Artigo Acesso aberto Revisado por pares

Characterizing the Utility and Limitations of Repurposing an Open-Field Optical Imaging Device for Fluorescence-Guided Surgery in Head and Neck Cancer Patients

2016; Society of Nuclear Medicine and Molecular Imaging; Volume: 58; Issue: 2 Linguagem: Inglês

10.2967/jnumed.115.171413

ISSN

1535-5667

Autores

Lindsay S. Moore, Eben L. Rosenthal, Thomas K. Chung, Esther de Boer, Neel Patel, Andrew C. Prince, Melissa L. Korb, Erika M. Walsh, E. Scott Young, Todd M. Stevens, Kirk Withrow, Anthony B. Morlandt, Joshua Richman, William R. Carroll, Kurt R. Zinn, Jason M. Warram,

Tópico(s)

Photodynamic Therapy Research Studies

Resumo

The purpose of this study was to assess the potential of U.S. Food and Drug Administration–cleared devices designed for indocyanine green–based perfusion imaging to identify cancer-specific bioconjugates with overlapping excitation and emission wavelengths. Recent clinical trials have demonstrated potential for fluorescence-guided surgery, but the time and cost of the approval process may impede clinical translation. To expedite this translation, we explored the feasibility of repurposing existing optical imaging devices for fluorescence-guided surgery. Methods: Consenting patients ( n = 15) scheduled for curative resection were enrolled in a clinical trial evaluating the safety and specificity of cetuximab-IRDye800 (NCT01987375). Open-field fluorescence imaging was performed preoperatively and during the surgical resection. Fluorescence intensity was quantified using integrated instrument software, and the tumor-to-background ratio characterized fluorescence contrast. Results: In the preoperative clinic, the open-field device demonstrated potential to guide preoperative mapping of tumor borders, optimize the day of surgery, and identify occult lesions. Intraoperatively, the device demonstrated robust potential to guide surgical resections, as all peak tumor-to-background ratios were greater than 2 (range, 2.2–14.1). Postresection wound bed fluorescence was significantly less than preresection tumor fluorescence ( P < 0.001). The repurposed device also successfully identified positive margins. Conclusion : The open-field imaging device was successfully repurposed to distinguish cancer from normal tissue in the preoperative clinic and throughout surgical resection. This study illuminated the potential for existing open-field optical imaging devices with overlapping excitation and emission spectra to be used for fluorescence-guided surgery.

Referência(s)