Screening for Atrial Fibrillation Using a Smartphone: Is There an App for That?
2016; Wiley; Volume: 5; Issue: 7 Linguagem: Inglês
10.1161/jaha.116.004000
ISSN2047-9980
Autores Tópico(s)Cardiac pacing and defibrillation studies
ResumoHomeJournal of the American Heart AssociationVol. 5, No. 7Screening for Atrial Fibrillation Using a Smartphone: Is There an App for That? Open AccessEditorialPDF/EPUBAboutView PDFView EPUBSections ToolsAdd to favoritesDownload citationsTrack citations ShareShare onFacebookTwitterLinked InMendeleyReddit Jump toOpen AccessEditorialPDF/EPUBScreening for Atrial Fibrillation Using a Smartphone: Is There an App for That? Ben Freedman, MBBS, PhD Ben FreedmanBen Freedman Heart Research Institute, Charles Perkins Centre, University of Sydney, New South Wales, Australia Department of Cardiology and Anzac Research Institute, Concord Hospital, Concord, New South Wales, Australia Originally published21 Jul 2016https://doi.org/10.1161/JAHA.116.004000Journal of the American Heart Association. 2016;5:e004000IntroductionAtrial fibrillation (AF) is a growing problem in cardiovascular disease and is associated with an increased risk of severe stroke, heart failure, and death. Indeed, recent stroke registries indicate that AF is associated with a third of all ischemic strokes.1 Anticoagulation with warfarin or the non‐vitamin K–dependent oral anticoagulants is extremely effective in reducing stroke and mortality, but between a quarter and a third of all AF‐related strokes occur in patients with stroke as the first manifestation of AF.2 Because unknown asymptomatic AF is common, occurring in 1.4% of those aged 65 or older on a single time point check for presence of AF,3 3% with patient‐activated recordings over 2 weeks,4 and even more if long‐term continuous recordings are used,5 it is intuitive that screening for AF and subsequent anticoagulant treatment should reduce the stroke burden related to AF.2 This is the basis of guideline recommendations to screen for AF in those aged ≥65.6Guidelines for screening for AF are based on a large‐cluster randomized controlled trial in general practice, of opportunistic pulse taking versus systematic screening with 12‐lead ECG or standard care. This study found that both opportunistic pulse taking and systematic screening detected similar numbers of unknown AF, and more than conventional care.7 But opportunistic pulse taking was less expensive than systematic 12‐lead electrocardiography, so opportunistic pulse taking followed by a 12‐lead ECG is now recommended as being cost‐effective.6 Unfortunately, pulse taking is not commonly performed in general practice, and if the heart rate is recorded during a visit, it is usually performed by an automated sphygmomanometer rather than by auscultation over the brachial artery, so an irregular pulse will go undetected.The advent of small devices that can diagnose AF automatically, based on either pulse irregularity8, 9 or rhythm analysis of a single‐lead handheld ECG,4, 10, 11 could change the cost‐benefit equation in favor of a more systematic approach to screening for AF either in the clinic or in the community (Figure).2, 12 In this context it is interesting to see the contribution of Chan et al13 in this issue of the Journal of the American Heart Association evaluating the diagnostic performance of a smartphone app. The app uses the smartphone flash/lightsource and camera to obtain a photoplethysmographic (PPG) recording of the pulse wave. This is the principle behind a number of popular mobile devices and apps used to measure heart rate, primarily for exercise and fitness.Download PowerPointFigure 1. Other devices to screen for atrial fibrillation. Top left, MyDiagnostick, which is a bar activated when held by left and right hands (lead 1 ECG). After recording for 1 minute, a green light indicates normal rhythm, a red light AF. The device can be connected by a cable to a PC to view the recordings, which have a date and time stamp only. Top right, Zenicor handheld ECG. Thumbs of each hand placed on the gray button electrodes on each side for 30 seconds generate a lead 1 ECG. There is no diagnosis or ECG trace on the device, which transmits wirelessly via the mobile network to a central data base with arrhythmia detection of ECG traces, viewable by the physician. Bottom left, Microlife sphygmomanometer. This is a standard oscillometric BP device that uses pulse wave irregularity to diagnose AF. An immediate diagnosis is given, but AF diagnosis on 2 of 3 readings is required before a diagnosis is confirmed. Bottom center and right, AliveCor (now Kardia) miniaturized ECG device with 2 silver electrodes held by fingers of right and left hands. It is usually stuck to the back of an android or iOS smartphone. Recording is activated by holding the device, which transmits to the smartphone via the microphone and app. The ECG is displayed on the smartphone, with automated AF diagnosis after 30 seconds of recording, and also transmitted to a central website or accessed by or emailed to the physician.The additional step in this case is an algorithm to analyze the regularity of the pulse waves and diagnose AF or normal rhythm based on it. Similar algorithms are used in oscillometric sphygmomanometers, which produce a pulse wave signal and diagnose AF from the pattern using a similar algorithm.9 Even with the devices that use a hand‐held ECG to produce a single‐lead (lead I) rhythm strip, regularity of the RR intervals is one of the features that algorithms use to diagnose AF. ECG devices do have the advantage of also being able to examine P waves as well as QRS morphology to aid in discrimination from sinus rhythm with ventricular or atrial premature contractions, which also produce an irregular pulse. The QRS complex may also be a more precise signal than the pulse wave for rhythm algorithms. Unfortunately all of these devices are subject to noise and artifacts produced by movement of hands, fingers, and arms or electrical noise/interference from the smartphone or adjacent appliances. Some algorithms do attempt to compensate, but a noise‐free signal is crucial to provide optimal diagnostic accuracy, irrespective of the device or technology used. This is particularly important when devices are used by people with minimal or no training.Use of a smartphone PPG to diagnose AF is not new. It was first reported in 2012 and 2013 by a Massachusetts group in 76 patients with AF8: readings were taken before and after cardioversion. The algorithm calculated root mean square of successive pulse wave differences and Shannon entropy. A follow‐up study in 201614 used the same data plus some additional patients with ectopic beats and addition of a Poincaré plot adaptation to differentiate premature contractions, which pose problems for purely pulse‐based methods. They used 2 minutes of PPG recording and a post‐hoc algorithm analysis and reported high sensitivity and specificity for AF detection.In this journal13 the smartphone "Cardiio Rhythm" app was used to diagnose AF. The algorithm in the app utilized a support vector machine term to analyze lack of repeating patterns in 17.1 seconds of collected PPG pulse waveforms. The study population included just over 1000 ambulatory outpatients with testing performed in real time in a clinic. The algorithm required that 2 out of 3 17‐second pulse wave recordings were coded as AF before an AF diagnosis had been made, so the total time required was ≈1 minute of PPG recording (a similar requirement for 2 of 3 readings to show AF is used in