On-line computer analysis and breath-by-breath graphical display of exercise function tests.
1973; American Physiological Society; Volume: 34; Issue: 1 Linguagem: Inglês
10.1152/jappl.1973.34.1.128
ISSN8750-7587
AutoresW. L. Beaver, K. Wasserman, Brian J. Whipp,
Tópico(s)Heart Rate Variability and Autonomic Control
ResumoArticleOn-line computer analysis and breath-by-breath graphical display of exercise function tests.W L Beaver, K Wasserman, and B J WhippW L Beaver, K Wasserman, and B J WhippPublished Online:01 Jan 1973https://doi.org/10.1152/jappl.1973.34.1.128MoreSectionsPDF (1 MB)Download PDF ToolsExport citationAdd to favoritesGet permissionsTrack citations ShareShare onFacebookTwitterLinkedInWeChat Previous Back to Top Next Download PDF FiguresReferencesRelatedInformation Cited ByTHE EFFECT of HIGH-INTENSITY INTERVAL PHYSICAL TRAINING ON THE ENERGY SUPPLY SYSTEM IN PATIENTS AFTER HEART SURGERY8 September 2022 | International journal of Innovative Medicine, No. 2Critical power (CP) testing: An accurate rapid method of fitness assessment during space missionsActa Astronautica, Vol. 198A Personal Biography of a Physiological Misnomer: The Anaerobic Threshold8 December 2021 | International Journal of Sports Medicine, Vol. 43, No. 05Progress Update and Challenges on V.O2max Testing and Interpretation3 September 2020 | Frontiers in Physiology, Vol. 11Karlman Wasserman, MD, PHD, Physiologist and Physician-Scientist: 1927–202016 October 2020 | Journal of Clinical Exercise Physiology, Vol. 9, No. 3Pulse wave transit time during exercise testing reflects the severity of heart disease in cardiac patientsDrug Discoveries & Therapeutics, Vol. 14, No. 1Breath‐by‐breath oxygen uptake during running: Effects of different calculation algorithms25 October 2019 | Experimental Physiology, Vol. 104, No. 12Cardiopulmonary exercise testing and echocardiographic exam: an useful interaction3 December 2019 | Cardiovascular Ultrasound, Vol. 17, No. 1Differences in alveolo-capillary equilibration in healthy subjects on facing O2 demand13 November 2019 | Scientific Reports, Vol. 9, No. 1Impact of data averaging strategies on V̇O 2max assessment: Mathematical modeling and reliability18 July 2019 | Scandinavian Journal of Medicine & Science in Sports, Vol. 29, No. 10Effects of a lumbar-type hybrid assistive limb on cardiopulmonary burden during squat exercise in healthy subjectsJournal of Clinical Neuroscience, Vol. 66Comparison of different breath-by-breath gas exchange algorithms using a gas exchange simulation systemRespiratory Physiology & Neurobiology, Vol. 266Practical Considerations for Assessing Pulmonary Gas Exchange and Ventilation During Flume Swimming Using the MetaSwim Metabolic CartJournal of Strength and Conditioning Research, Vol. 33, No. 7Effects of a cyborg-type robot suit HAL on cardiopulmonary burden during exercise in normal subjects29 November 2018 | European Journal of Applied Physiology, Vol. 119, No. 2New Approaches in Measuring to the Calculations and Analysis Modelling of Breath-by-Breath Alveolar Gas Exchanges in Humans19 March 2019Exercise Testing11 December 2018Metabolic Transitions and Muscle Metabolic Stability: Effects of Exercise TrainingAccuracy and Precision of the COSMED K5 Portable Analyser21 December 2018 | Frontiers in Physiology, Vol. 9Quantitative Contact-Less Estimation of Energy Expenditure from Video and 3D Imagery26 July 2018 | Sensors, Vol. 18, No. 8Assessing breath-by-breath alveolar gas exchange: is the contiguity in time of breaths mandatory?15 March 2018 | European Journal of Applied Physiology, Vol. 118, No. 6Open-circuit respirometry: real-time, laboratory-based systems4 May 2018 | European Journal of Applied Physiology, Vol. 118, No. 5Open-circuit respirometry: a historical review of portable gas analysis systems17 October 2017 | European Journal of Applied Physiology, Vol. 117, No. 12Clinical significance of the overshoot phenomena of respiratory gas indices during recovery from maximal exercise testingJournal of Cardiology, Vol. 70, No. 6Algorithm to improve accuracy of energy expended in a room calorimeter20 October 2016 | Medical & Biological Engineering & Computing, Vol. 55, No. 8Graphical Data