Artigo Revisado por pares

Method to diagnose open‐circuit faults in active power switches and clamp‐diodes of three‐level neutral‐point clamped inverters

2016; Institution of Engineering and Technology; Volume: 10; Issue: 7 Linguagem: Inglês

10.1049/iet-epa.2015.0644

ISSN

1751-8679

Autores

Mohsen Bandar Abadi, André M. S. Mendes, Sérgio M. A. Cruz,

Tópico(s)

Induction Heating and Inverter Technology

Resumo

A new real-time method able to diagnose multiple semiconductor open-circuit (OC) faults in a three-level neutral-point clamped inverter is introduced in this paper. The proposed diagnostic method is based on the evaluation of the output pole voltages and output currents of the inverter. The proposed method allows a real-time detection and localisation of multiple OC faults in all active power switches and clamp-diodes within one modulation period. Experimental results obtained for different operating conditions of the inverter demonstrate the applicability and performance of the proposed diagnostic approach.