the oscillometric BP devices9). The trained observers who supervised the recording in the study ensured that both the PPG recording and the sequentially recorded hand‐held single‐lead AliveCor ECG were of high quality. Those with an abnormality detected on either the PPG Cardiio Rhythm app or the ECG AliveCor app had a 12‐lead ECG recorded within 15 minutes, which was the standard for diagnosis of AF. Two cardiologists blinded to the data read the 30‐second ECG rhythm strips to provide the diagnosis standard for the remainder. Not having a 12‐lead ECG available for every PPG result is a potential study weakness, but those with no 12‐lead ECG required for diagnosis were negative for AF by both PPG and single‐lead ECG algorithms. Their ECG rhythm strips are therefore likely to be relatively easily diagnosed as sinus rhythm by cardiologists.The results indicated a sensitivity of 92.9% and specificity of 97.7% for AF diagnosis, which would be adequate for using the smartphone PPG app for screening. Given the widespread availability of smartphones, the authors conclude that the app would have the potential to enable widespread screening for AF in the community. Of course there are a number of caveats. Crucially, the study was supervised by trained personnel, who directed the patients to ensure high‐quality PPG and ECG recordings. This would not necessarily be the case if the app were used widely in the community. One of the main issues causing false‐positive Cardiio Rhythm results in the study, was movement artifact. Artifact is likely to be a much greater problem if large numbers of unsupervised recordings are made at home or work in each subject. Moreover, the final diagnosis in the study was checked by a near‐simultaneous handheld ECG followed by a 12‐lead ECG if required, but neither would be available if a pulse‐based PPG were used for AF screening. Transmission of the PPG waveform would not really help confirm an AF diagnosis, unlike ECG‐based devices, which can all store and transmit a diagnostic quality ECG rhythm strip, as used by the expert readers in the current study.13 Although motion and noise are also problems for algorithms in handheld ECG devices, part of the collected ECG is often analyzable by trained ECG readers who are able to view the transmitted waveforms.The Chan et al study13 used ambulatory patients from a general outpatient clinic aged ≥65 with hypertension and/or diabetes, a more relevant population for screening than the pre‐ and postcardioversion patients, and a relatively small number of additional patients selected on the basis of rhythm, used in the previous PPG studies.8, 14 The authors of the current study also used the AliveCor smartphone‐based hand‐held ECG as both a diagnostic standard (cardiologist diagnosis) and a comparator using the AliveCor AF smartphone algorithm. The latter yielded a lower sensitivity but higher specificity than the PPG app in this study. In fact, the sensitivity of 71.4% was substantially lower than that in the initial studies that validated an AF detection algorithm in the clinic and then tested it in community use (sensitivity 98% in the initial clinic study10 and 98.5% in the larger community study conducted in pharmacies15) (Table). However, a similar lower sensitivity of 78.9% was reported in a recent study in hospitalized geriatric ward patients after exclusion of patients with implanted pacemaker devices, and even lower in cardiology ward inpatients.16 In the current study13 the Cardiio Rhythm PPG specificity was 97.7%, and the contemporaneous AliveCor ECG specificity was very high (99.4%, Table). Specificity was lower in previous AliveCor studies (97% clinic,10 91.4% community15 in the original AliveCor ECG studies, and 97.9% in the Desteghe et al study16). The