Display for Clinical Cardiopulmonary Exercise TestingAnnals of the American Thoracic Society, Vol. 14, No. Supplement_1Exercise Testing, Supplemental Oxygen, and HypoxiaAnnals of the American Thoracic Society, Vol. 14, No. Supplement_1Pump speed modulations and sub-maximal exercise tolerance in left ventricular assist device recipients: A double-blind, randomized trialThe Journal of Heart and Lung Transplantation, Vol. 36, No. 1The constant work rate critical power protocol overestimates ramp incremental exercise performance27 October 2016 | European Journal of Applied Physiology, Vol. 116, No. 11-12On the inaccuracy of breath-by-breath metabolic gas exchange systemsRespiratory Physiology & Neurobiology, Vol. 233Gas analyzer's drift leads to systematic error in maximal oxygen uptake and maximal respiratory exchange ratio determination30 October 2015 | Frontiers in Physiology, Vol. 6The effect of neoadjuvant chemotherapy on physical fitness and survival in patients undergoing oesophagogastric cancer surgeryEuropean Journal of Surgical Oncology (EJSO), Vol. 40, No. 10A ‘ramp-sprint’ protocol to characterise indices of aerobic function and exercise intensity domains in a single laboratory test3 June 2014 | European Journal of Applied Physiology, Vol. 114, No. 9Effect of Work and Recovery Durations on W′ Reconstitution during Intermittent ExerciseMedicine & Science in Sports & Exercise, Vol. 46, No. 7Inter-individual differences in control of alveolar capillary blood volume in exercise and hypoxiaRespiratory Physiology & Neurobiology, Vol. 190Ventilatory regulation of arterial H+ (pH) during exerciseRespiratory Physiology & Neurobiology, Vol. 190Minute ventilation and heart rate relationship for estimation of the ventilatory compensation point at high altitude: a pilot study1 March 2013 | Extreme Physiology & Medicine, Vol. 2, No. 1Anaerobic threshold, is it a magic number to determine fitness for surgery?21 February 2013 | Perioperative Medicine, Vol. 2, No. 1Muscle metabolism and activation heterogeneity by combined 31P chemical shift and T2 imaging, and pulmonary O2 uptake during incremental knee-extensor exerciseDaniel T. Cannon, Franklyn A. Howe, Brian J. Whipp†, Susan A. Ward, Dominick J. McIntyre, Christophe Ladroue, John R. Griffiths, Graham J. Kemp, and Harry B. Rossiter15 September 2013 | Journal of Applied Physiology, Vol. 115, No. 6Professor Brian J. Whipp: an obituary6 February 2013 | European Journal of Applied Physiology, Vol. 113, No. 4Comparison of Step-Wise and Ramp-Wise Incremental Rowing Exercise Tests and 2000-m Rowing Ergometer PerformanceInternational Journal of Sports Physiology and Performance, Vol. 8, No. 2Clinical Usefulness of Response Profiles to Rapidly Incremental Cardiopulmonary Exercise TestingPulmonary Medicine, Vol. 2013Accuracy and precision of CPET equipment: A comparison of breath-by-breath and mixing chamber systems31 October 2012 | Journal of Medical Engineering & Technology, Vol. 37, No. 1A novel cardiopulmonary exercise test protocol and criterion to determine maximal oxygen uptake in chronic heart failureT. Scott Bowen, Daniel T. Cannon, Gordon Begg, Vivek Baliga, Klaus K. Witte, and Harry B. Rossiter1 August 2012 | Journal of Applied Physiology, Vol. 113, No. 3Modeling the Expenditure and Reconstitution of Work Capacity above Critical PowerMedicine & Science in Sports & Exercise, Vol. 44, No. 8A Simplified Approach for the Estimation of the Ventilatory Compensation PointMedicine & Science in Sports & Exercise, Vol. 44, No. 4Experimental approaches to the study of the mechanics of breathing during exerciseRespiratory Physiology & Neurobiology, Vol. 180, No. 2-3Comparação de indicadores físicos e fisiológicos entre atletas profissionais de futsal e futebolMotriz: Revista de Educação Física, Vol. 18, No. 1Validation of a new mixing chamber system for breath-by-breath indirect calorimetryApplied Physiology, Nutrition, and Metabolism, Vol. 37, No. 1Effects of Priming Exercise on V˙O2 Kinetics and the Power-Duration RelationshipMedicine & Science in Sports & Exercise, Vol. 43, No. 11Exercise intolerance at high altitude (5050m): Critical power and W′Respiratory Physiology & Neurobiology, Vol. 177, No. 