Artigo Acesso aberto Revisado por pares

Thermal Modelling Analysis of Spiral Wound Supercapacitor under Constant-Current Cycling

2015; Public Library of Science; Volume: 10; Issue: 10 Linguagem: Inglês

10.1371/journal.pone.0138672

ISSN

1932-6203

Autores

Kai Wang, Liwei Li, Huaixian Yin, Tiezhu Zhang, Wubo Wan,

Tópico(s)

Advanced Sensor and Energy Harvesting Materials

Resumo

A three-dimensional modelling approach is used to study the effects of operating and ambient conditions on the thermal behaviour of the spiral wound supercapacitor. The transient temperature distribution during cycling is obtained by using the finite element method with an implicit predictor-multicorrector algorithm. At the constant current of 2A, the results show that the maximum temperature appears in core area. After 5 cycles, the maximum temperature is 34.5°C, while in steady state, it's up to 42.5°C. This paper further studies the relationship between the maximum temperature and charge-discharge current. The maximum temperature will be more than 60°C after 5 cycles at the current of 4A, and cooling measurements should be taken at that time. It can provide thoughts on inner temperature field distribution and structure design of the spiral wound supercapacitor in working process.