principal reason for the difference in sensitivity between the original and more recent AliveCor studies is an intentional algorithm change down the receiver operator curve by the company favoring specificity over sensitivity.17 The rationale for this change is that the device is sold primarily to the public, who may not seek a physician or specialist overread. Additionally, for the Desteghe et al study,16 the AliveCor algorithm version contained a bug that necessitated a product recall in the United States during the course of the study but was not announced in Belgium, where the device was neither sold nor approved.17Table 1. Summary of Sensitivity and Specificity of CardiioRhythm PPG, AliveCor ECG, and MyDiagnostick ECGStudy, Device/Algorithm, PopulationnSensitivitySpecificityChan et al,13 Cardiio Rhythm PPG, outpatient101392.9%97.7%Chan et al,13 AliveCor ECG, outpatient101371.4%99.4%Lau et al,10 AliveCor ECG, outpatient and inpatient20498%97%Lowres et al,15 AliveCor ECG, community pharmacy100098.5%91.4%Desteghe et al,16 AliveCor ECG, inpatient geriatric11378.9%97.9%Desteghe et al,16 MyDiagnostick ECG, inpatient geriatric11389.5%95.7%John Wiley & Sons, LtdThere is always a trade‐off between sensitivity and specificity in setting algorithm diagnostic criteria. For physician or health practitioner use in screening for AF, very high sensitivity is required to pick up every person with unknown AF. This will of necessity reduce specificity. For an ECG‐based device with an immediate high‐quality ECG image, instant verification is possible, whereas for a PPG device, verification requires a sequential ECG. For health professional use of ECG‐based devices for screening, higher sensitivity will be required than documented in the current study13 for the AliveCor algorithm. This would necessitate reversion to the original algorithm with very high sensitivity but lower specificity. Essentially a health professional screening version of the AliveCor app is required for this device if it is to be used for AF screening.For screening in the community or for personal use, a drop in sensitivity may be a necessary trade‐off to achieve very high specificity. This is particularly important if large numbers of people are screened or when multiple recordings are requested in each person, as might be the case with a PPG app. In this situation even small reductions in specificity could lead to very large numbers of false‐positive results, which would require verification with a separate ECG.Ultimately for the diagnosis of AF, an ECG will be required. This is the reason for the class 1 recommendation in guidelines18: "Electrocardiographic documentation is recommended to establish the diagnosis of AF." Therefore, AF screening workflow using any automated pulse‐detection method, be it smartphone PPG or BP oscillometry, needs to factor in a mechanism for ECG verification. Verification will take time, involve logistic difficulties, and of course cost more. If hand‐held ECGs are used to screen for AF, the cost of expert verification of the ECG signal must also be factored in, although having an ECG trace available immediately is an advantage. The Chan et al study13 examined the net reclassification index (NRI), of the Cardiio Rhythm PPG algorithm over the AliveCor ECG algorithm, which would be appropriate only if the PPG were used as a second test following a hand‐held ECG test, which is highly unlikely and not the sequence of testing used in the study itself.The best device for the purpose of AF detection for screening or diagnosis will need to be individualized to the situation and the healthcare system. It will be important to optimize sensitivity for AF detection while preserving specificity, to reduce the workload and expense caused by false‐positive