3The effect of pedal rate on pulmonary O2 uptake kinetics during very heavy intensity exercise in trained and untrained teenage boysRespiratory Physiology & Neurobiology, Vol. 177, No. 2Muscle fiber recruitment and the slow component of O2 uptake: constant work rate vs. all-out sprint exerciseAnni Vanhatalo, David C. Poole, Fred J. DiMenna, Stephen J. Bailey, and Andrew M. Jones1 March 2011 | American Journal of Physiology-Regulatory, Integrative and Comparative Physiology, Vol. 300, No. 3Algorithms, modelling and $$ \dot{V}{\text{O}}_{ 2} $$ kinetics27 February 2010 | European Journal of Applied Physiology, Vol. 111, No. 3Stress responses during aerobic exercise in relation to motivational dominance and stateJournal of Sports Sciences, Vol. 29, No. 3Acute and chronic effects of dietary nitrate supplementation on blood pressure and the physiological responses to moderate-intensity and incremental exerciseAnni Vanhatalo, Stephen J. Bailey, Jamie R. Blackwell, Fred J. DiMenna, Toby G. Pavey, Daryl P. Wilkerson, Nigel Benjamin, Paul G. Winyard, and Andrew M. Jones1 October 2010 | American Journal of Physiology-Regulatory, Integrative and Comparative Physiology, Vol. 299, No. 4The influence of priming exercise on oxygen uptake, cardiac output, and muscle oxygenation kinetics during very heavy-intensity exercise in 9- to 13-yr-old boysAlan R. Barker, Andrew M. Jones, and Neil Armstrong1 August 2010 | Journal of Applied Physiology, Vol. 109, No. 2Cardiac shunt calculations made easy: A case-based approach1 June 2010 | Catheterization and Cardiovascular Interventions, Vol. 76, No. 1Perceptual and cognitive responses during exercise: Relationships with metamotivational state and dominanceEuropean Journal of Sport Science, Vol. 10, No. 3Effect of recovery duration from prior exhaustive exercise on the parameters of the power-duration relationshipC. Ferguson, H. B. Rossiter, B. J. Whipp, A. J. Cathcart, S. R. Murgatroyd, and S. A. Ward1 April 2010 | Journal of Applied Physiology, Vol. 108, No. 4Human Exercise-Induced Circulating Progenitor Cell Mobilization Is Nitric Oxide-Dependent and Is Blunted in South Asian MenArteriosclerosis, Thrombosis, and Vascular Biology, Vol. 30, No. 4Recommendations for Improved Data Processing from Expired Gas Analysis Indirect CalorimetrySports Medicine, Vol. 40, No. 2Support vector machines for aerobic fitness prediction of athletesExpert Systems with Applications, Vol. 36, No. 2Algorithm for transient response of whole body indirect calorimeter: deconvolution with a regularization parameterKumpei Tokuyama, Hitomi Ogata, Yasuko Katayose, and Makoto Satoh1 February 2009 | Journal of Applied Physiology, Vol. 106, No. 2Lactate threshold at the same fat-free mass and age is larger in men than women15 August 2008 | European Journal of Applied Physiology, Vol. 104, No. 5Estimation of the exercise ventilatory compensation point by the analysis of the relationship between minute ventilation and heart rate14 June 2008 | European Journal of Applied Physiology, Vol. 104, No. 1A 3-min All-out Cycling Test Is Sensitive to a Change in Critical PowerMedicine & Science in Sports & Exercise, Vol. 40, No. 9Muscle phosphocreatine and pulmonary oxygen uptake kinetics in children at the onset and offset of moderate intensity exercise3 January 2008 | European Journal of Applied Physiology, Vol. 102, No. 6Pathophysiological adaptations to walking and cycling in primary pulmonary hypertension3 November 2007 | European Journal of Applied Physiology, Vol. 102, No. 4Robustness of a 3 min all-out cycling test to manipulations of power profile and cadence in humans7 December 2007 | Experimental Physiology, Vol. 93, No. 3Cardiopulmonary responses to treadmill and cycle ergometry exercise in patients with peripheral vascular diseaseJournal of Vascular Surgery, Vol. 47, No. 1Effects of prior very-heavy intensity exercise on indices of aerobic function and high-intensity exercise toleranceC. Ferguson, B. J. Whipp, A. J. Cathcart, H. B. Rossiter, A. P. Turner, and S. A. Ward1 September 2007 | Journal of Applied Physiology, Vol. 103, No. 3Affective responses of inactive women to a maximal incremental exercise test: A test of the dual-mode