Artigo Revisado por pares

60-Hz Interference in Electrocardiography

1973; Institute of Electrical and Electronics Engineers; Volume: BME-20; Issue: 2 Linguagem: Inglês

10.1109/tbme.1973.324169

ISSN

1558-2531

Autores

James C. Huhta, John G. Webster,

Tópico(s)

ECG Monitoring and Analysis

Resumo

One of the major problems encountered in recording ECG's is the appearance of unwanted 60-Hz interference in the output. This paper examines the many possible sources of interference, and for each provides a description, an identifying test, and a remedy. Then we look at possible equipment imperfections and guidelines for amplifier design to aid in the evaluation of new developments in the field of electrocardiography. As an illustrative example, we apply the procedure for isolating the source of interference to an exposition display in which each visitor could rapidly view his own ECG.

Referência(s)