Clinical Trial of an Experimental Cleaning Solution: Antibiofilm Effect and Integrity of a Silicone-based Denture Liner
2014; Jaypee Brothers; Volume: 15; Issue: 5 Linguagem: Inglês
10.5005/jp-journals-10024-1575
ISSN1526-3711
AutoresAntonio de Luna Malheiros Segundo, Marina Xavier Pisani, Cássio do Nascimento, Raphael Freitas de Souza, Helena de Freitas Oliveira Paranhos, Cláudia Helena Silva‐Lovato,
Tópico(s)Bacterial biofilms and quorum sensing
ResumoABSTRACT Aim This study evaluated the antibiofilm effect of an experimental solution of 2% Ricinus communis (R. communis) on a silicone-based denture liner by means of a randomized clinical trial, as well as the integrity of such liner following a cleansing regimen with such solution. Materials and methods About 30 complete denture wearers had their lower dentures relined with a silicone-based denture liner and randomly allocated to cleanse their dentures by means of: (A) a specific toothbrush for complete dentures and dentifrice; (B) soaking in an experimental 2% R. communis solution; and (C) association of A and B. Considered outcomes were biofilm coverage area (%), microbial counts by means of the deoxyribonucleic acid (DNA) checkerboard hybridization technique and physical integrity of the soft liner, assessed during a time interval of 60 days. Mean group values were compared by analysis of variance (ANOVA) and Tukey tests or generalized linear method (α = 0.05). Results The mechanical method presented the lowest biofilm percentage (1.45 ± 1.03) if compared to the chemical method (2.96 ± 1.98) and the associated one (2.71 ± 1.76). After 60 days (3.37 ± 2.04), biofilm accumulation was higher than at 15 days (1.28 ± 0.77) and 30 days (2.46 ± 1.54). The denture liner was less deteriorated and kept its physical integrity when the mechanical method was applied. The chemical method presented higher effectiveness against microorganisms, including some Candida species. Conclusion The 2% R. communis solution presented stronger antimicrobial capacity than brushing on a silicone-based denture liner after immersion. However, it was not superior to the mechanical method in preserving the physical integrity of the material and in biofilm removal. Clinical significance Soft denture liners hygiene is a very important issue and not conclusive in the literature. The experimental solution of 2% R. communis evaluated presented promising antimicrobial potential and should be more explored to be recommended as cleanser. How to cite this article de Luna Malheiros Segundo A, Pisani MX, do Nascimento C, Souza RF, de Freitas Oliveira Paranhos H, Silva-Lovato CH. Clinical Trial of an Experimental Cleaning Solution: Antibiofilm Effect and Integrity of a Silicone-based Denture Liner. J Contemp Dent Pract 2014;15(5):534-542.
Referência(s)