Decentration of the Optical Zone: Centering on the Pupil versus the Coaxially Sighted Corneal Light Reflex in LASIK for Hyperopia
2003; Slack Incorporated (United States); Volume: 19; Issue: 4 Linguagem: Inglês
10.3928/1081-597x-20030701-17
ISSN1938-2391
AutoresBrian S. Boxer Wachler, Tommy S. Korn, Naveen Chandra, Franz K Michel,
Tópico(s)Glaucoma and retinal disorders
ResumoLetters to the EditorDecentration of the Optical Zone: Centering on the Pupil versus the Coaxially Sighted Corneal Light Reflex in LASIK for Hyperopia Brian S Boxer Wachler, MD, , , MD Tommy S Korn, MD, , , MD Naveen S Chandra, MD, , and , MD Franz K Michel, MD, , MD Brian S Boxer Wachler, MD , Tommy S Korn, MD , Naveen S Chandra, MD , and Franz K Michel, MD Journal of Refractive Surgery, 2013;19(4):464–465Published Online:July 01, 2003https://doi.org/10.3928/1081-597X-20030701-17Cited by:31PDFView Full Text ToolsAdd to favoritesDownload CitationsTrack Citations ShareShare onFacebookTwitterLinkedInRedditEmail SectionsMore"Decentration of the Optical Zone: Centering on the Pupil versus the Coaxially Sighted Corneal Light Reflex in LASIK for Hyperopia." Journal of Refractive Surgery, 19(4), pp. 464–4651. Uozato H, Guyton DL. Centering corneal surgical procedures. Am J Ophthalmol 1987;103:264-275. Google Scholar2. Bonds AB, MacLeod DIA. A displaced Stiles-Crawford effect associated with an eccentric pupil. Invest Ophthalmol Vis Sci. 1978;17:754-761 Google Scholar3. Pande M, Hillman JS. Optical zone centration in keratorefractive surgery: entrance pupil center, visual axis, coaxially sighted corneal reflex, or geometrie corneal center. Ophthalmology 1993;100: 1230-1237. Google Scholar4. Mulhern MG, Foley NA, O'Keefe M, Condon PI. Topographical analysis of ablation centration after excimer laser photorefractive keratectomy and laser in situ keratomileusis for high myopia. J Cataract Refract Surg 1997;23:488-494. Google Scholar5. Burian HM. The sensorial retinal relationships in comitant strabismus. Arch Ophthalmol 1947;37:336-340. Google Scholar Previous article Next article FiguresReferencesRelatedDetailsCited by Gharieb H, Shalaby H and Othman I (2022) Distribution of angle lambda and pupil offset as measured by combined Placido Scheimpflug Topography, International Ophthalmology, 10.1007/s10792-022-02394-3, 43:1, (121-130) Deng W, Fang Y, Lin S and Li Y (2022)(2022) Dynamic distribution and correlation analysis of the angle kappa in myopia patients undergoing femtosecond-assisted laser in situ keratomileusis, Medicine, 10.1097/MD.0000000000029425, 101:24, (e29425) Reinstein D, Archer T, Rowe E, Gobbe M and Vida R (2020) Distribution of Pupil Offset and Angle Kappa in a Refractive Surgery Preoperative Population of 750 Myopic, Emmetropic, and Hyperopic Eyes, Journal of Refractive Surgery, 37:1, (49-58), Online publication date: 1-Jan-2021. Zhang J, Wang Y, Chen X and Wu W (2020) Clinical outcomes of corneal refractive surgery comparing centration on the corneal vertex with the pupil center: a meta-analysis, International Ophthalmology, 10.1007/s10792-020-01506-1, 40:12, (3555-3563), Online publication date: 1-Dec-2020. Dong J, Zhang Y, Zhou J, Zhang S, Sun B, Tang M and Wang X (2019) Comparison of Corneal Power and Corneal Astigmatism of Different Diameter Zones Centered on the Pupil and Corneal Apex Using Scheimpflug