Artigo Acesso aberto Revisado por pares

Hybrid operation strategy of wind energy storage system for power grid frequency regulation

2015; Institution of Engineering and Technology; Volume: 10; Issue: 3 Linguagem: Inglês

10.1049/iet-gtd.2015.0149

ISSN

1751-8695

Autores

Jin Woo Choi, Shin Young Heo, Mun-Kyeom Kim,

Tópico(s)

Microgrid Control and Optimization

Resumo

IET Generation, Transmission & DistributionVolume 10, Issue 3 p. 736-749 ArticleOpen Access Hybrid operation strategy of wind energy storage system for power grid frequency regulation Jin Woo Choi, Jin Woo Choi Department of Energy System Engineering, Chung-Ang University, 84 Heukseok-Ro, Dongjak-gu, Seoul, 604–714 Republic of KoreaSearch for more papers by this authorShin Young Heo, Shin Young Heo Department of Energy System Engineering, Chung-Ang University, 84 Heukseok-Ro, Dongjak-gu, Seoul, 604–714 Republic of KoreaSearch for more papers by this authorMun Kyeom Kim, Corresponding Author Mun Kyeom Kim mkim@cau.ac.kr Department of Energy System Engineering, Chung-Ang University, 84 Heukseok-Ro, Dongjak-gu, Seoul, 604–714 Republic of KoreaSearch for more papers by this author Jin Woo Choi, Jin Woo Choi Department of Energy System Engineering, Chung-Ang University, 84 Heukseok-Ro, Dongjak-gu, Seoul, 604–714 Republic of KoreaSearch for more papers by this authorShin Young Heo, Shin Young Heo Department of Energy System Engineering, Chung-Ang University, 84 Heukseok-Ro, Dongjak-gu, Seoul, 604–714 Republic of KoreaSearch for more papers by this authorMun Kyeom Kim, Corresponding Author Mun Kyeom Kim mkim@cau.ac.kr Department of Energy System Engineering, Chung-Ang University, 84 Heukseok-Ro, Dongjak-gu, Seoul, 604–714 Republic of KoreaSearch for more papers by this author First published: 01 February 2016 https://doi.org/10.1049/iet-gtd.2015.0149Citations: 51AboutSectionsPDF ToolsRequest permissionExport citationAdd to favoritesTrack citation ShareShare Give accessShare full text accessShare full-text accessPlease review our Terms and Conditions of Use and check box below to share full-text version of article.I have read and accept the Wiley Online Library Terms and Conditions of UseShareable LinkUse the link below to share a full-text version of this article with your friends and colleagues. Learn more.Copy URL Share a linkShare onFacebookTwitterLinkedInRedditWechat Abstract This study presents a novel hybrid operation strategy for a wind energy conversion system (WECS) with a battery energy storage system (BESS). The proposed strategy is applied to support frequency regulation using coordinated control of WECS and BESS operations in power system. The coordinated control of the WECS consists of active power control and frequency support control based on permanent magnet synchronous generators for variable wind speed conditions. Active power control is achieved using maximum power point tracking and deloaded operation to ensure a certain power margin. In addition to this comprehensive control of the active power, frequency support control based on kinetic energy discharge control is developed to regulate the short-term frequency response and to ensure reliable operation of the power system. Concurrently, the output power command of the BESS is determined according to the state of charge and frequency deviations. The effectiveness of the hybrid operation strategy is verified by a numerical simulation in power system computer aided design/electro-magnetic transient direct current (PSCAD/EMTDC), and the results show that the proposed approach can improve the frequency regulation capability of the power system. 1 Introduction Wind energy is one of the most rapidly growing renewable power sources worldwide, and wind power penetration of the power grid has been increasing [1]. In modern wind power systems, two of the most promising types of wind turbine generators are the doubly fed induction generator (DFIG) and the permanent magnet synchronous generator (PMSG). The mechanical connection between the wind turbine and the generator shaft in the DFIG is a gearbox, which provides an extensive range of rated speed [2], whereas a PMSG is connected directly to the wind turbine without a gearbox, offering low-speed operation that does not require any external excitation current. The PMSG is much less sensitive to parameter variations and exhibits better controllability than the DFIG [3, 4]. Since power systems are dynamic, the prevalence of large-scale wind energy conversion systems (WECSs) has motivated research on frequency control, which is necessary for reliable power system operation. Most variable-speed wind turbines generally have no inherent inertial response. The wind turbine has been decoupled from the power system by electronic converters because of the impacts of output stability and frequency variability on the power system. The wind turbines always operate under maximum power point tracking (MPPT) conditions without any