modelPsychology of Sport and Exercise, Vol. 8, No. 4Scaling of lactate threshold by peak oxygen uptake and by fat-free mass 0�67Clinical Physiology and Functional Imaging, Vol. 27, No. 3Determination of Critical Power Using a 3-min All-out Cycling TestMedicine & Science in Sports & Exercise, Vol. 39, No. 3Estudo comparativo do consumo de oxigênio e limiar anaeróbio em um teste de esforço progressivo entre atletas profissionais de futebol e futsalRevista Brasileira de Medicina do Esporte, Vol. 12, No. 6Time required for the restoration of normal heavy exercise V̇o2 kinetics following prior heavy exerciseMark Burnley, Jonathan H. Doust, and Andrew M. Jones1 November 2006 | Journal of Applied Physiology, Vol. 101, No. 5A 3-min All-Out Test to Determine Peak Oxygen Uptake and the Maximal Steady StateMedicine & Science in Sports & Exercise, Vol. 38, No. 11Influence of acute plasma volume expansion on V̇o2 kinetics, V̇o2peak, and performance during high-intensity cycle exerciseNicolas J. A. Berger, Iain T. Campbell, Daryl P. Wilkerson, and Andrew M. Jones1 September 2006 | Journal of Applied Physiology, Vol. 101, No. 3Influence of caffeine on perception of effort, metabolism and exercise performance following a high-fat mealJournal of Sports Sciences, Vol. 24, No. 8Indices of electromyographic activity and the “slow” component of oxygen uptake kinetics during high-intensity knee-extension exercise in humans10 May 2006 | European Journal of Applied Physiology, Vol. 97, No. 4VE / VCO2 slope is associated with abnormal resting haemodynamics and is a predictor of long-term survival in chronic heart failure11 June 2006 | European Journal of Heart Failure, Vol. 8, No. 4Statement on cardiopulmonary exercise testing in chronic heart failure due to left ventricular dysfunction: recommendations for performance and interpretation Part II: How to perform cardiopulmonary exercise testing in chronic heart failureEuropean Journal of Cardiovascular Prevention & Rehabilitation, Vol. 13, No. 3Influence of blood donation on O 2 uptake on-kinetics, peak O 2 uptake and time to exhaustion during severe-intensity cycle exercise in humans24 March 2006 | Experimental Physiology, Vol. 91, No. 3Oxygen Consumption During Machine-Assisted and Unassisted Walking: A Pilot Study in Hemiplegic and Healthy HumansArchives of Physical Medicine and Rehabilitation, Vol. 87, No. 4On the modeling of breath-by-breath oxygen uptake kinetics at the onset of high-intensity exercises: simulated annealing vs. GRG2 methodOlivier Bernard, Olivier Alata, and Marc Francaux1 March 2006 | Journal of Applied Physiology, Vol. 100, No. 3A test to establish maximum O2 uptake despite no plateau in the O2 uptake response to ramp incremental exerciseH. B. Rossiter, J. M. Kowalchuk, and B. J. Whipp1 March 2006 | Journal of Applied Physiology, Vol. 100, No. 3Oxygen Uptake and Muscle Desaturation Kinetics during Intermittent CyclingMedicine & Science in Sports & Exercise, Vol. 38, No. 3Maximal oxygen uptake at the same fat-free mass is greater in men than womenClinical Physiology and Functional Imaging, Vol. 26, No. 1Effects of supervised cardiovascular training program on exercise tolerance, aerobic capacity, and quality of life in patients with systemic lupus erythematosus1 January 2005 | Arthritis & Rheumatism, Vol. 53, No. 6Validity and reliability of selected commercially available metabolic analyzer systemsScandinavian Journal of Medicine and Science in Sports, Vol. 15, No. 5Diagnosis of Unexplained Dyspnea4 April 2013Effects of Prior Warm-up Regime on Severe-Intensity Cycling PerformanceMedicine & Science in Sports & Exercise, Vol. 37, No. 5Absence of long-term modulation of ventilation by dead-space loading during moderate exercise in humans14 October 2004 | European Journal of Applied Physiology, Vol. 93, No. 4Effect of heliox on lung dynamic hyperinflation, dyspnea, and exercise endurance capacity in COPD patientsPaolo Palange, Gabriele Valli, Paolo Onorati, Rosa Antonucci, Patrizia Paoletti, Alessia Rosato, Felice Manfredi, and Pietro Serra1 November 2004 | Journal of Applied Physiology, Vol. 97, No. 5Ventilatory Responses to Inhaled Carbon Dioxide, Hypoxia, and Exercise in Idiopathic