readings, and better noise detection and cancellation algorithms to reduce false positives. Adequate instruction in use of devices or apps is crucial to optimal performance. There cannot be a "one size fits all" solution for AF screening, and it is useful to have an addition to the diagnostic armamentarium, provided all are aware of the pitfalls as well as the advantages of the technique. Importantly, when deciding on devices for performing mass screening for AF, caveat emptor.DisclosuresB.F. received research grants to conduct investigator‐initiated studies from BMS/Pfizer, Bayer Pharma, and Boehringer‐Ingelheim and was a consultant for Bayer Pharma, BMS/Pfizer, Boehringer‐Ingelheim, Servier, Astra‐Zeneca, and Gilead, and speaker for Bayer Pharma, BMS/Pfizer, AstraZeneca. AliveCor provided ECG cases for screening studies, including some before the devices had been approved in any jurisdiction, but no funding.Footnotes*Correspondence to: Ben Freedman, MBBS, PhD, FRACP, FCSANZ, FACC, FESC, FAHA, Heart Research Institute, Level 3E D17, Charles Perkins Centre, University of Sydney, Sydney, New South Wales 2006, Australia. E‐mail: ben.[email protected]edu.auThe opinions expressed in this article are not necessarily those of the editors or of the American Heart Association.References1 Friberg L, Rosenqvist M, Lindgren A, Terent A, Norrving B, Asplund K. High prevalence of atrial fibrillation among patients with ischemic stroke. Stroke. 2014; 45:2599–2605.LinkGoogle Scholar2 Freedman SB, Lowres N. Asymptomatic atrial fibrillation. The case for screening to prevent stroke. JAMA. 2015; 314:1911–1912.CrossrefMedlineGoogle Scholar3 Lowres N, Neubeck L, Redfern J, Freedman SB. Screening to identify unknown atrial fibrillation. A systematic review. Thromb Haemost. 2013; 110:213–222.CrossrefMedlineGoogle Scholar4 Svennberg E, Engdahl J, Al‐Khalili F, Friberg L, Frykman V, Rosenqvist M. Mass screening for untreated atrial fibrillation: the STROKESTOP Study. Circulation. 2015; 131:2176–2184.LinkGoogle Scholar5 Healey JS, Connolly SJ, Gold MR, Israel CW, Van Gelder IC, Capucci A, Lau CP, Fain E, Yang S, Bailleul C, Morillo CA, Carlson M, Themeles E, Kaufman ES, Hohnloser SH. Subclinical atrial fibrillation and the risk of stroke. N Engl J Med. 2012; 366:120–129.CrossrefMedlineGoogle Scholar6 Camm AJ, Lip GY, De Caterina R, Savelieva I, Atar D, Hohnloser SH, Hindricks G, Kirchhof P; Guidelines ESCCfP . 2012 focused update of the ESC guidelines for the management of atrial fibrillation: an update of the 2010 ESC guidelines for the management of atrial fibrillation. Developed with the special contribution of the European Heart Rhythm Association. Eur Heart J. 2012; 33:2719–2747.CrossrefMedlineGoogle Scholar7 Fitzmaurice DA, Hobbs FDR, Jowett S, Mant J, Murray ET, Holder R, Raftery JP, Bryan S, Davies M, Lip GYH, Allan TF. Screening versus routine practice in detection of atrial fibrillation in patients aged 65 or over: cluster randomised controlled trial. BMJ. 2007; 335:383.CrossrefMedlineGoogle Scholar8 McManus DD, Lee J, Maitas O, Esa N, Pidikiti R, Carlucci A, Harrington J, Mick E, Chon KH. A novel application for the detection of an irregular pulse using an iPhone 4S in patients with atrial fibrillation. Heart Rhythm. 2013; 10:315–319.CrossrefMedlineGoogle Scholar9 Wiesel J, Arbesfeld B, Schechter D. Comparison of the Microlife blood pressure monitor with the Omron blood pressure monitor for detecting atrial fibrillation. Am J Cardiol. 2014; 114:1046–1048.CrossrefMedlineGoogle Scholar10 Lau JK, Lowres N, Neubeck L, Brieger DB, Sy RW, Galloway CD, Albert DE, Freedman SB. iPhone ECG application for community screening to detect silent atrial fibrillation: a novel technology to prevent stroke. Int J Cardiol. 