Tomography, Cornea, 10.1097/ICO.0000000000002052, 39:1, (77-83), Online publication date: 1-Jan-2020. Adib-Moghaddam S, Soleyman-Jahi S, Moghaddam A, Hoorshad N, Tefagh G, Haydar A, Razi-Khoshroshahi M and Mosquera S (2018) Efficacy and safety of transepithelial photorefractive keratectomy, Journal of Cataract and Refractive Surgery, 10.1016/j.jcrs.2018.07.021, 44:10, (1267-1279), Online publication date: 1-Oct-2018. Gharaibeh A, Villanueva A, Mas D, Espinosa J and Alió J (2018) Corneal Stability following Hyperopic LASIK with Advanced Laser Ablation Profiles Analyzed by a Light Propagation Study, Journal of Ophthalmology, 10.1155/2018/3060939, 2018, (1-10), . Katz T (2016) Sources of Error in Corneal Refractive Surgery Complications in Corneal Laser Surgery, 10.1007/978-3-319-41496-6_5, (33-38), . Mohamed Mostafa E (2015) Effect of Flat Cornea on Visual Outcome after LASIK, Journal of Ophthalmology, 10.1155/2015/794854, 2015, (1-7), . Gharaee H, Shafiee M, Hoseini R, Abrishami M, Abrishami Y and Abrishami M (2014) Angle Kappa Measurements: Normal Values in Healthy Iranian Population Obtained With the Orbscan II, Iranian Red Crescent Medical Journal, 10.5812/ircmj.17873, 17:1 Chang D and Waring G (2014) The Subject-Fixated Coaxially Sighted Corneal Light Reflex: A Clinical Marker for Centration of Refractive Treatments and Devices, American Journal of Ophthalmology, 10.1016/j.ajo.2014.06.028, 158:5, (863-874.e2), Online publication date: 1-Nov-2014. Guilbert E, Saad A and Gatinel D (2014) AcuTarget Measurements: Repeatability and Comparison to OPD-Scan III, Journal of Refractive Surgery, 30:3, (180-185), Online publication date: 1-Mar-2014. Zarei-Ghanavati S, Gharaee H, Eslampour A, Abrishami M and Ghasemi-Moghadam S (2013) Angle kappa changes after photorefractive keratectomy for myopia, International Ophthalmology, 10.1007/s10792-013-9775-x, 34:1, (15-18), Online publication date: 1-Feb-2014. Domínguez-Vicent A, Monsálvez-Romín D, Pérez-Vives C, Ferrer-Blasco T and Montés-Micó R (2013) Measurement of angle Kappa with Orbscan II and Galilei G4: effect of accommodation, Graefe's Archive for Clinical and Experimental Ophthalmology, 10.1007/s00417-013-2509-y, 252:2, (249-255), Online publication date: 1-Feb-2014. Uthoff D, Pölzl M, Hepper D and Holland D (2012) A new method of cornea modulation with excimer laser for simultaneous correction of presbyopia and ametropia, Graefe's Archive for Clinical and Experimental Ophthalmology, 10.1007/s00417-012-1948-1, 250:11, (1649-1661), Online publication date: 1-Nov-2012. Arba Mosquera S and Ewering T (2012) New Asymmetric Centration Strategy Combining Pupil and Corneal Vertex Information for Ablation Procedures in Refractive Surgery: Theoretical Background, Journal of Refractive Surgery, 28:8, (567-575), Online publication date: 1-Aug-2012. Park C, Oh S and Chuck R (2012) Measurement of angle kappa and centration in refractive surgery, Current Opinion in Ophthalmology, 10.1097/ICU.0b013e3283543c41, 23:4, (269-275), Online publication date: 1-Jul-2012. Reinstein D, Archer T and Gobbe M (2011) Is Topography-guided Ablation Profile Centered on the Corneal Vertex Better Than Wavefront-guided Ablation Profile Centered on the Entrance Pupil?, Journal of Refractive Surgery, 28:2, (139-143), Online publication date: 1-Feb-2012. Luger M, Ewering T and