Resumo

This paper describes a long-term operation of the 2.45-GHz microwave proton source at Peking University. The DC proton beam of 50–55 mA with energy of 35 keV has been run for 306 hours continuously. Total beam availability, defined as 35-keV beam-on time divided by elapsed time, is higher than 99%. Water cooling machine failures cause all the downtime, and no plasma generator failure or high voltage breakdown is observed. The longest uninterrupted run time is 122 hours.