HyperventilationAmerican Journal of Respiratory and Critical Care Medicine, Vol. 170, No. 2Control Strategies for Integration of Electric Motor Assist and Functional Electrical Stimulation in Paraplegic Cycling: Utility for Exercise Testing and Mobile CyclingIEEE Transactions on Neural Systems and Rehabilitation Engineering, Vol. 12, No. 1OPTIMIZING BREATH-BY-BREATH &OV0312;O2 MEASUREMENTSMedicine & Science in Sports & Exercise, Vol. 36, No. 3The maximally attainable V̇o2 during exercise in humans: the peak vs. maximum issueJ. R. Day, H. B. Rossiter , E. M. Coats, A. Skasick, and B. J. Whipp1 November 2003 | Journal of Applied Physiology, Vol. 95, No. 5Effects of dichloroacetate on V̇o2 and intramuscular 31P metabolite kinetics during high-intensity exercise in humansH. B. Rossiter, S. A. Ward, F. A. Howe, D. M. Wood, J. M. Kowalchuk, J. R. Griffiths, and B. J. Whipp1 September 2003 | Journal of Applied Physiology, Vol. 95, No. 3Intensity-dependent tolerance to exercise after attaining V̇o2 max in humansEdward M. Coats, Harry B. Rossiter, James R. Day, Akira Miura, Yoshiyuki Fukuba, and Brian J. Whipp1 August 2003 | Journal of Applied Physiology, Vol. 95, No. 2CPX/D Underestimates &OV0312;O2 in Athletes Compared with an Automated Douglas Bag SystemMedicine & Science in Sports & Exercise, Vol. 35, No. 8ATS/ACCP Statement on Cardiopulmonary Exercise TestingAmerican Journal of Respiratory and Critical Care Medicine, Vol. 167, No. 2The Respiratory SystemThe Effects of Food Intake on Muscle Oxygen ConsumptionDynamics of intramuscular 31P-MRS Pi peak splitting and the slow components of PCr and O2 uptake during exerciseH. B. Rossiter, S. A. Ward, F. A. Howe, J. M. Kowalchuk, J. R. Griffiths, and B. J. Whipp1 December 2002 | Journal of Applied Physiology, Vol. 93, No. 6Ventilatory Efficiency during Exercise in Healthy SubjectsAmerican Journal of Respiratory and Critical Care Medicine, Vol. 166, No. 11Lower reference limit for maximal oxygen uptake in men and womenClinical Physiology and Functional Imaging, Vol. 22, No. 5An Elevated Breathing Reserve Index at the Lactate Threshold Is a Predictor of Mortality in Patients with Cystic Fibrosis Awaiting Lung TransplantationAmerican Journal of Respiratory and Critical Care Medicine, Vol. 165, No. 12Dynamic asymmetry of phosphocreatine concentration and O 2 uptake between the on‐ and off‐transients of moderate‐ and high‐intensity exercise in humans1 June 2002 | The Journal of Physiology, Vol. 541, No. 3Association of lung perfusion disparity and mortality in patients with cystic fibrosis awaiting lung transplantationThe Journal of Heart and Lung Transplantation, Vol. 21, No. 2Gas Exchange Detection of Exercise-Induced Right-to-Left Shunt in Patients With Primary Pulmonary HypertensionCirculation, Vol. 105, No. 1Early recovery of oxygen kinetics after submaximal exercise test predicts functional capacity in patients with chronic heart failure3 December 2001 | European Journal of Heart Failure, Vol. 3, No. 6Effects of prior exercise on oxygen uptake and phosphocreatine kinetics during high‐intensity knee‐extension exercise in humans1 November 2001 | The Journal of Physiology, Vol. 537, No. 1Influence of exercise intensity on the on‐ and off‐transient kinetics of pulmonary oxygen uptake in humans1 June 2001 | The Journal of Physiology, Vol. 533, No. 3Pruebas de ejercicio cardiopulmonarArchivos de Bronconeumología, Vol. 37, No. 7Automated Metabolic Gas Analysis SystemsSports Medicine, Vol. 31, No. 12Exercise testing in children: an alternative approach10 November 2010 | Ergonomics, Vol. 43, No. 10Intersample fluctuations in phosphocreatine concentration determined by 31 P‐magnetic resonance spectroscopy and parameter estimation of metabolic responses to exercise in humans1 October 2000 | The Journal of Physiology, Vol. 528, No. 2Utility of metabolic exercise testing in distinguishing hypertrophic cardiomyopathy from physiologic left ventricular hypertrophy in athletesJournal of the American College of Cardiology, Vol. 36, No. 3Improvement of Exercise Tolerance by Single Lead VDD Pacemaker: Evaluation Using Cardiopulmonary Exercise TestPacing and Clinical Electrophysiology, Vol. 23, No. 9Utility