2013; 165:193–194.CrossrefMedlineGoogle Scholar11 Tieleman RG, Plantinga Y, Rinkes D, Bartels GL, Posma JL, Cator R, Hofman C, Houben RP. Validation and clinical use of a novel diagnostic device for screening of atrial fibrillation. Europace. 2014; 16:1291–1295.CrossrefMedlineGoogle Scholar12 Lowres N, Neubeck L, Freedman SB. Can screening for atrial fibrillation be implemented at scale?Europace. 2016; doi:10.1093/europace/euw030. Available at: http://europace.oxfordjournals.org/content/early/2016/03/02/europace.euw030. Accessed July 8, 2016.CrossrefMedlineGoogle Scholar13 Chan PH, Wong CK, Poh YC, Pun L, Leung WWC, Wong YF, Wong MMY, Poh MZ, Chu DWS, Siu CW. Diagnostic performance of a smartphone‐based photoplethysmographic application for atrial fibrillation screening in a primary care setting. J Am Heart Assoc. 2016; 5:e003428 doi: 10.1161/JAHA.116.003428.LinkGoogle Scholar14 McManus DD, Chong JW, Soni A, Saczynski JS, Esa N, Napolitano C, Darling CE, Boyer E, Rosen RK, Floyd KC, Chon KH. PULSESMART: pulse‐based arrhythmia discrimination using a novel smartphone application. J Cardiovasc Electrophysiol. 2016; 27:51–57.CrossrefMedlineGoogle Scholar15 Lowres N, Neubeck L, Salkeld G, Krass I, McLachlan AJ, Redfern J, Bennett AA, Briffa T, Bauman A, Martinez C, Wallenhorst C, Lau JK, Brieger DB, Sy RW, Freedman SB. Feasibility and cost‐effectiveness of stroke prevention through community screening for atrial fibrillation using iPhone ECG in pharmacies. The SEARCH‐AF study. Thromb Haemost. 2014; 111:1167–1176.CrossrefMedlineGoogle Scholar16 Desteghe L, Raymaekers Z, Lutin M, Vijgen J, Dilling‐Boer D, Koopman P, Schurmans J, Vanduynhoven P, Dendale P, Heidbuchel H. Performance of handheld electrocardiogram devices to detect atrial fibrillation in a cardiology and geriatric ward setting. Europace. 2016; doi:10.1093/europace/euw025. Available at: http://europace.oxfordjournals.org/content/early/2016/02/17/europace.euw025. Accessed July 8, 2016.CrossrefMedlineGoogle Scholar17 Albert DE. Letter on Desteghe et al. "Performance of handheld electrocardiogram devices to detect atrial fibrillation in a cardiology and a geriatric ward setting". Europace. In press.Google Scholar18 January CT, Wann LS, Alpert JS, Calkins H, Cigarroa JE, Cleveland JC, Conti JB, Ellinor PT, Ezekowitz MD, Field ME, Murray KT, Sacco RL, Stevenson WG, Tchou PJ, Tracy CM, Yancy CW; Members AATF . 2014 AHA/ACC/HRS guideline for the management of patients with atrial fibrillation: a report of the American College of Cardiology/American Heart Association Task Force on practice guidelines and the Heart Rhythm Society. Circulation. 2014; 130:e199–e267.LinkGoogle Scholar Previous Back to top Next FiguresReferencesRelatedDetailsCited By Bañeras J, Pariggiano I, Ródenas-Alesina E, Oristrell G, Escalona R, Miranda B, Rello P, Soriano T, Gordon B, Belahnech Y, Calabrò P, García-Dorado D, Ferreira-González I, Radua J and Romiti G (2022) Optimal opportunistic screening of atrial fibrillation using pulse palpation in cardiology outpatient clinics: Who and how, PLOS ONE, 10.1371/journal.pone.0266955, 17:4, (e0266955) Gill S, Bunting K, Sartini C, Cardoso V, Ghoreishi N, Uh H, Williams J, Suzart-Woischnik K, Banerjee A, Asselbergs F, Eijkemans M, Gkoutos G and Kotecha D (2022) Smartphone detection of atrial fibrillation using photoplethysmography: a systematic review and meta-analysis, Heart, 10.1136/heartjnl-2021-320417, (heartjnl-2021-320417) Polidori M, Alves M, Bahat G, Boureau A, Ozkok S, Pfister R, Pilotto A, Veronese N and Bo M (2021) Atrial fibrillation: a geriatric perspective on the 2020 ESC guidelines, European Geriatric Medicine, 10.1007/s41999-021-00537-w, 13:1, (5-18), Online publication date: 1-Feb-2022. Tuboly G, Kozmann G, Kiss O and Merkely B (2021) Atrial fibrillation detection with and without