., Wolkoff, P., Clausen, P.A., Hammer, M. and Nielsen, G.D. (2003) Upper airway irritation of terpene/ozone oxidation products (TOPS). Dependence on reaction time, relative humidity and initial ozone concentration, Toxicol. Lett., 143, 109–114. Wolkoff, P., Nielsen, G.D., Hansen, L.F., Albrechtsen, O., Johnsen, C.R., Heinig, J.H. and Franck, C. (1991) A study of human reactions to building materials in climatic chambers. Part II: VOC measurements, mouse bioassay, and decipol evaluation in the 1–2 mg/m3 TVOC range, Indoor Air, 1, 389–403. Wolkoff, P., Johnsen, C.R., Franck, C., Wilhardt, P. and Albrechtsen, O. (1992) A study of human reactions to office machines in a climatic chamber, J. Exp. Anal. Environ. Epidemiol., 1(Suppl.), 71–97. Wolkoff, P., Skov, P., Franck, C. and Pedersen, L.N. (2003) Eye irritation and environmental factors in the office environment. Hypotheses, causes, and a physiological model, Scand. J. Work Environ. Health, 29, 411–430. Wolkoff, P., Nøjgaard, J.K., Troiano, P. and Piccoli, B. (2005) Eye complaints in the office environment: precorneal tear film integrity influenced by eye blinking efficiency, Occup. Environ. Med., 62, 4–12. Wolkoff, P., Wilkins, C.K., Clausen, P.A. and Nielsen, G.D. (2006) Organic compounds in office environments – sensory irritation, odor, measurements, and the role of reactive chemistry, Indoor Air, 16, 7–19. Yamada, F. (1998) Frontal midline theta rhythm and eyeblinking activity during a VDT task and a video game: useful tools for psychophysiology in ergonomics, Ergonomics, 41, 678–688. Yap, M. (1991) Tear break-up is related to blink frequency, Acta Ophthalmol., 69, 92–94. Citing Literature Volume16, Issue4August 2006Pages 258-265 ReferencesRelatedInformation

Referência(s)
Altmetric
PlumX