power reserves; thus, they cannot supply any spinning reserve in response to frequency disturbances [5]. Accordingly, system operators request that wind turbines provide an ancillary service to enhance the frequency support capability using frequency control and active/reactive power control. To maintain the stability and reliability of a power system connected to a WECS, adequate frequency control research is required to determine a method for providing additional reserve. Many researchers have studied the ability of frequency regulation in wind turbine generation to supply additional reserve. For example, frequency regulation can be implemented by inertial control, which is a means of releasing energy from the rotating mass [6–8]. The authors of [6] attempted to use an inertia contributing loop to enhance the inertia support from the wind turbine. In particular, the use of machine inertia to implement frequency control for DFIG wind turbines was described [7], whereas the authors of [8] proposed to let a variable-speed wind turbine emulate inertia and support primary frequency control. However, because inertial control uses not the power margin but the stored kinetic energy (KE) in the rotor and blade of the wind turbine, it would decrease the power output necessary to recover the initial rotational speed during system frequency regulation. In [9], the moving-average method with K-deviation was introduced to preserve a certain amount of wind power reserve. In another literature survey [10], a deloaded (DL) control was also presented as a key solution to supply a primary frequency regulation capability within very short time spans in system containing wind turbines. In [11], Keung et al. proposed the KE discharge control in which a wind farm to actively provide primary reserve to support a frequency disturbance using the stored KE in a rotor. However, if the energy regain during acceleration is not controlled properly, it may cause another frequency disturbance. Therefore, it is necessary to optimise to the frequency control strategy to effectively use the stored KE. Nowadays, an energy storage system (ESS) has been integrated with renewable sources that are connected to the power grid to maintain safe operation of the grid and to balance supply and demand. The ESS can meet the requirement for increasing the reserves to manage the uncertainty of wind generation. This can increase the system operation efficiency, enhance power absorption, and reduce carbon dioxide emissions. Among ESSs, the battery ESS (BESS) is one of the most rapidly growing storage technologies. The use of BESSs has focused attention on the reduction of adverse effects involving frequency deviations [12]. Moreover, combining a BESS with a WECS will improve the system availability and increase the amount of wind power that can penetrate the power grid without endangering system reliability. Previous work has explored the application of a BESS within a WECS for frequency support in a power system. In [13], Howlader et al. presented a minimal-order-observer-based frequency control approach for integrated small power system; in this approach, a strategy for coordinating a wind turbine generator and a BESS is applied. In [14], Khalid and Savkin proposed a method that solves a frequency control problem to obtain efficient operation of a BESS using a predictive model. In [15], Serban et al. analysed the BESS to enhance the short-term frequency stability of autonomous microgrids that include both classical- and renewable-energy-source-based generators. In [16], Virulkar and Aware presented a control methodology for battery charging under constant current-constant voltage mode topology to regulate the active and reactive energy flows in a distributed power system network. In [17], Dali et al. performed a theoretical study, experimental test, and assessment of operation of a grid-connected hybrid photovoltaic (PV)–wind system that used a standalone inverter capable of working in grid-connection mode, but also in standalone mode as a micro-grid generator. In [18], the size of a PV–wind integrated hybrid energy system with battery storage was optimised under various loads and unit costs of auxiliary energy sources. However, most of this research focuses on a BESS control strategy for frequency regulation. Additional research is needed to improve the efficiency of these methods, which is still inadequate for practical applications. Furthermore, this research does not take into account the active power reserved by coordinated regulation of either rotor speed or active power control in WECS, which contributes to frequency support control. Only a few papers address operational approaches that include a frequency control strategy for a WECS with respect to the storage capability of a BESS. In this respect, to improve the frequency response in the power system, it is necessary to develop a new strategy for WECS and BESS operations. When