atrial activity analysis using lead-I mobile ECG technology, Biomedical Signal Processing and Control, 10.1016/j.bspc.2021.102462, 66, (102462), Online publication date: 1-Apr-2021. Lee K, Kim J, Choi H and Nam Y (2021) Detection of Atrial Fibrillation in Short-Lead Electrocardiogram Recordings Obtained using a Smart Scale, Journal of Electrical Engineering & Technology, 10.1007/s42835-020-00631-2, 16:2, (1109-1118), Online publication date: 1-Mar-2021. Hindricks G, Potpara T, Dagres N, Arbelo E, Bax J, Blomström-Lundqvist C, Boriani G, Castella M, Dan G, Dilaveris P, Fauchier L, Filippatos G, Kalman J, La Meir M, Lane D, Lebeau J, Lettino M, Lip G, Pinto F, Thomas G, Valgimigli M, Van Gelder I, Van Putte B, Watkins C, Kirchhof P, Kühne M, Aboyans V, Ahlsson A, Balsam P, Bauersachs J, Benussi S, Brandes A, Braunschweig F, Camm A, Capodanno D, Casadei B, Conen D, Crijns H, Delgado V, Dobrev D, Drexel H, Eckardt L, Fitzsimons D, Folliguet T, Gale C, Gorenek B, Haeusler K, Heidbuchel H, Iung B, Katus H, Kotecha D, Landmesser U, Leclercq C, Lewis B, Mascherbauer J, Merino J, Merkely B, Mont L, Mueller C, Nagy K, Oldgren J, Pavlović N, Pedretti R, Petersen S, Piccini J, Popescu B, Pürerfellner H, Richter D, Roffi M, Rubboli A, Scherr D, Schnabel R, Simpson I, Shlyakhto E, Sinner M, Steffel J, Sousa-Uva M, Suwalski P, Svetlosak M, Touyz R, Dagres N, Arbelo E, Bax J, Blomström-Lundqvist C, Boriani G, Castella M, Dan G, Dilaveris P, Fauchier L, Filippatos G, Kalman J, La Meir M, Lane D, Lebeau J, Lettino M, Lip G, Pinto F, Neil Thomas G, Valgimigli M, Van Gelder I, Watkins C, Delassi T, Sisakian H, Scherr D, Chasnoits A, Pauw M, Smajić E, Shalganov T, Avraamides P, Kautzner J, Gerdes C, Alaziz A, Kampus P, Raatikainen P, Boveda S, Papiashvili G, Eckardt L, Vassilikos V, Csanádi Z, Arnar D, Galvin J, Barsheshet A, Caldarola P, Rakisheva A, Bytyçi I, Kerimkulova A, Kalejs O, Njeim M, Puodziukynas A, Groben L, Sammut M, Grosu A, Boskovic A, Moustaghfir A, Groot N, Poposka L, Anfinsen O, Mitkowski P, Cavaco D, Siliste C, Mikhaylov E, Bertelli L, Kojic D, Hatala R, Fras Z, Arribas F, Juhlin T, Sticherling C, Abid L, Atar I, Sychov O, Bates M and Zakirov N (2020) 2020 ESC Guidelines for the diagnosis and management of atrial fibrillation developed in collaboration with the European Association for Cardio-Thoracic Surgery (EACTS), European Heart Journal, 10.1093/eurheartj/ehaa612, 42:5, (373-498), Online publication date: 1-Feb-2021. Cunha S, Antunes E, Antoniou S, Tiago S, Relvas R, Fernandez-Llimós F and Alves da Costa F (2020) Raising awareness and early detection of atrial fibrillation, an experience resorting to mobile technology centred on informed individuals, Research in Social and Administrative Pharmacy, 10.1016/j.sapharm.2019.08.036, 16:6, (787-792), Online publication date: 1-Jun-2020. Sološenko A, Petrėnas A, Paliakaitė B, Sörnmo L and Marozas V (2019) Detection of atrial fibrillation using a wrist-worn device, Physiological Measurement, 10.1088/1361-6579/ab029c, 40:2, (025003) Hochstadt A, Chorin E, Viskin S, Schwartz A, Lubman N and Rosso R (2019) Continuous heart rate monitoring for automatic detection of atrial fibrillation with novel bio-sensing technology, Journal of Electrocardiology, 10.1016/j.jelectrocard.2018.10.096, 52, (23-27), Online publication date: 1-Jan-2019. Tieleman R and Hemels M (2018) Mobile health: solution or a threat?, Netherlands Heart Journal, 10.1007/s12471-018-1206-1, 27:1, (16-17), Online publication date: 1-Jan-2019. Iftikhar Z, Lahdenoja O, Jafari Tadi M, Hurnanen T, Vasankari T, Kiviniemi T, Airaksinen J, Koivisto T and Pänkäälä M (2018) Multiclass Classifier based Cardiovascular Condition Detection Using Smartphone Mechanocardiography, Scientific Reports, 10.1038/s41598-018-27683-9, 8:1, Online