Revisão Acesso aberto Revisado por pares

Human Immunodeficiency Virus Diagnostic Testing: 30 Years of Evolution

2016; American Society for Microbiology; Volume: 23; Issue: 4 Linguagem: Inglês

10.1128/cvi.00053-16

ISSN

1556-6811

Autores

Thomas S. Alexander,

Tópico(s)

HIV/AIDS drug development and treatment

Resumo

A concern during the early AIDS epidemic was the lack of a test to identify individuals who carried the virus. The first HIV antibody test, developed in 1985, was designed to screen blood products, not to diagnose AIDS. The first-generation assays detected IgG antibody and became positive 6 to 12 weeks postinfection. False-positive results occurred; thus, a two-test algorithm was developed using a Western blot or immunofluorescence test as a confirmatory procedure. The second-generation HIV test added recombinant antigens, and the third-generation HIV tests included IgM detection, reducing the test-negative window to approximately 3 weeks postinfection. Fourth- and fifth-generation HIV assays added p24 antigen detection to the screening assay, reducing the test-negative window to 11 to 14 days. A new algorithm addressed the fourth-generation assay's ability to detect both antibody and antigen and yet not differentiate between them. The fifth-generation HIV assay provides separate antigen and antibody results and will require yet another algorithm. HIV infection may now be detected approximately 2 weeks postexposure, with a reduced number of false-positive results.