system operators request that a wind ESS participates in frequency regulation, this improved operation strategy will provide information that enables more secure system operation and improves the frequency response compared with that of the previous approach. This paper proposes a hybrid operation strategy for WECS and BESS operations in a power system. The proposed approach implements frequency control of the power system by coordinated control of WECS and BESS operations. Coordinated control of the WECS is applied using active power and frequency support control. A machine-side converter (MSC) and grid-side converter (GSC) are developed to achieve maximum power extraction, control the DC-link voltage and reactive power, and provide grid voltage support using standard vector control. The active power control attempts not only to operate at the MPPT for various wind speeds, but also to obtain the power margin to control DL operation. Next, frequency support control based on KE discharge control attempts to create frequency support capability for maintaining a stable wind turbine system. In addition to this coordinated control, the output power command of the BESS is determined according to the state of charge (SOC), frequency deviations, and load variation in the power system. The remainder of this paper is organised as follows. Section 2 describes the configuration of a WECS with a BESS. Section 3 presents the hybrid operation strategy for coordinated control of WECS and BESS operations. Section 4 represents our simulation results. Concluding remarks are given in Section 5. 2 PMSG wind turbine with BESS 2.1 Wind energy conversion system The WECS consists of a wind turbine, a PMSG, a MSC, and a GSC with an intermediate DC voltage link. The system converts the KE of the wind to mechanical energy through the wind turbine's rotor blades. The generator converts the mechanical power to electrical power [5]. The electrical power is fed to an electrical network through back-to-back converters. 2.1.1 Wind turbine characteristics The maximum power extracted by a variable wind turbine from the wind is expressed as [1] (1)where ρ is the air density (=1.225 kg/m2), R is the rotator radius, V is the wind speed, λopt is the optimal tip speed ratio (TSR), β is the pitch angle, and is the optimal power coefficient, which is a function of the TSR and the pitch angle. When the pitch angle β is set as zero during the MPPT operation, the optimal power coefficient is given by Lin and Hong [19] (2) (3)The optimal TSR of the mechanical output is defined as (4)where ωm,opt is the optimal mechanical rotational speed [radians/seconds (rad/s)] for a given wind speed [metres/seconds (m/s)]. From (1) and (4), the maximum power value Pmax can be obtained as a function of the shaft speed (5) (6)where Kopt is the coefficient of rotational speed for the maximum power through at the wind generator. 2.1.2 PMSG modelling The mathematical model of a PMSG in the d–q reference frame is traditionally defined as [4] (7) (8)where Vds and Vqs are the stator voltages on the d and q axes, respectively; Ls and Rs represent the inductance and the resistance of the PMSG winding, respectively; Ψf is the magnetic flux; Ids and Iqs are the direct and quadrature components of the stator currents, respectively; and ωe represents the electrical rotational speed. The electromagnetic torque Te is given by Chinchilla et al. [3] and Tan and Islam [20] (9)where Ld and Lq are the machine inductances on the d and q axes, respectively, and pn is the number of pole pairs. In surface-mounted PMSGs, Ld = Lq = Ls; therefore, the electromagnetic torque is expressed as (10)The electrical angular speed ωe and the mechanical angular speed of the generator rotor ωm are related as [21] (11) 2.1.3 Converter control To achieve optimum power efficiency despite wind speed variations, the MSC is used to control the wind turbine shaft speed [22]. Control of the MSC allows the generator to regulate the rotational speed according to the wind variation. To understand the control concept, the dynamic equation of the wind turbine is given as [23] (12)where B is the friction coefficient of the generator, J is the moment of inertia (kg/m2), and Tm is the mechanical torque. The mechanical rotational speed of the PMSG rotor is given by (13)where ωt is the rotational speed of the turbine and Gr is the gear ratio. Among existing wind generators, for gearless, PMSG-based wind turbines, Gr = 1. Fig. 1 shows the controller loop of the MSC which contains two cascaded loops. In the inner loop, current controllers regulate the d–q-axis stator current to follow a reference, whereas a speed controller in the outer loop regulates the wind turbine speed such that it follows the reference value ωm,ref and produces the q-axis current reference Iqs,ref. The stator current components cannot be controlled independently by the stator voltage components because of cross-coupling effects. These