of cardiopulmonary exercise in the assessment of clinical determinants of functional capacity in hypertrophic cardiomyopathyThe American Journal of Cardiology, Vol. 86, No. 2Ventilatory and metabolic adaptations to walking and cycling in patients with COPDPaolo Palange, Silvia Forte, Paolo Onorati, Felice Manfredi, Pietro Serra, and S. Carlone1 May 2000 | Journal of Applied Physiology, Vol. 88, No. 5V˙o2 kinetics reveal a central limitation at the onset of subthreshold exercise in heart transplant recipientsBertrand Mettauer, Quan Ming Zhao, Eric Epailly, Anne Charloux, Eliane Lampert, Bernadette Heitz-Naegelen, François Piquard, Pietro E. di Prampero, and Jean Lonsdorfer1 April 2000 | Journal of Applied Physiology, Vol. 88, No. 4New graphical method for evaluating gas exchange in congestive heart failureMedicine & Science in Sports & Exercise, Vol. 32, No. 4Effects of ‘Cool-Down’ During Exercise Recovery on Cardiopulmonary Systems in Patients With Coronary Artery DiseaseJapanese Circulation Journal, Vol. 64, No. 3Simultaneous determination of muscle31P and O2 uptake kinetics during whole body NMR spectroscopyB. J. Whipp, H. B. Rossiter, S. A. Ward, D. Avery, V. L. Doyle, F. A. Howe, and J. R. Griffiths1 February 1999 | Journal of Applied Physiology, Vol. 86, No. 2Effects of inhaled dry powder ipratropium bromide on recovery from exercise of horses with COPDEquine Veterinary Journal, Vol. 31, No. 1Ventilatory and Cardiovascular Responses to Inspired He-O 2 during Exercise in Chronic Obstructive Pulmonary DiseaseAmerican Journal of Respiratory and Critical Care Medicine, Vol. 158, No. 6Effect of Reduced Body Weight on Muscle Aerobic Capacity in Patients With COPDChest, Vol. 114, No. 1Breathing Reserve at the Lactate Threshold to Differentiate a Pulmonary Mechanical From Cardiovascular Limit to ExerciseChest, Vol. 113, No. 4Does an acute COPD crisis modify the cardiorespiratory and ventilatory adjustments to exercise in horses?T. Art, D. H. Duvivier, D. Votion, N. Anciaux, S. Vandenput, W. M. Bayly, and P. Lekeux1 March 1998 | Journal of Applied Physiology, Vol. 84, No. 3Erreurs à ne pas commettre lors de la réalisation d'un exercice de détermination de la consommation maximale d'oxygèneScience & Sports, Vol. 13, No. 4Skeletal Muscle Oxygenation and Oxygen Uptake Kinetics Following Constant Work Rate Exercise in Chronic Congestive Heart FailureThe American Journal of Cardiology, Vol. 80, No. 10Effect of acute bicarbonate administration on exercise responses of COPD patientsMedicine &Science in Sports &Exercise, Vol. 29, No. 6Heart rate performance curve during incremental cycle ergometer exercise in healthy young male subjectsMedicine &Science in Sports &Exercise, Vol. 29, No. 6Effect of exercise training and detraining on gas exchange kinetics in patients with chronic obstructive pulmonary disease5 November 2010 | Clinical Physiology, Vol. 17, No. 3Effects of Dihydrocodeine on Chemosensitivity and Exercise Tolerance in Patients With Chronic Heart FailureJournal of the American College of Cardiology, Vol. 29, No. 1Delay time adjustments to minimize errors in breath-by-breath measurement of V˙o2 during exerciseDavid N. Proctor and Kenneth C. Beck1 December 1996 | Journal of Applied Physiology, Vol. 81, No. 6Estimating exercise stroke volume from asymptotic oxygen pulse in humansBrian J. Whipp, Michael B. Higgenbotham, and Frederick C. Cobb1 December 1996 | Journal of Applied Physiology, Vol. 81, No. 6Contribution of peripheral chemoreceptors to ventilation and the effects of their suppression on exercise tolerance in chronic heart failure.Heart, Vol. 76, No. 6Evaluation of Exercise Capacity Using Submaximal Exercise at a Constant Work Rate in Patients With Cardiovascular DiseaseCirculation, Vol. 91, No. 6Changes in skeletal muscle oxygenation during incremental exercise measured with near infrared spectroscopyEuropean Journal of Applied Physiology and Occupational Physiology, Vol. 70, No. 6Oxygen uptake kinetics are determined by cardiac function at onset of exercise rather than peak exercise in patients with prior myocardial infarction.Circulation, Vol. 90, No. 5A method for estimating bicarbonate buffering of lactic acid during