The Effect of Testing Distance on Intraocular Lens Power Calculation
2014; Slack Incorporated (United States); Volume: 30; Issue: 11 Linguagem: Inglês
10.3928/1081597x-20141021-01
ISSN1938-2391
AutoresMichael J. Simpson, W. N. Charman,
Tópico(s)Corneal surgery and disorders
ResumoLetter to the EditorThe Effect of Testing Distance on Intraocular Lens Power Calculation Michael J. Simpson, PhD, , PhD W. Neil Charman, PhD, , PhD Michael J. Simpson, PhD and W. Neil Charman, PhD Journal of Refractive Surgery, 2014;30(11):726Published Online:October 21, 2014https://doi.org/10.3928/1081597X-20141021-01Cited by:19PDFView Full Text ToolsAdd to favoritesDownload CitationsTrack Citations ShareShare onFacebookTwitterLinkedInRedditEmail SectionsMore"The Effect of Testing Distance on Intraocular Lens Power Calculation." Journal of Refractive Surgery, 30(11), p. 7261.Olsen T. Calculation of intraocular lens power: a review. Acta Ophthalmol Scand. 2007; 85:472–485.10.1111/j.1755-3768.2007.00879.x Crossref MedlineGoogle Scholar2.ULIB - the User Group for Laser Interference Biometry. http://www.augenklinik.uni-wuerzburg.de/ulib/. Updated July 17, 2014. Google Scholar3.Duke-Elder S, Abrams D. System of Ophthalmology, Vol. V: Ophthalmic Optics and Refraction. London: Kimpton; 1970:417–450. Google Scholar4.International Organization for Standardization. ISO 11979-9: Ophthalmic implants - intraocular lenses - Part 9: multifocal IOLs. Geneva, Switzerland; 2006. Google Scholar5.Thibos LN. Where is the optimum far-point for a presbyopic eye?J Refract Surg. 2008; 24:970–975. LinkGoogle Scholar Next article FiguresReferencesRelatedDetailsCited byKnutsson K, Savini G, Hoffer K, Lupardi E, Bertuzzi F, Taroni L, Schiano-Lomoriello D, Paganoni G and Rama P (2022) IOL Power Calculation in Eyes Undergoing Combined Descemet Membrane Endothelial Keratoplasty and Cataract Surgery, Journal of Refractive Surgery, 38:7, (435-442), Online publication date: 1-Jul-2022. Voytsekhivskyy O, Tutchenko L and Hipólito-Fernandes D (2022) Comparison of the Barrett Universal II, Kane and VRF-G formulas with existing intraocular lens calculation formulas in eyes with short axial lengths, Eye, 10.1038/s41433-021-01890-7 Fernández-Rosés J, Lamarca J, Hoffer K, Beltrán-Saiz A, Barraquer R and Savini G (2022) Color LED reflection topography: validation of equivalent keratometry reading for IOL power calculation in eyes with previous corneal myopic refractive surgery, Journal of Cataract and Refractive Surgery, 10.1097/j.jcrs.0000000000000709, 48:1, (32-36), Online publication date: 1-Jan-2022. Fernández-Rosés J, Lamarca J, Piñero D and Barraquer R (2021) Intraocular lens power calculation in virgin eyes: Accuracy of the Barrett Universal II formula and a Ray tracing software, European Journal of Ophthalmology, 10.1177/11206721211065552, (112067212110655) Li T, Reddy A, Stein J and Nallasamy N (2021) Ray tracing intraocular lens calculation performance improved by AI-powered postoperative lens position prediction, British Journal of Ophthalmology, 10.1136/bjophthalmol-2021-320283, (bjophthalmol-2021-320283) Wlaź A, Kustra A, Rozegnał-Madej A and Żarnowski T (2021) Intraocular lens power calculations in eyes with pseudoexfoliation syndrome, Scientific Reports, 10.1038/s41598-021-98675-5, 11:1, Online publication date: 1-Dec-2021. Sakai D, Hirami Y, Nakamura M and Kurimoto Y (2021) Accuracy of Intraocular Lens Power