effects can be cancelled using the feed-forward compensation. The stator voltage components are decided by proportional–integral (PI) controllers and feed-forward compensation. Additionally, the d-axis reference current Ids,ref is set to zero to minimise the current and resistive losses for the given torque [3]. Then, we use pulse-width modulation to produce a switching signal for MSC control. Fig. 1Open in figure viewerPowerPoint MSC controller loop The GSC is normally controlled to achieve the following goals: (i) to maintain the reactive power exchange to the grid, which guarantees a desirable power factor or voltage during PMSG operation and (ii) to maintain the DC-link capacitor voltage at a set value, which ensures active power exchange from the PMSG to the grid [24]. Fig. 2 shows the controller loop of the GSC. The GSC consists of a power converter with two closed loops. The inner loops regulate the grid currents, whereas the outer loops control the DC voltage and reactive power delivered to the power system. The GSC control loops on the d–q-axis include a rotating reference frame and signal PI controllers. The active power reference Pref is used to maintain a constant output voltage and Qref is determined by the power factor. Using a phase-locked loop, the three-phase current is converted to the d–q frame. Fig. 2Open in figure viewerPowerPoint GSC controller loop The dynamic model voltage equations of the grid connection in the d–q reference frame rotating synchronously are represented as follows [23] (14) (15)where Vdg and Vqg are the grid voltage components in the d–q frame; Lg and Rg are the grid inductance and resistance, respectively; ωg is the angular speed of the grid; Vcd and Vcq are the converter voltage components; and Idg and Iqg are the d-axis current and q-axis current of the electric grid, respectively. The grid-side active and reactive powers can be expressed as follows (16) (17)Equations (16) and (17) show that the active and reactive powers are regulated to achieve the desired voltage by adjusting the respective current of the d–q-axis. To transfer all of the active power generated in the wind turbine, the DC-link voltage Vdc should be maintained at a constant value using the current control of the d-axis. The DC-link controller can be expressed as the following constraint (18)where C is the capacitance of the DC-link capacitor and Pt and Pg are the power of the wind turbine and the grid, respectively. The DC-link controller controls the DC-link voltage by the DC voltage reference Vdc,ref, as shown in Fig. 3. The measured error in the DC-link voltage is used to determine the generator power set-point via the PI controller. The voltage is maintained at a constant value by adjusting the reactive power. To improve the efficiency of operation for WECS, this control strategy is changed to operate with fixed unit power factor. Fig. 3Open in figure viewerPowerPoint DC-link controller loop 2.2 Battery energy storage system Among ESSs, the BESS has recently emerged as one of the most rapidly growing technologies for short-term energy storage owing to its advantages, which include cost efficiency and flexibility [25]. The aggregated BESS in a wind farm based on PMSGs is used to study the proposed strategy. The combined BESS and WECS can regulate the frequency by supplying an additional energy as well as the electric power delivered to the electrical network. 2.2.1 Aggregated BESS With the flexible charging/discharging characteristics, BESS is considered as effective device to improve controllability not only of a wind farm, but also of the entire power system. The control and operation strategy of the BESS could be designed for different application purpose. Several aspects must be taken into account when integrating a BESS within a WECS such as technological capability, operation size, and interaction with other systems. The BESS integrated into the WECS can be configured either as an aggregated unit serving the entire wind farm or as distributed unit installed in each wind turbine generator. Owing to the smoothing effect of the spatial distribution of WECS, the fluctuation of the total wind farm power is lower than power output of every single wind turbine generator. Hence, an aggregated BESS outperforms a distributed BESS under the same capacity [26]. In this paper, these BESS configurations have been used to clarify the proposed hybrid operation strategy due to the above following reasons. Fig. 4 shows the configuration of wind ESS for the proposed hybrid operation strategy. Here, the symbols PBESS, Pwind, and Ptotal are the output power of the BESS, the output power of the wind farm, and the combined power of the WECS and BESS, respectively. The aggregated BESS is charged/discharged through a power converter and is connected to the grid at the point of common coupling. Fig. 4Open in figure viewerPowerPoint Configuration of wind ESS 2.2.2 BESS control The main