constant work rate exerciseEuropean Journal of Applied Physiology and Occupational Physiology, Vol. 69, No. 4BEHIND THE SCENES OF CARDIOPULMONARY EXERCISE TESTINGClinics in Chest Medicine, Vol. 15, No. 2Training-induced modifications in cardiorespiratory and ventilatory measurements in Thoroughbred horsesEquine Veterinary Journal, Vol. 25, No. 6Continuous Fick Cardiac Output Measurement During Exercise by Monitoring of Mixed Venous Oxygen Saturation and Oxygen UptakeChest, Vol. 104, No. 2Reduction of exercise-induced ventricular arrhythmias in mild symptomatic heart failure by benazeprilAmerican Heart Journal, Vol. 125, No. 3Effect of a Booster Vaccination against Influenza and Equine Herpes Virus on Cardio-Respiratory Adjustments to Strenuous Exercise and Training in Thoroughbred HorsesJournal of Veterinary Medicine Series A, Vol. 40, No. 1-10Continuous cardiac output monitoring by the Fick methodCatheterization and Cardiovascular Diagnosis, Vol. 28, No. 1Evaluation of Breath-by-Breath Measurement of Respiratory Gas Exchange in Pediatric Exercise TestingChest, Vol. 102, No. 1Pulmonary gas exchange during intermittent ventilation in the American alligatorRespiration Physiology, Vol. 88, No. 1-2The respiratory system as an exercise limiting factor in normal sedentary subjectsEuropean Journal of Applied Physiology and Occupational Physiology, Vol. 64, No. 2The role of fitness on VO2 and VCO2 kinetics in response to proportional step increases in work rateEuropean Journal of Applied Physiology and Occupational Physiology, Vol. 63, No. 2Breath-by-breath measurement of oxygen consumption and Fio 2 -Feo 2 with increased oxygen demandActa Anaesthesiologica Scandinavica, Vol. 35, No. 3Advances in the Computerized Breath-by-Breath MethodO2 Uptake in hyperthyroidism during constant work rate and incremental exerciseEuropean Journal of Applied Physiology and Occupational Physiology, Vol. 62, No. 4A lung function information systemJournal of Biomedical Engineering, Vol. 13, No. 1Mechanics of breathing during strenuous exercise in thoroughbred horsesRespiration Physiology, Vol. 82, No. 3The physical strain of dairy farmingErgonomics, Vol. 33, No. 12Determining the Reasons for Weight Gain Following Smoking Cessation: Current Findings, Methodological Issues, and Future Directions for ResearchAnnals of Behavioral Medicine, Vol. 11, No. 4Estimating Arterial PCO2 from Flow-Weighted and Time-Average Alveolar PCO2 During ExerciseGas-Exchange Inferences for the Proportionality of the Cardiopulmonary Responses During Phase 1 of ExerciseBreath-By-Breath Gas Exchange: Data Collection and AnalysisA programmable system for acquisition and reduction of respiratory physiological dataAnnals of Biomedical Engineering, Vol. 17, No. 1Comparison of topical timolol vs betaxolol on cardiopulmonary exercise performance in healthy volunteers27 May 2009 | Acta Ophthalmologica, Vol. 66, No. 4The Importance of Different Atrioventricular Intervals for Exercise Capacity30 June 2006 | Pacing and Clinical Electrophysiology, Vol. 11, No. 7Upper Extremity Exercise Training in Chronic Obstructive Pulmonary DiseaseChest, Vol. 93, No. 4Impaired Exercise Tolerance After Inferior Vena Caval InterruptionChest, Vol. 93, No. 4Cardiopulmonary and gas exchange responses to acute strenuous exercise at 1,270 meters in sickle cell traitThe American Journal of Medicine, Vol. 84, No. 3Pulmonary Function Tests Cannot Predict Exercise-Induced Hypoxemia in Chronic Obstructive Pulmonary DiseaseChest, Vol. 93, No. 3Cardiopulmonary measurementsPropagation of measurement errors in oxygen consumption algorithmsMedical & Biological Engineering & Computing, Vol. 25, No. 4An on-line microcomputer-based metabolic monitoring systemInternational Journal of Industrial Ergonomics, Vol. 1, No. 3Breath-by-breath measurement of alveolar gas exchange with a slow-response gas analyserMedical & Biological Engineering & Computing, Vol. 25, No. 2Measurement and interpretation of maximal oxygen uptake in patients with chronic cardiac or circulatory failureJournal of Clinical Monitoring, Vol. 3, No. 1Pulmonary Circulation in ExerciseRespiratory Control During Exercise1 January 2011Analysis of breath-by-breath exercise