Calculation Formulas in Myopic Eyes with Target Refractions of Emmetropia and Intentional Myopia, Clinical Ophthalmology, 10.2147/OPTH.S342392, Volume 15, (4535-4541) Vaiano A, Hoffer K, Greco A, Greco A, D'Amico G, Pasqualitto V, Carlevale C and Savini G (2021) Accuracy of IOL Power Calculation Using the New Carlevale Sutureless Scleral Fixation Posterior Chamber IOL, Journal of Refractive Surgery, 37:7, (472-476), Online publication date: 1-Jul-2021. Simpson M (2021) Pre-clinical estimation of the intraocular lens A-constant, and its relationship to power, shape factor, and asphericity, Applied Optics, 10.1364/AO.426155, 60:19, (5662), Online publication date: 1-Jul-2021. Voytsekhivskyy O, Hoffer K, Savini G, Tutchenko L and fernandes D (2021) Clinical Accuracy of 18 IOL Power Formulas in 241 Short Eyes, Current Eye Research, 10.1080/02713683.2021.1933056 Li T, Stein J and Nallasamy N (2021) AI-powered effective lens position prediction improves the accuracy of existing lens formulas, British Journal of Ophthalmology, 10.1136/bjophthalmol-2020-318321, (bjophthalmol-2020-318321) Fernández J, Rodríguez-Vallejo M and Piñero D (2021) Re: Hoffer et al.: Update on intraocular lens power calculation study protocols: the better way to design and report clinical trials (Ophthalmology. 2020 Jul 9 [Epub ahead of print]), Ophthalmology, 10.1016/j.ophtha.2020.10.035, 128:3, (e17-e18), Online publication date: 1-Mar-2021. Nemeth G, Kemeny-Beke A and Modis L (2021) Comparison of accuracy of different intraocular lens power calculation methods using artificial intelligence, European Journal of Ophthalmology, 10.1177/1120672121994720, (112067212199472) Vaiano A, Hoffer K, Greco A, Greco A, D'Amico G, Pasqualitto V, Carlevale C and Savini G (2020) Long-term Outcomes and Complications of the New Carlevale Sutureless Scleral Fixation Posterior Chamber IOL, Journal of Refractive Surgery, 37:2, (126-132), Online publication date: 1-Feb-2021. Taroni L, Hoffer K, Barboni P, Schiano-Lomoriello D and Savini G (2020) Outcomes of IOL power calculation using measurements by a rotating Scheimpflug camera combined with partial coherence interferometry, Journal of Cataract and Refractive Surgery, 10.1097/j.jcrs.0000000000000361, 46:12, (1618-1623), Online publication date: 1-Dec-2020. Carmona-González D, Castillo-Gómez A, Palomino-Bautista C, Romero-Domínguez M and Gutiérrez-Moreno M (2020) Comparison of the accuracy of 11 intraocular lens power calculation formulas, European Journal of Ophthalmology, 10.1177/1120672120962030, (112067212096203) Hoffer K and Savini G (2020) Update on Intraocular Lens Power Calculation Study Protocols, Ophthalmology, 10.1016/j.ophtha.2020.07.005, Online publication date: 1-Jul-2020. Næser K and Savini G (2019) Accuracy of thick-lens intraocular lens power calculation based on cutting-card or calculated data for lens architecture, Journal of Cataract and Refractive Surgery, 10.1016/j.jcrs.2019.05.021, 45:10, (1422-1429), Online publication date: 1-Oct-2019. Koch D (2016) The Enigmatic Cornea and Intraocular Lens Calculations: The LXXIII Edward Jackson Memorial Lecture, American Journal of Ophthalmology, 10.1016/j.ajo.2016.08.020, 171, (xv-xxx), Online publication date: 1-Nov-2016. Request Permissions InformationCopyright 2014, SLACK IncorporatedPDF downloadThe authors have no financial or proprietary interest in the materials presented herein.
Referência(s)