purpose of BESS control is not only to stabilise the power balance, but also to realise suitable management of energy storage so that the BESS does not become overloaded or run out of charge. Fig. 5 shows the block diagram of a controller for the BESS. In the BESS controller, is the output power command of the BESS, which is limited by the capacity. The SOC is calculated by integrating the power output of the BESS PBESS, TBESS is a time constant, and WBESS is the energy level of the BESS. Our study focused on relatively simple control considering the charge/discharge process and the SOC of the battery, without addressing the lifetime of the BESS. The basic controller design is used to keep the SOC of the battery in the proper range for reliable operation. Therefore, the SOC is maintained near 60% by the charge/discharge controller in this paper. Fig. 5Open in figure viewerPowerPoint BESS controller 3 Proposed hybrid operation strategy 3.1 DL operation for optimal operating point To participate in frequency regulation, it is necessary that the WECS should have sufficient power margin available at any instant. Thus, the PMSG wind generator needs to implement the DL operation to ensure a power margin. The DL control is dependent on the application of the overspeeding technique at the right suboptimal curve. The DL power reference can be calculated as (19)where (20)To utilise the proposed DL control method, the power margin Pmargin can be calculated as (21)Fig. 6 shows the DL optimal operating power point curve for a PMSG in high, medium, and low wind speed regions. To provide a power margin, the PMSG should operate along the 10% DL suboptimal curve. For a rated wind speed of V = 11 m/s, the PMSG should not operate at the maximum power point C, but instead at the point O, so that the system can obtain a 10% available power margin. If the frequency of the power system decreases, Pdel becomes a new output reference, Pref,new. The operating point is immediately moved from point O to point A using the KE reserve of the DL control. Then, the output is maintained during operation. At this time, the rotational speed should be continuously decreased because of the mismatch between the wind turbine output and the mechanical input. When point B is reached, the rotational speed and output are also decreased, following the MPPT curve. The rotational speed is stabilised at point C (the equilibrium point), which has equal mechanical output and the maximum possible power for the given rotational speed. This means that the system provides the maximum possible power until the frequency of the power system is stabilised. If the maximum possible power is higher than the output reference from the increased wind speed at 12 m/s, point C moves onto point A′ to verify output reference, and then point A′ moves to point B′ to increase the rotational speed. The proposed DL operation is used to dynamically control the q-axis current of the MSC, as shown in Fig. 7. Here, fsystem is the frequency of the power system, fnominal is the nominal frequency (60 Hz), and ωr is the speed adjustment rate. In our paper, the DL operation consists of two modes: 90 and 95% of the suboptimal power curve. Fig. 6Open in figure viewerPowerPoint DL suboptimal operating power point curve Fig. 7Open in figure viewerPowerPoint Configuration of DL controller 3.2 Pitch angle control Wind turbine systems typically operate at a wind speed ranging from 3 to 25 m/s, and the rated power can be extracted at a wind speed ranging from 12 to 16 m/s. The pitch angle controller is used to restrict the rotational speed to below the maximum speed. Fig. 8 shows the pitch angle controller used to regulate the rotational speed. When the generator power (or speed) is below the rated power (or the maximum speed), the pitch angle is set to zero to obtain maximum power. If the generated power is higher than the rated value, the pitch angle is adjusted to limit the power to the maximum rated value [27, 28]. This paper focuses on the ωm,limit of 1.2 pu to consider the reliable operation range of the PMSG based on the current control of the MSC. The operating rotational speed should be limited between 0.7 and 1.2 pu. This controller adjusts the pitch angle on the basis of a comparison with ωm and the reference pitch angle βref is defined by the PI controller. Fig. 8Open in figure viewerPowerPoint Pitch angle controller 3.3 Frequency support control KE discharge control uses the characteristic of the full converter of the PMSG, which makes output control possible over a large operating range. When frequency control is required, it is also possible to receive additional power output from the KE, which is stored in the wind turbine and rotor [11]. However, excessive KE discharge control may rapidly decrease the rotational speed and cause instability in the PMSG. To solve this issue, the proposed frequency support control based on KE discharge control uses active power