Arba-Mosquera S (2012) 3-Month experience in presbyopic correction with bi-aspheric multifocal central presbyLASIK treatments for hyperopia and myopia with or without astigmatism, Journal of Optometry, 10.1016/j.optom.2011.12.001, 5:1, (9-23), Online publication date: 1-Jan-2012. Hashemi H, KhabazKhoob M, Yazdani K, Mehravaran S, Jafarzadehpur E and Fotouhi A (2010) Distribution of Angle Kappa Measurements with Orbscan II in a Population-Based Survey, Journal of Refractive Surgery, 26:12, (966-971), Online publication date: 1-Dec-2010. Arbelaez M, Vidal C and Arba Mosquera S (2010) Six-month clinical outcomes after hyperopic correction with the SCHWIND AMARIS Total-Tech laser, Journal of Optometry, 10.1016/S1888-4296(10)70029-7, 3:4, (198-205), Online publication date: 1-Oct-2010. Arba-Mosquera S, Arbelaez M and de Ortueta D (2010) Laser corneal refractive surgery in the twenty-first century: a review of the impact of refractive surgery on high-order aberrations (and vice versa), Journal of Modern Optics, 10.1080/09500340.2010.493243, 57:12, (1041-1074), Online publication date: 10-Jul-2010. (2009) Aberration-neutral Ablation Pattern in Hyperopic LASIK With the ESIRIS Laser Platform, Journal of Refractive Surgery, 25:2, (175-184), Online publication date: 1-Jan-2009. De Ortueta D and Haecker C (2018) Laser in Situ Keratomileusis for Mixed Astigmatism Using a Modified Formula for Bitoric Ablation, European Journal of Ophthalmology, 10.1177/112067210801800603, 18:6, (869-876), Online publication date: 1-Nov-2008. Basmak H, Sahin A, Yildirim N, Papakostas T and Kanellopoulos A (2007) Measurement of Angle Kappa With Synoptophore and Orbscan II in a Normal Population, Journal of Refractive Surgery, 23:5, (456-460), Online publication date: 1-May-2007.de Ortueta D and Schreyger F (2007) Centration on the Cornea Vertex Normal During Hyperopic Refractive Photoablation Using Videokeratoscopy, Journal of Refractive Surgery, 23:2, (198-200), Online publication date: 1-Feb-2007. Esquenazi S, Bui V and Bibas O (2006) Surgical Correction of Hyperopia, Survey of Ophthalmology, 10.1016/j.survophthal.2006.04.009, 51:4, (381-418), Online publication date: 1-Jul-2006. Chan C and Wachler B (2021) Centration Analysis of Ablation Over the Coaxial Corneal Light Reflex for Hyperopic LASIK, Journal of Refractive Surgery, 22:5, (467-471), Online publication date: 1-May-2006. Bueeler M, Iseli H, Jankov M and Mrochen M (2005) Treatment-induced shifts of ocular reference axes used for measurement centration, Journal of Cataract and Refractive Surgery, 10.1016/j.jcrs.2005.03.068, 31:10, (1986-1994), Online publication date: 1-Oct-2005. Qazi M, Roberts C, Mahmoud A and Pepose J (2005) Topographic and biomechanical differences between hyperopic and myopic laser in situ keratomileusis, Journal of Cataract and Refractive Surgery, 10.1016/j.jcrs.2004.10.043, 31:1, (48-60), Online publication date: 1-Jan-2005. Nepomuceno R, Boxer Wachler B, Kim J, Scruggs R and Sato M (2004) Laser in situ keratomileusis for hyperopia with the LADARVision 4000 with centration on the coaxially sighted corneal light reflex, Journal of Cataract and Refractive Surgery, 10.1016/j.jcrs.2003.10.031, 30:6, (1281-1286), Online publication date: 1-Jun-2004. Request Permissions InformationCopyright 2013, SLACK IncorporatedPDF download
Referência(s)