data from field studiesInternational Journal of Clinical Monitoring and Computing, Vol. 2, No. 3Comparison of Isocapnic Hyperventilation and Walking Exercise Training at Home in Pulmonary RehabilitationChest, Vol. 90, No. 2Time constant and transport delay determination of the gas analyzerMathematical Modelling, Vol. 7, No. 9-12Computer Applications in Pulmonary Function TestingMicroprocessor-based system for on-line analysis of respiratory responses to exerciseComputer Programs in Biomedicine, Vol. 19, No. 2-3A computer-based data acquisition system for breathing and exercise entrainment studiesComputers in Biology and Medicine, Vol. 15, No. 5On-Line Minicomputerized Measurement of Cardiopulmonary Function On a Breath-By-Breath BasisPsychophysiology, Vol. 22, No. 1Advantages of the Computerized Breath-by-Breath Method for the Interpretation of Spiroergometric DataA new method for breath-to-breath determination of oxygen flux across the alveolar membraneEuropean Journal of Applied Physiology and Occupational Physiology, Vol. 52, No. 2Dissociation between $$\dot V_{O_2 \max }$$ and ventilatory threshold responses to endurance trainingEuropean Journal of Applied Physiology and Occupational Physiology, Vol. 53, No. 3A computerized mass spectrometer and flowmeter system for respiratory gas measurementsAnnals of Biomedical Engineering, Vol. 11, No. 2A Standard Artificial Lung for System Calibration in Physiological Gas Exchange MeasurementOxygen utilization and ventilation during exercise in patients with chronic cardiac failure.Circulation, Vol. 65, No. 6Description of a Low Cost Microcomputer System Interfaced to Exercise Stress Testing EquipmentResearch Quarterly for Exercise and Sport, Vol. 53, No. 1Sensitivity of Breath-to-Breath Gas Exchange Measurements to Expiratory Flow ErrorsIEEE Transactions on Biomedical Engineering, Vol. BME-28, No. 11Accelerated respiratory response to moderate exercise in late pregnancyRespiration Physiology, Vol. 45, No. 3DOUBLE-BLIND TRIAL OF CHRONIC ORAL BETA BLOCKADE IN CONGESTIVE CARDIOMYOPATHYThe Lancet, Vol. 318, No. 8245Online computer for assessing respiratory and metabolic function during exerciseMedical & Biological Engineering & Computing, Vol. 19, No. 3HUMORAL CONTROL OF VENTILATION DURING EXERCISE IN MANA simple method for measuring oxygen uptake on a single breath basisEuropean Journal of Applied Physiology and Occupational Physiology, Vol. 45, No. 1The relation of ventilation to metabolic rate during moderate exercise in manEuropean Journal of Applied Physiology and Occupational Physiology, Vol. 44, No. 2Long-Term Vasodilator Therapy with Trimazosin in Chronic Cardiac FailureNew England Journal of Medicine, Vol. 303, No. 5A Comprehensive Pulmonary Data Processing SystemMechanism of the isoproterenol hyperpnea in the catRespiration Physiology, Vol. 38, No. 3Fasting as a provocative test in neuromuscular diseasesMetabolism, Vol. 28, No. 6Computers in Lung Function TestsOn-Line Acquisition of Pulmonary Gas Exchange DataIEEE Transactions on Biomedical Engineering, Vol. BME-25, No. 1Reporting Lung Function Tests: Criteria and Methods, Including the Use of Computers [ Abridged ]1 September 2016 | Proceedings of the Royal Society of Medicine, Vol. 70, No. 3Reporting Lung Function Tests: Criteria and Methods, Including the Use of Computers [ Abridged ]1 September 2016 | Proceedings of the Royal Society of Medicine, Vol. 70, No. 3Battery of single-breath tests for rapid measurement of pulmonary function using a respiratory mass spectrometerPneumonologie Pneumonology, Vol. 151, No. 4Role of the Carotid Bodies in Breath-HoldingNew England Journal of Medicine, Vol. 290, No. 15A new technique for recording respiratory transients at the start of exerciseRespiration Physiology, Vol. 20, No. 1Respiratory responses to intermittent and prolonged exercise in a hot-dry environmentLife Sciences, Vol. 14, No. 1Equipment, measurements and quality controlExercise testing for pre-operative evaluation More from this issue > Volume 34Issue 1January 1973Pages 128-32 https://doi.org/10.1152/jappl.1973.34.1.128PubMed4697371History Published online 1 January 1973 Published in print 1 January 1973 Metrics
Referência(s)