control to maintain system stability. It attempts to provide a larger contribution to the short-term frequency regulation by drawing from the KE reserve, which can be calculated as (22)where J is the moment of inertia of the wind turbine. The KE reserve is sufficiently large that it can contribute significantly to frequency control. It can also improve the stable frequency recovery capability of the power system. Fig. 9 shows a schematic diagram of frequency support control. Under normal operating conditions, the PMSG attempts to control the output within the power margin in DL operation mode. If the frequency decreases because of disturbances in the power system, DL operation mode switches to KE discharge mode. Fig. 9Open in figure viewerPowerPoint Schematic diagram of frequency support control This change immediately increases the output Pdel of the PMSG by the power increment ΔPKE, and maintains its output by participating in frequency control during a support time Tsupport. In other words, Pout is increased by ΔPKE and the rotational speed decreases because of KE discharge. The relationship between the mechanical output Pm and the rotational speed ωm of the KE discharge control is defined as (23)When the output of the PMSG is equal to the maximum possible power, KE discharge mode operation must cease. After the PMSG has returned to normal operating conditions, the output can be recovered via the DL mode. Fig. 10 shows the modified rotor current control of the q-axis that performs the frequency support control. The trigger signal for changing to the KE discharge mode is determined according to the deviation of the frequency in the power system. The PMSG system operates as a KE discharge mode through the trigger signal when the critical frequency nadir is identified by the trigger module. Fig. 11 shows the frequency detection and trigger signal scheme; fref is the reference frequency. The event detector measures the power system frequency and the rate of change of frequency (ROCOF). It generates a trigger signal by continuous comparison of the predefined threshold value and the measured system frequency value. The ROCOF of the power system at the initial frequency event is determined as (24)where Hsystem is the equivalent inertia of the entire power system and ΔPloss is the lacked active power under a grid fault. Equation (24) indicates that the amount of lacked active power can be calculated using the ROCOF of the power system and it represents the security index of the grid fault. Fig. 10Open in figure viewerPowerPoint Modified q-axis rotor current control Fig. 11Open in figure viewerPowerPoint Frequency detection and trigger signal scheme 3.4 BESS operation The main objectives of operating the active power charge/discharge using the BESS are to stabilise WECS operation and create suitable management of energy storage, thereby maintaining a balance between the wind power and load demand. Reliable BESS operation is required such that the battery should be neither completely discharged nor overcharged. Thus, the BESS must be kept within the proper SOC levels to ensure the battery lifetime [29]. According to the load profiles, BESS operation can be divided into discharging, charging, and float modes. If the generated power is larger than the load demand, the extra energy is stored in the battery for future use. On the other hand, when the generated power is smaller than the load demand, the battery discharges the stored energy to the power system. Float mode is defined as that in which the generated power is equal to the load demand. Under the three-mode operation, the BESS can improve the reliability and stability of the wind power system and level the output of the wind generator against frequency fluctuation. The active power applied to the BESS is determined as (25)where Pload is the load demand and Pwind is the generated power output of the wind farm. Another important issue regarding the BESS can easily be depleted or overcharged if the battery does not take SOC of limits. The SOC of the battery should be kept within proper limits (i.e. between 30 and 90%) and needs to be determined accurately for the BESS operation. The operation of BESS is subject to the following limitations (26) (27)where and represent the maximum allowable charge and discharge powers for the BESS, and SOCMin and SOCMax are the minimum and maximum limits of SOC of the BESS, respectively. SOC(t) and the energy charging process of the BESS are calculated as (28) (29)where EBESS is the energy stored in the BESS, Erated,BESS is the rated energy capacity of the BESS, and ηc and ηl are the charge loss (%) and leakage loss factors (%/month) of the BESS, respectively. The SOC should always be maintained in the proper range for stable operation. 3.5 Strategy procedure As shown in Fig. 12, the proposed operation strategy is implemented in a sequential manner. Step 1: If the BESS reaches the maximum SOC li

Referência(s)