publication date: 1-Dec-2018. Khalil M, Piccirilli M and Sengupta P (2018) Learning to think like Machines, Indian Heart Journal, 10.1016/j.ihj.2018.08.003, 70:4, (469-470), Online publication date: 1-Jul-2018. Lown M, Shah B, Corbett S, Yue A, Little P and Moore M (2018) Response to: 'Screening for atrial fibrillation in hospitalised geriatric patients' by Tavernier et al , Heart, 10.1136/heartjnl-2017-312672, 104:7, (624-624), Online publication date: 1-Apr-2018. De Ridder B, Van Rompaey B, Kampen J, Haine S and Dilles T (2018) Smartphone Apps Using Photoplethysmography for Heart Rate Monitoring: Meta-Analysis, JMIR Cardio, 10.2196/cardio.8802, 2:1, (e4) Petrėnas A, Marozas V and Sörnmo L (2018) Lead Systems and Recording Devices Atrial Fibrillation from an Engineering Perspective, 10.1007/978-3-319-68515-1_2, (25-48), . Fay M, Fitzmaurice D and Freedman B (2017) Screening of older patients for atrial fibrillation in general practice: Current evidence and its implications for future practice, European Journal of General Practice, 10.1080/13814788.2017.1374366, 23:1, (246-253), Online publication date: 2-Oct-2017. Freedman B, Camm J, Calkins H, Healey J, Rosenqvist M, Wang J, Albert C, Anderson C, Antoniou S, Benjamin E, Boriani G, Brachmann J, Brandes A, Chao T, Conen D, Engdahl J, Fauchier L, Fitzmaurice D, Friberg L, Gersh B, Gladstone D, Glotzer T, Gwynne K, Hankey G, Harbison J, Hillis G, Hills M, Kamel H, Kirchhof P, Kowey P, Krieger D, Lee V, Levin L, Lip G, Lobban T, Lowres N, Mairesse G, Martinez C, Neubeck L, Orchard J, Piccini J, Poppe K, Potpara T, Puererfellner H, Rienstra M, Sandhu R, Schnabel R, Siu C, Steinhubl S, Svendsen J, Svennberg E, Themistoclakis S, Tieleman R, Turakhia M, Tveit A, Uittenbogaart S, Van Gelder I, Verma A, Wachter R, Yan B, Al Awwad A, Al-Kalili F, Berge T, Breithardt G, Bury G, Caorsi W, Chan N, Chen S, Christophersen I, Connolly S, Crijns H, Davis S, Dixen U, Doughty R, Du X, Ezekowitz M, Fay M, Frykman V, Geanta M, Gray H, Grubb N, Guerra A, Halcox J, Hatala R, Heidbuchel H, Jackson R, Johnson L, Kaab S, Keane K, Kim Y, Kollios G, Løchen M, Ma C, Mant J, Martinek M, Marzona I, Matsumoto K, McManus D, Moran P, Naik N, Ngarmukos T, Prabhakaran D, Reidpath D, Ribeiro A, Rudd A, Savalieva I, Schilling R, Sinner M, Stewart S, Suwanwela N, Takahashi N, Topol E, Ushiyama S, Verbiest van Gurp N, Walker N and Wijeratne T (2017) Screening for Atrial Fibrillation, Circulation, 135:19, (1851-1867), Online publication date: 9-May-2017. Sološenko A, Petrėnas A, Marozas V and Sörnmo L (2017) Modeling of the photoplethysmogram during atrial fibrillation, Computers in Biology and Medicine, 10.1016/j.compbiomed.2016.12.016, 81, (130-138), Online publication date: 1-Feb-2017. Orchard J, Lowres N, Freedman S, Ladak L, Lee W, Zwar N, Peiris D, Kamaladasa Y, Li J and Neubeck L (2016) Screening for atrial fibrillation during influenza vaccinations by primary care nurses using a smartphone electrocardiograph (iECG): A feasibility study, European Journal of Preventive Cardiology, 10.1177/2047487316670255, 23:2_suppl, (13-20), Online publication date: 1-Oct-2016. July 6, 2016Vol 5, Issue 7Article InformationMetrics © 2016 The Authors. Published on behalf of the American Heart Association, Inc., by Wiley Blackwell.This is an open access article under the terms of the Creative Commons Attribution‐NonCommercial License, which permits use, distribution and reproduction in any medium, provided the original work is properly cited and is not used for commercial purposes.https://doi.org/10.1161/JAHA.116.004000PMID: 27444507 Originally publishedJuly 21, 2016 Keywordsphotoplethysmographysmartphoneatrial fibrillationscreeningEditorialsPDF download SubjectsArrhythmiasAtrial FibrillationElectrocardiology (ECG)
Referência(s)