Artigo Revisado por pares

Multicenter, prospective, crossover trial comparing the door-knocking method with the conventional method for EUS-FNA of solid pancreatic masses (with videos)

2015; Elsevier BV; Volume: 83; Issue: 6 Linguagem: Inglês

10.1016/j.gie.2015.10.025

ISSN

1097-6779

Autores

Shuntaro Mukai, Takao Itoi, Reiko Ashida, Takayoshi Tsuchiya, Nobuhito Ikeuchi, Kentaro Kamada, Reina Tanaka, Junko Umeda, Ryosuke Tonozuka, Nobuyasu Fukutake, Koki Hoshi, Fuminori Moriyasu, Takuji Gotoda, Atsushi Irisawa,

Tópico(s)

Pancreatitis Pathology and Treatment

Resumo

There are currently no prospective, controlled trials of needle puncture speed in EUS-guided FNA (EUS-FNA). In this study, we prospectively evaluated the accuracy of histological diagnosis and the tissue acquisition rate of EUS-FNA by using the door-knocking method (DKM) with a standard 22-gauge needle.From November 2013 to August 2014, 82 patients who had solid pancreatic masses underwent EUS-FNA in which the conventional method (CM) and DKM with 2 respective passes in turn were used. The primary outcomes of this study were the accuracy of histological diagnosis and the rates of tissue acquisition in 2 FNA procedures by using these 2 methods.Although the successful tissue acquisition rate for histology was not significantly different with the DKM and CM (91.5% vs 89.0%, P = .37), the high cellularity tissue acquisition rate for histology with the DKM was significantly superior to that with the CM (54.9% vs 41.5%, P = .03). However, adequate quality rate and accuracy were not different in the DKM and CM (78.0% vs 80.5%, P = .42 and 76.8% vs 78.0%, P = .50, respectively). In the transgastric puncture group, although the adequate quality rate and accuracy were similar in the DKM and CM (84.1% vs 79.4%, P = .30 and 84.1% vs 76.2%, P = .11, respectively), the tissue acquisition rate tended to be higher with the DKM than the CM (93.7% vs 85.7%, P = .06). Moreover, the high cellularity tissue acquisition rate was significantly better with the DKM than the CM (63.5% vs 39.7%, P = .002). On the other hand, in the transduodenal puncture group, although the tissue acquisition rate was similar with the DKM and CM (84.2% vs 100%, P = .13), the adequate quality rate and accuracy were significantly lower with the DKM than with the CM (57.9% vs 84.2%, P = .03 and 52.6% vs 84.2%, P = .02, respectively).EUS-FNA by using a 22-gauge needle with the DKM did not improve the accuracy of histological diagnosis, but enabled acquisition of a larger amount of tissue specimen by using transgastric puncture. (http://www.umin.ac.jp/english/: UMIN000012127.).

Referência(s)